AS 3010.1-1987

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical installations - Supply by generating set Internal combustion engine driven sets

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

25-05-2024

Superseded by

AS/NZS 3010:2005

Published date

01-01-1987

€32.89
Excluding VAT

1 - AS 3010.1-1987 ELECTRICAL INSTALLATIONS-SUPPLY BY GENERATING SET - INTERNAL COMBUSTION ENGINE DRIVEN SET
4 - PREFACE
5 - CONTENTS
6 - SECTION 1. SCOPE AND GENERAL
6 - 1.1 SCOPE.
6 - 1.2 APPLICATION.
6 - 1.3 REFERENCED DOCUMENTS.
6 - 1.4 DEFINITIONS.
6 - 1.4.1 Generating set
6 - 1.4.2 Emergency supply system
6 - 1.4.3 Independent supply system
6 - 1.4.4 Standby supply system
7 - SECTION 2. GENERAL REQUIREMENTS FOR THE INSTALLATION OF GENERATING SETS
7 - 2.1 GENERAL.
7 - 2.2 LOCATION.
7 - 2.3 MECHANICAL AND THERMAL PROTECTION.
7 - 2.3.1 Protection from mechanical damage.
7 - 2.3.2 Protection from moving parts.
7 - 2.3.3 Protection from hot parts.
7 - 2.3.4 Protection from fuel leakage.
7 - 2.4 ELECTRICAL PROTECTION.
7 - 2.4.1 General.
7 - 2.4.2 Protection from live parts.
7 - 2.4.3 Insulating materials.
7 - 2.4.4 Overcurrent protection.
8 - 2.5 CONTROL.
8 - 2.5.1 General.
8 - 2.5.2 Speed control of prime movers.
8 - 2.5.3 Isolating devices.
8 - 2.5.4 Isolation from Supply Authority system.
8 - 2.5.5 Changeover facilities.
10 - 2.5.6 Synchronization.
10 - 2.6 EARTHING AND BONDING.
10 - 2.6.1 Generating set bonding system.
10 - 2.6.2 Connection windings.
10 - 2.6.3 Generating sets used with fixed installations with an earthing system.
10 - 2.6.4 Generating set used with other arrange-ments.
10 - 2.7 SWITCHBOARDS AND CONTROL PANELS.
10 - 2.7.1 Arrangement of equipment.
10 - 2.7.2 Insulating panels.
10 - 2.7.3 Clearances and creepage distances.
10 - 2.8 SWITCHGEAR.
10 - 2.8.1 Rating.
11 - 2.8.2 Provisions for securing switches.
11 - 2.8.3 Indication of switch position.
11 - 2.8.4 High voltage switchgear containing flammable liquid dielectrics.
11 - 2.9 BA TTERIES AND BATTERY CHARGING.
11 - 2.10 LIGHTNING PROTECTION SYSTEMS.
12 - SECTION 3. ADDITIONAL REQUIREMENTS FOR PERMANENTLY CONNECTED GENERATING SETS
12 - 3.1 GENERAL.
12 - 3.2 LOCATION.
12 - 3.2.1 General.
12 - 3.2.2 Access space for generating sets.
12 - 3.2.3 Exit from generating set area.
12 - 3.2.4 Ventilation.
12 - 3.2.5 Lighting.
12 - 3.3 GUARDING OF LIVE PARTS.
12 - 3.3.1 General.
12 - 3.3.2 Walked-on surfaces.
12 - 3.3.3 Outdoor locations.
12 - 3.4 EARTHING OF HIGH VOLTAGE GENERATING SETS.
12 - 3.5 BATTERIES.
12 - 3.6 TRANSFORMERS.
12 - 3.6.1 Transformers and substations.
12 - 3.6.2 Earthing.
12 - 3.6.3 Instrument transformers.
12 - 3.7 ADDITIONAL REQUIREMENTS FOR GENERATING SETS FOR EMERGENCY SUPPLY SYSTEMS.
12 - 3.7.1 General.
13 - 3.7.2 Type.
13 - 3.7.3 Overcurrent protection.
13 - 3.7.4 Paralleling sources of emergency supply.
13 - 3.7.5 Supply of other than safety services.
13 - 3.7.6 Automatic changeover to emergency supply.
13 - 3.7.7 Switchgear.
14 - SECTION 4. ADDITIONAL REQUIREMENTS FOR PLUG AND SOCKET-OUTLET CONNECTED GENERATING SETS
14 - 4.1 GENERAL.
14 - 4.2 BONDING AND EARTHING.
14 - 4.2.1 General.
14 - 4.2.2 Connection of generating set winding.
14 - 4.3 CONNECTION TO FIXED INSTALLA-TION.
14 - 4.3.1 General.
14 - 4.3.2 Enclosure of live parts.
14 - 4.3.3 Marking.
14 - 4.4 CONTROL OF SOCKET-OUTLETS.

Applies to the installation of electricity generating sets that are driven by internal combustion engines, and which are used for the supply of fixed electrical installations in buildings or items of electrical equipment.

Committee
EL-001
DocumentType
Standard
ISBN
0 7262 4778 2
Pages
9
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out the minimum safety requirements related to the use of generating sets for the supply of electricity at voltages normally exceeding 32 V a.c. or 115 V d.c.The Standard applies to electricity generating sets that are driven by internal combustion engines, and which are used for the supply of fixed electrical installations in buildings or items of electrical equipment.This Standard does not -(a) set out performance and constructional requirements for generating sets; or(b) specifically apply to specialized automatic sources of supply, e.g. no-break systems or generating sets belonging to Electricity Generating or Supply Authorities.NOTES:1. Requirements for the performance and construction of transportable generating sets up to 25 kW are given in AS 2790.2. Requirements for the design, installation and operation of emergency power supplies in hospitals are given in AS 3009.3. Attention is drawn to the fact that some Regulatory Authorities have requirements for limitation of noise and pollution generation.

Under Revision see DR 03312

AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
AS/NZS 3009:1998 Electrical installations - Emergency power supplies in hospitals
AS/NZS 3002:2002 Electrical installations - Shows and carnivals
AS 4509.2-2002 Stand-alone power systems - System design guidelines
AS 4509.3-1999 Stand-alone power systems Installation and maintenance
AS/NZS 4249:1994 Electrical safety practices - Film, video and television sites
AS/NZS 3012:2003 Electrical installations - Construction and demolition sites
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3012:1995 Electrical installations - Construction and demolition sites
AS 2790-1989 Electricity generating sets - Transportable (Up to 25 kW)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.