• AS 3200.2.20-1992

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Approval and test specification - Medical electrical equipment Particular requirements for safety - Baby incubators (transport)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  30-06-2017

    Language(s): 

    Published date:  01-01-1992

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 3200.2.20-1992 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY-BABY INCUBATORS (TRANSPORT)
    4 - PREFACE
    5 - CONTENTS
    7 - SECTION ONE-GENERAL
    7 - 1. Scope and object
    8 - 2. Terminology and definitions
    9 - 3. General requirements
    9 - 4. General requirements for tests
    10 - 5. Classification
    10 - 6. Identification, marking and documents
    12 - 7. Power input
    13 - SECTION TWO-ENVIRONMENTAL CONDITIONS
    13 - 10. Environmental conditions
    13 - SECTION THREE-PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
    13 - 20. Dielectric strength
    13 - SECTION FOUR-PROTECTION AGAINST MECHANICAL HAZARDS
    13 - 21. Mechanical strength
    14 - 22. Moving parts
    14 - 23. Surfaces, corners and edges
    15 - 24. Stability in NORMAL USE
    16 - SECTION FIVE-PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION
    16 - 36. Electromagnetic compatibility
    16 - SECTION SIX-PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
    17 - SECTION SEVEN-PROTECTION AGAINST EXCESSIVE TEMPERATURES, AND OTHER SAFETY HAZARDS
    17 - 42. Excessive temperatures
    17 - 43. * Fire prevention
    18 - 44. Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
    19 - 45. Pressure vessels and parts subject to PRESSURE
    19 - 46. Human errors
    20 - 49. Interruption of the power supply
    20 - SECTION EIGHT-ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
    20 - 50. Accuracy of operating data
    23 - 51. Protection against hazardous output
    23 - SECTION NINE-ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS
    23 - SECTION TEN-CONSTRUCTIONAL REQUIREMENTS
    23 - 54. General
    24 - 55. ENCLOSURES and covers
    24 - 56. Components and general assembly
    25 - SECTION ELEVEN-ADDITIONAL REQUIREMENTS
    25 - 101. Alarms
    27 - 102. Sound pressure level
    27 - 103. * Humidifying unit
    27 - 104. * Maximum air velocity in the enclosure
    27 - 105. * Concentration of carbon dioxide (CO2 )
    28 - 106. Provision of oxygen
    28 - 107. Electrical power supply
    32 - Annexes
    32 - Appendix L - References - Publications mentioned in this standard
    33 - Annex AA - General guidance and rationale
    38 - APPENDIX LL - REFERENCES-PUBLICATIONS MENTIONED IN THIS STANDARD
    38 - APPENDIX TT - TOLERANCES FOR APPLICATION IN AUSTRALIA
    39 - APPENDIX ZZ - AMENDMENTS TO IEC 601-2-20 FOR APPLICATION IN AUSTRALIA

    Abstract - (Show below) - (Hide below)

    Specifies requirements for transport incubators suitable for the safe conveyance of a baby outside a normal clinical baby-care environment. This Standard does not apply to transport incubators in which heating is provided by means of radiant heat sources. This Standard is to be read in conjunction with AS 3200.1.0-1990, and is technically equivalent to IEC 601-2-20:1990.

    Scope - (Show below) - (Hide below)

    Addition:This Particular Standard specifies safety requirements for TRANSPORT INCUBATORS, as defined in 2.1.101 of this standard.This standard does not apply to BABY INCUBATORS (see IEC 601-2-19).

    General Product Information - (Show below) - (Hide below)

    Committee HE-003
    Document Type Standard
    Publisher Standards Australia
    Status Withdrawn
    Supersedes

    History - (Show below) - (Hide below)

    Amendment 1 to AS 3200.2.20-1992 see DR 98481 First published as part of AS 3201.2-1971Ap.Revised and redesignated in part as AS 3200.2.20-1992. First published as part of AS 3201.2-1971Ap. Revised and redesignated in part as AS 3200.2.20-1992.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1259.1-1990 Acoustics - Sound level meters Non-integrating
    AS 3200.2.19-1992 Approval and test specification - Medical electrical equipment Particular requirements for safety - Baby incubators (nursing)
    AS/NZS 3200.1.0-1998 Medical electrical equipment General requirements for safety - Parent Standard
    AS 3200.1.0-1990 Approval and test specification - Medical electrical equipment General requirements for safety - Parent Standard

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 3200.2.19-1992 Approval and test specification - Medical electrical equipment Particular requirements for safety - Baby incubators (nursing)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective