• AS 3010.1-1987

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electrical installations - Supply by generating set - Internal combustion engine driven sets

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s): 

    Published date:  01-01-1987

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 3010.1-1987 ELECTRICAL INSTALLATIONS-SUPPLY BY GENERATING SET - INTERNAL COMBUSTION ENGINE DRIVEN SET
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1. SCOPE AND GENERAL
    6 - 1.1 SCOPE.
    6 - 1.2 APPLICATION.
    6 - 1.3 REFERENCED DOCUMENTS.
    6 - 1.4 DEFINITIONS.
    6 - 1.4.1 Generating set
    6 - 1.4.2 Emergency supply system
    6 - 1.4.3 Independent supply system
    6 - 1.4.4 Standby supply system
    7 - SECTION 2. GENERAL REQUIREMENTS FOR THE INSTALLATION OF GENERATING SETS
    7 - 2.1 GENERAL.
    7 - 2.2 LOCATION.
    7 - 2.3 MECHANICAL AND THERMAL PROTECTION.
    7 - 2.3.1 Protection from mechanical damage.
    7 - 2.3.2 Protection from moving parts.
    7 - 2.3.3 Protection from hot parts.
    7 - 2.3.4 Protection from fuel leakage.
    7 - 2.4 ELECTRICAL PROTECTION.
    7 - 2.4.1 General.
    7 - 2.4.2 Protection from live parts.
    7 - 2.4.3 Insulating materials.
    7 - 2.4.4 Overcurrent protection.
    8 - 2.5 CONTROL.
    8 - 2.5.1 General.
    8 - 2.5.2 Speed control of prime movers.
    8 - 2.5.3 Isolating devices.
    8 - 2.5.4 Isolation from Supply Authority system.
    8 - 2.5.5 Changeover facilities.
    10 - 2.5.6 Synchronization.
    10 - 2.6 EARTHING AND BONDING.
    10 - 2.6.1 Generating set bonding system.
    10 - 2.6.2 Connection windings.
    10 - 2.6.3 Generating sets used with fixed installations with an earthing system.
    10 - 2.6.4 Generating set used with other arrange-ments.
    10 - 2.7 SWITCHBOARDS AND CONTROL PANELS.
    10 - 2.7.1 Arrangement of equipment.
    10 - 2.7.2 Insulating panels.
    10 - 2.7.3 Clearances and creepage distances.
    10 - 2.8 SWITCHGEAR.
    10 - 2.8.1 Rating.
    11 - 2.8.2 Provisions for securing switches.
    11 - 2.8.3 Indication of switch position.
    11 - 2.8.4 High voltage switchgear containing flammable liquid dielectrics.
    11 - 2.9 BA TTERIES AND BATTERY CHARGING.
    11 - 2.10 LIGHTNING PROTECTION SYSTEMS.
    12 - SECTION 3. ADDITIONAL REQUIREMENTS FOR PERMANENTLY CONNECTED GENERATING SETS
    12 - 3.1 GENERAL.
    12 - 3.2 LOCATION.
    12 - 3.2.1 General.
    12 - 3.2.2 Access space for generating sets.
    12 - 3.2.3 Exit from generating set area.
    12 - 3.2.4 Ventilation.
    12 - 3.2.5 Lighting.
    12 - 3.3 GUARDING OF LIVE PARTS.
    12 - 3.3.1 General.
    12 - 3.3.2 Walked-on surfaces.
    12 - 3.3.3 Outdoor locations.
    12 - 3.4 EARTHING OF HIGH VOLTAGE GENERATING SETS.
    12 - 3.5 BATTERIES.
    12 - 3.6 TRANSFORMERS.
    12 - 3.6.1 Transformers and substations.
    12 - 3.6.2 Earthing.
    12 - 3.6.3 Instrument transformers.
    12 - 3.7 ADDITIONAL REQUIREMENTS FOR GENERATING SETS FOR EMERGENCY SUPPLY SYSTEMS.
    12 - 3.7.1 General.
    13 - 3.7.2 Type.
    13 - 3.7.3 Overcurrent protection.
    13 - 3.7.4 Paralleling sources of emergency supply.
    13 - 3.7.5 Supply of other than safety services.
    13 - 3.7.6 Automatic changeover to emergency supply.
    13 - 3.7.7 Switchgear.
    14 - SECTION 4. ADDITIONAL REQUIREMENTS FOR PLUG AND SOCKET-OUTLET CONNECTED GENERATING SETS
    14 - 4.1 GENERAL.
    14 - 4.2 BONDING AND EARTHING.
    14 - 4.2.1 General.
    14 - 4.2.2 Connection of generating set winding.
    14 - 4.3 CONNECTION TO FIXED INSTALLA-TION.
    14 - 4.3.1 General.
    14 - 4.3.2 Enclosure of live parts.
    14 - 4.3.3 Marking.
    14 - 4.4 CONTROL OF SOCKET-OUTLETS.

    Abstract - (Show below) - (Hide below)

    Applies to the installation of electricity generating sets that are driven by internal combustion engines, and which are used for the supply of fixed electrical installations in buildings or items of electrical equipment.

    Scope - (Show below) - (Hide below)

    This Standard sets out the minimum safety requirements related to the use of generating sets for the supply of electricity at voltages normally exceeding 32 V a.c. or 115 V d.c.The Standard applies to electricity generating sets that are driven by internal combustion engines, and which are used for the supply of fixed electrical installations in buildings or items of electrical equipment.This Standard does not -(a) set out performance and constructional requirements for generating sets; or(b) specifically apply to specialized automatic sources of supply, e.g. no-break systems or generating sets belonging to Electricity Generating or Supply Authorities.NOTES:1. Requirements for the performance and construction of transportable generating sets up to 25 kW are given in AS 2790.2. Requirements for the design, installation and operation of emergency power supplies in hospitals are given in AS 3009.3. Attention is drawn to the fact that some Regulatory Authorities have requirements for limitation of noise and pollution generation.

    General Product Information - (Show below) - (Hide below)

    Committee EL-001
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    Under Revision see DR 03312

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
    AS/NZS 3009:1998 Electrical installations - Emergency power supplies in hospitals
    AS/NZS 3002:2002 Electrical installations - Shows and carnivals
    AS 4509.2-2002 Stand-alone power systems - System design guidelines
    AS 4509.3-1999 Stand-alone power systems - Installation and maintenance
    AS/NZS 4249:1994 Electrical safety practices - Film, video and television sites
    AS/NZS 3012:2003 Electrical installations - Construction and demolition sites
    AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS/NZS 3012:1995 Electrical installations - Construction and demolition sites
    AS 2790-1989 Electricity generating sets - Transportable (Up to 25 kW)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective