AS 3200.2.14-1992

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Approval and test specification - Medical electrical equipment Particular requirements for safety - Electroconvulsive therapy equipment

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Published date

15-05-1992

€45.79
Excluding VAT

1 - AS 3200.2.14-1992 APPROVAL AND TEST SPECIFICATION-MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY-ELECTROCONVU
4 - PREFACE
5 - CONTENTS
6 - SECTION ONE - GENERAL
6 - 1. Scope and object
6 - 2. Terminology and definitions
6 - 3. General requirements
7 - 4. General requirementsf or tests
7 - 5. Classification
7 - 6. Identification, marking and documents
8 - 7. Power input
8 - SECTION TWO - ENVIRONMENTAL CONDITIONS
8 - 12. Single fault condition
8 - SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
8 - 14. Requirements related to classification
9 - 19. Continuous leakage currents and patient auxiliary currents
9 - 20. Dielectric strength
10 - SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
10 - SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION
10 - SECTION SIX - PROTECTION AGAINST THE HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
10 - SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES, AND OTHER SAFETY HAZARDS
10 - 42. Excessive temperatures
11 - 44. Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
11 - 45. Pressure vessels and parts subject to pressure
11 - 46. Human errors
12 - 49. Interruption of the power supply
13 - SECTION EIGHT - ACCURACY OF THE OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
13 - 50. Accuracy of operating data
13 - 51. Protection against hazardous output
14 - SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS: ENVIRONMENT TESTS
14 - SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
14 - 56 Components and general assembly
15 - 57 MAIN PARTS, components and layout
17 - APPENDIX AA - RATIONALE
17 - AA19. Continuous leakage currentss and patient auxiliary currents
17 - AA20. Dielectric strength
18 - AA42. Excessive temperatures
18 - AA44. Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
18 - AA46. Human errors
18 - AA49. Interruption of the power supply
18 - AA50. Accuracy of operating data
18 - AA51. Protection against hazardous output
19 - AA47. Mains parts, components and layout
20 - APPENDIX BB - TESTING DURING MANUFACTURE AND/OR INSTALLATION
20 - APPENDIX ZZ - AMENDMENTS TO IEC 601.2.14 FOR APPLICATION IN AUSTRALIA

Specifies the requirements for the safety of electroconvulsive therapy equipment, including accessories. These requirements are not intended to be applied to equipment produced prior to the publication of this Standard. This Standard is to be read in conjunction with AS 3200.1.0-1990. It is identical with and reproduced from IEC 601-2-14:1988.

Committee
HE-003
DocumentType
Standard
ISBN
0 7262 7289 2
Pages
15
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This clause of the General Standard applies except as follows: 1.1 Scope Addition:This Particular Standard specifies the requirements for the safety of ELECTROCONVULSIVE THERAPY EQUIPMENT, as defined in Sub-clause 2.1.101, hereinafter referred to as EQUIPMENT.

Standards Relationship
IEC 60601-2-14:1989 Identical

First published as AS 3200.2.14-1992.