• AS 2629-1983

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Separable insulated connectors for power distribution systems above 1 kV

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  04-07-1983

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 2629-1983 SEPARABLE INSULATED CONNECTORS FOR POWER DISTRIBUTION SYSTEMS ABOVE 1 kV
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1. SCOPE AND GENERAL
    6 - 1.1 SCOPE.
    6 - 1.2 REFERENCED DOCUMENTS.
    6 - 1.3 SERVICE CONDITIONS.
    7 - SECTION 2. DEFINITIONS
    7 - 2.1 APPLICATION OF SECTION.
    7 - 2.2 GENERAL TERMS.
    7 - 2.3 HARDWARE ITEMS.
    7 - 2.4 ELECTRICAL CHARACTERISTICS.
    12 - SECTION 3. RATINGS
    12 - 3.1 VOLTAGE RATINGS.
    12 - 3.2 RATED FREQUENCY.
    12 - 3.3 CURRENT RATINGS.
    13 - SECTION 4. DESIGN, CONSTRUCTION AND MARKING
    13 - 4.1 DESIGN.
    13 - 4.2 INTERCHANGEABILITY.
    13 - 4.3 OPERATING MEANS.
    13 - 4.4 SHIELDING.
    13 - 4.5 TEST POINTS.
    13 - 4.6 HOLD-DOWN BAILS.
    13 - 4.7 MARKING.
    25 - SECTION 5. PERFORMANCE
    25 - 5.1 BEHAVIOUR ON TEST AND IN SERVICE.
    25 - 5.2 OPERATING TEMPERATURE OF MATERIALS.
    26 - SECTION 6. CLASSIFICATION OF TESTS
    26 - 6.1 TYPE TESTS.
    26 - 6.2 ROUTINE TESTS.
    26 - 6.3 TESTS AT SITE.
    28 - SECTION 7. DETAILS OF TYPE TESTS
    28 - 7.1 DIELECTRIC TESTS.
    28 - 7.2 SHORT-CIRCUIT CURRENT-CARRYING CAPABILITY TEST.
    28 - 7.3 SWITCHING-CURRENT TESTS
    29 - 7.4 SHORT-CIRCUIT MAKING CURRENT TEST
    29 - 7.5 CONNECTOR ELBOW DISTORTION TEST FOR OFF-AXIS FORCE
    32 - 7.6 CURRENT-CYCLING TEST.
    33 - 7.7 CABLE PULL-OUT TEST.
    33 - 7.8 OPERATING FORCE TEST.
    33 - 7.9 OPERATING EYE TEST.
    33 - 7.10 TEST-POINT CAP MECHANICAL TEST.
    33 - 7.11 TEST-POINT ELECTRICAL TESTS.
    33 - 7.12 SHIELDING TEST.
    33 - 7.13 ACCELERATED SEALING LIFE TEST.

    Abstract - (Show below) - (Hide below)

    Applies to connectors, load-break up to 200 A and dead-break up to 1200 A, for use on power distribution systems at alternating voltages above 1 kV to 36 kV. Includes illustrations of system components and dimensioned drawings for the range of connection interfaces specified.

    Scope - (Show below) - (Hide below)

    This standard specifies requirements for load-break and dead-break separable insulated connectors and ancillary equipment for use on power distribution systems at alternating voltages above 1 kV.The standard applies to separable insulated connectors rated at not more than 1250 A.NOTE: Load-break connectors are available only for the lower current ratings. The purchaser should obtain information from manufacturers on available current ratings.

    General Product Information - (Show below) - (Hide below)

    Committee EL-007
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 1429.1:2006 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
    AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
    AS 1018-1985 Partial discharge measurements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective