• There are no items in your cart

AS 2879.7-1997

Current

Current

The latest, up-to-date edition.

Alumina Determination of trace elements - Wavelength dispersive X-ray fluorescence spectrometric method (Reconfirmed 2013)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-01-1997

€65.33
Excluding VAT

This Standard has been reconfirmed. To view or download the Reconfirmation Notice please click here.

1 - AS 2879.7-1997 ALUMINA - DETERMINATION OF TRACE ELEMENTS - WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRIC METHOD
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
7 - 3 PRINCIPLE
7 - 4 REAGENTS AND MATERIALS
7 - 4.1 Flux
7 - 4.2 Aluminium oxide
7 - 4.3 Sodium tetraborate
7 - 4.4 Silicon dioxide
7 - 4.5 Iron( III) oxide
7 - 4.6 Calcium carbonate
7 - 4.7 Titanium dioxide
7 - 4.8 Ammonium dihydrogen orthophosphate
7 - 4.9 Vanadium pentoxide
7 - 4.10 Zinc oxide
8 - 4.11 Manganese oxide
8 - 4.12 Gallium oxide
8 - 4.13 Potassium carbonate
8 - 4.14 Copper oxide
8 - 4.15 Chromium( III) oxide
8 - 4.16 Nickel( II) oxide (NiO),
8 - 5 APPARATUS
8 - 5.1 Crucible
8 - 5.2 Desiccator
8 - 5.3 Electric furnace
8 - 5.4 Mould
8 - 5.5 X-ray fluorescence spectrometer
8 - 5.6 Vibratory mill
8 - 5.7 Fusion equipment
8 - 6 SAMPLING AND SAMPLES
9 - 7 PROCEDURE
9 - 7.1 General
9 - 7.2 Preparation of calibration specimens
12 - 7.3 Preparation of sample
13 - 7.4 X-ray fluorescence measurement
15 - 8 CALCULATIONS
15 - 8.1 General
15 - 8.2 Calculation of net intensity
15 - 8.3 Comparison of duplicate measurements for the Al2O3 blanks and SCDs
16 - 8.4 Drift correction of measured intensities
16 - 8.5 Calculation of the calibration parameters
16 - 9 REPORTING OF RESULTS
17 - 10 PRECISION
17 - 11 TEST REPORT
18 - APPENDIX A - MINIMIZATION OF CONTAMINATION AND CARE OF PLATINUM WARE
18 - A1 REAGENTS AND INSTRUMENT
18 - A2 PLATINUM WARE
18 - A3 BLANK
19 - APPENDIX B - EXAMPLE OF INSTRUMENT OPTIMIZATION
19 - B1 SCOPE
19 - B2 COUNTING STRATEGY
20 - B3 SPECTRAL INTERFERENCE
25 - APPENDIX C - CALCULATION OF REAGENT MASSES FOR DIFFERENT SAMPLE/FLUX COMBINATIONS AND SCDs OMITTING SOME ELEMENTS
26 - APPENDIX D - PREPARATION OF A MONITOR DISC
27 - APPENDIX E INTERLABORATORY TEST PROGRAM ANALYSIS OF NBS 699, REDUCTION-GRADE ALUMINA, STANDARD REFERENCE MATERIAL

Sets out a wavelength dispersive X-ray fluorescence spectrometric method for the analysis of aluminium oxide for trace amounts of any or all of the following elements: sodium, silicon, iron, calcium, titanium, phosphorous, vanadium, zinc, manganese, gallium, potassium, copper, chromium and nickel, expressed as the oxides on an as-received basis.

Committee
MN/9
DocumentType
Standard
ISBN
0 7337 0796 3
Pages
22
ProductNote
Reconfirmed 18-07-2013
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out a wavelength dispersive X-ray fluorescence spectrometric method for the analysis of aluminium oxide for trace amounts of any or all of the following elements: sodium, silicon, iron, calcium, titanium, phosphorus, vanadium, zinc, manganese, gallium, potassium, copper, chromium and nickel (expressed as the oxides Na2O, SiO2, Fe2O3, CaO, TiO2, P2O5, V2O5, ZnO, MnO, Ga2O3, K2O, CuO, Cr2O3and NiO on an as-received basis).The method is applicable to smelting-grade aluminium oxide. The concentration range covered for each of the components is given in Table 1.

First published as AS 2879.7-1997.

09/30196939 DC : 0 BS ISO 12315 - ALUMINIUM OXIDE PRIMARILY USED FOR PRODUCTION OF ALUMINIUM - METHOD FOR CALCULATING THE AL[2]O[3] CONTENT OF SMELTER-GRADE ALUMINA
BS ISO 12315:2010 Aluminium oxide primarily used for production of aluminium. Method for calculating the Al<sub>2</sub>O<sub>3</sub> content of smelter-grade alumina
AS 2706-2003 Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018)
ISO 12315:2010 Aluminium oxide primarily used for production of aluminium — Method for calculating the Al2O3 content of smelter-grade alumina
AS 2706-1984 Numerical values - Rounding and interpretation of limiting values
AS 2508.8.013-1991 Safe storage and handling information card - Hydrofluoric acid (aqueous)
AS 2563-1996 Wavelength dispersive X-ray fluorescence spectrometers - Determination of precision
AS 2850-1986 Chemical analysis - Interlaboratory test programs - For determining precision of analytical method(s) - Guide to the planning and conduct

AS 2503.6-2007 Refractories and refractory materials - Chemical analysis Refractories, refractory mortars and silicate materials - Determination of major and minor elements - Wavelength dispersive X-ray fluorescence spectrometry using lithium borate fusion (Reconfirmed 2017)
AS 2879.11-2004 Alumina Guide to reporting Al2O3 content of smelter-grade alumina (Reconfirmed 2016)
SA TR 2.27-2013 Certified reference material Alumina - Preparation and certification of ASCRM 027

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.