• Shopping Cart
    There are no items in your cart

AS 2844.3-1986

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Milking machine installations - Mechanical tests

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Language(s)

English

Published date

01-01-1986

€32.89
Excluding VAT

1 - AS 2844.3-1986 MILKING MACHINE INSTALLATIONS - MECHANICAL TESTS
4 - PREFACE
4 - CONTENTS
5 - 1 SCOPE.
5 - 2 APPLICATION.
5 - 3 REFERENCED DOCUMENTS.
5 - 4 DEFINITIONS.
5 - 5 TEST EQUIPMENT.
5 - 5.1 General.
5 - 5.2 Measurement of vacuum level.
5 - 5.3 Measurement of air flow.
5 - 5.4 Measurement of pulsation chamber vacuum cycle
5 - 5.5 Measurement of pump speed.
5 - 5.6 Teatcup plugs.
5 - 6 MECHANICAL TESTS.
5 - 6.1 General.
6 - 6.2 Pulsation system (See AS 2844.2).
6 - 6.3 Double-chambered releaser.
6 - 6.4 Working vacuum and pump inlet vacuum
7 - 6.5 Vacuum pump capacity (See AS 2844.2).
7 - 6.6 Effective reserve (See AS 2844.2).
7 - 6.7 Regulator leakage (See AS 2844.2).
7 - 6.8 Vacuum gauge test (See AS 2844.2).
7 - 6.9 Air consumption of components.
8 - 6.10 Air leakage.
8 - 6.11 Air flow change (see AS 2844.2).
8 - 6.12 Vacuum drop (See AS 2844.2).
8 - 6.13 Vacuum at maximum air flow (See AS 2844.2).
8 - 7 TEST REPORT.
9 - APPENDIX A - FURTHER OPTIONAL TESTS
9 - A1 AIR ADMISSION TO CLUSTER.
9 - A2 STABILITY OF SYSTEM VACUUM.
9 - A3 MECHANICALLY OPERATED DIAPHRAGM RELEASER.
9 - A4 TESTING THE VACUUM SUPPLY AT THE CLUSTER.
11 - APPENDIX B - HEAD LOSSES IN AIRLINES AND FITTINGS
11 - B1 ‘VACUUM DROP’ IN AIRLINES DUE TO FRICTION.
11 - B2 FRICTION EQUIVALENTS OF FITTINGS.
12 - APPENDIX C - VISUAL FAULTS CHECK LIST
12 - SECTION 1: To be completed before milking machine is started. Comments
13 - SECTION 2: To be completed largely with machine operating.
15 - APPENDIX D1 - MACHINE TEST REPORT
17 - APPENDIX D2 - MILKING MACHINE TEST SUMMARY

Sets out procedures for carrying out mechanical tests on milking machines to verify that installations comply with the requirements specified in AS 2844.2, Construction and performance. May be used for testing new installations prior to acceptance and for periodic checking of machines for efficiency of operation. Also stipulates the accuracy requirements of measuring instruments and provides examples of the types of report forms which can be used to record tests results.

Committee
FT-028
DocumentType
Standard
ISBN
0 7262 4015 X
Pages
13
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This standard specifies mechanical tests for milking machine installations in order to verify compliance with the requirements of AS 2844.2. It also stipulates accuracy requirements for measuring instruments.NOTE: Examples of the types of report forms which can be used to record test results are given in Appendices.

AS 2844.1-1986 Milking machine installations - Glossary of terms
AS 2844.2-1986 Milking machine installations - Construction and performance

AS 2844.2-1986 Milking machine installations - Construction and performance

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.