AS 3011.1-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

23-12-1991

Superseded date

23-03-2025

Superseded by

AS 3011.1:2019

€19.70
Excluding VAT
Summarise this standard

1 - AS 3011.1-1992 ELECTRICAL INSTALLATIONS-SECONDARY BATTERIES INSTALLED IN BUILDINGS - VENTED CELLS
4 - PREFACE
4 - CONTENTS
5 - SECTION 1 SCOPE AND GENERAL
5 - 1.1 SCOPE
5 - 1.2 REFERENCED DOCUMENTS
5 - 1.3 DEFINITIONS
5 - 1.3.1 Accessible, readily
5 - 1.3.2 Authorized person
5 - 1.3.3 Battery
5 - 1.3.4 Battery enclosure
5 - 1.3.5 Battery room
5 - 1.3.6 Cell
5 - 1.3.7 Charging
5 - 1.3.8 May
5 - 1.3.9 Monobloc battery
5 - 1.3.10 Nominal voltage
5 - 1.3.11 Shall
5 - 1.3.12 Should
6 - SECTION 2 GENERAL REQUIREMENTS
6 - 2.1 GENERAL
6 - 2.1.1 Hydrogen emission
6 - 2.1.2 Alarms
6 - 2.1.3 Battery accommodation
6 - 2.1.4 Arrangement of cells
6 - 2.1.5 Ventilation
6 - 2.2 BATTERY ROOM REQUIREMENTS
6 - 2.2.1 General
6 - 2.2.2 Battery room layout and floor area
7 - 2.2.3 Take-off battery terminals and outgoing busbars and cables
7 - 2.2.4 Inter-tier and inter-row connections
7 - 2.2.5 Inter-cell connectors
7 - 2.2.6 Location of luminaires
7 - 2.2.7 Location of general purpose outlets
7 - 2.3 BATTERY ENCLOSURE REQUIREMENTS
7 - 2.3.1 Enclosure construction
7 - 2.3.2 Take-off battery terminals and outgoing busbars and cables
7 - 2.3.3 Battery compartment circuits
8 - SECTION 3 INSTALLATION
8 - 3.1 GENERAL
8 - 3.2 CONNECTIONS
8 - 3.3 PROTECTION
8 - 3.3.1 Overcurrent protection
8 - 3.3.2 Warning notices
8 - 3.3.3 Switchgear
8 - 3.3.4 Earth-leakage detection
8 - 3.3.5 Main isolating switch
8 - 3.3.6 Section isolating equipment
8 - 3.3.7 Fire safety and warning signs
9 - APPENDIX A - TYPICAL BATTERY ROOM LAYOUT (SHOWING MINIMUM CLEARANCES)

Specifies requirements for the installation of vented secondary batteries permanently installed in buildings.

Committee
EL-005
DocumentType
Standard
ISBN
0 7262 7305 8
Pages
6
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out requirements for the installation of vented secondary batteries with a nominal voltage exceeding 24 V and a capacity exceeding 10 A.h at the 1 h rate of discharge, permanently installed in or on buildings, structures or premises to ensure safety from fire and electric shock.AS 2676.1 provides guidance on the installation and maintenance of vented secondary batteries.This Standard covers vented cells only. The installation and maintenance of sealed cells are covered by AS 3011.2 and AS 2676.2.NOTE: Requirements specifically applicable to the design and installation of extra-low voltage (d.c.) power supplies that are used by telecommunications carriers in the provision of public telecommunications networks are given in AS 3015(Int)-1991, Electrical installations - Extra-low voltage (d.c.) power supplies in public telecommunications networks.

First published as part of AS 2676-1983.
AS 2676-1983 revised and redesignated in part as AS 3011-1987.
AS 3011-1987 revised and redesignated AS 3011.1-1990.
Second edition 1992.

⚠

A newer version of this standard is available.

View Current Edition