• AS 3565.1-2004

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Meters for water supply Cold water meters

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  16-09-2023

    Language(s):  English

    Published date:  14-01-2004

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 3565.1-2004 METERS FOR WATER SUPPLY - COLD WATER METERS
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1 SCOPE AND GENERAL
    6 - 1.1 SCOPE
    6 - 1.2 REFERENCED DOCUMENTS
    7 - 1.3 DEFINITIONS
    7 - 1.3.1 Actual Volume (Va)
    7 - 1.3.2 Adjustment device
    7 - 1.3.3 Ancillary device
    8 - 1.3.4 Associated measuring instruments
    8 - 1.3.5 Calculator
    8 - 1.3.6 Combination meter
    8 - 1.3.7 Combined meter
    8 - 1.3.8 Complete meter
    8 - 1.3.9 Concentric meter
    8 - 1.3.10 Concentric meter manifold
    8 - 1.3.11 Correction device
    8 - 1.3.12 Disturbance
    8 - 1.3.13 Electronic device
    9 - 1.3.14 Error of indication
    9 - 1.3.15 First element of the register
    9 - 1.3.16 Flow sensor or volume sensor
    9 - 1.3.17 Flow rate (Q)
    9 - 1.3.18 Indicated volume (Vi )
    9 - 1.3.19 Influence quantity
    9 - 1.3.20 Influence factor
    9 - 1.3.21 In-line meter
    9 - 1.3.22 Limiting conditions (LCs)
    9 - 1.3.23 Minimum flow rate (Q1) (see Clause 1.6)
    9 - 1.3.24 Maximum permissible error (MPE)
    9 - 1.3.25 Measurement transducer
    10 - 1.3.26 Nominal diameter (DN)
    10 - 1.3.27 Overload flow rate (Q4) (see Clause 1.6)
    10 - 1.3.28 Permanent flow rate (Q3) (see Clause 1.6)
    10 - 1.3.29 Pressure loss (delta p)
    10 - 1.3.30 Primary indication
    10 - 1.3.31 Rated operating conditions (ROC)
    10 - 1.3.32 Register
    10 - 1.3.33 Relative error
    10 - 1.3.34 Reference conditions
    10 - 1.3.35 Sub-assembly
    10 - 1.3.36 Transitional flow rate (Q2 ) (see Clause 1.6)
    10 - 1.3.37 Verification scale interval
    10 - 1.3.38 Working pressure
    10 - 1.3.39 Working temperature
    11 - 1.4 MARKING
    11 - 1.4.1 Identification marks
    11 - 1.4.2 Verification marks
    11 - 1.5 PREFERRED UNITS
    12 - 1.6 PREFERRED FLOW RATES
    12 - 1.7 PREFERRED DIMENSIONS
    13 - SECTION 2 MATERIALS AND COMPONENTS
    13 - 2.1 MATERIALS
    13 - 2.1.1 General
    13 - 2.1.2 Copper alloys
    13 - 2.1.3 Contamination of water
    13 - 2.2 END CONNECTIONS
    13 - 2.2.1 Threaded end connections
    13 - 2.2.2 Flanged end connections
    14 - 2.3 REGISTER
    14 - 2.3.1 General
    14 - 2.3.2 Unit of measurement, symbol and placement
    14 - 2.3.3 Indicating range
    14 - 2.3.4 Colour coding for registers
    14 - 2.3.5 Types of register
    16 - 2.3.6 Supplementary devices
    17 - 2.3.7 Verification devices-First element of a register-Verification scale interval
    17 - 2.4 CALIBRATION ADJUSTMENT DEVICE
    17 - 2.5 PROTECTIVE DEVICES
    18 - 2.6 FROST PROTECTION
    18 - 2.7 STRAINERS
    19 - SECTION 3 PERFORMANCE REQUIREMENTS
    19 - 3.1 GENERAL
    19 - 3.2 OPERATING TEMPERATURE
    19 - 3.3 ULTRAVIOLET LIGHT EXPOSURE
    19 - 3.4 TORQUE RESISTANCE OF THREADED END CONNECTIONS
    19 - 3.5 WATERTIGHTNESS
    19 - 3.6 NON-REVERSING DEVICE
    19 - 3.7 REVERSE FLOW
    19 - 3.8 PRESSURE LOSS
    20 - 3.9 MAXIMUM ERROR OF MEASUREMENT
    20 - 3.10 ENDURANCE
    21 - SECTION 4 PERFORMANCE TESTS
    21 - 4.1 GENERAL
    21 - 4.2 PATTERN APPROVAL
    21 - 4.3 TYPE TESTS
    22 - APPENDIX A - MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS STANDARD
    22 - A1 SCOPE
    22 - A2 RELEVANCE
    22 - A3 PRODUCT CERTIFICATION
    22 - A3.1 Definitions
    23 - A3.2 Batch release test (BRT)
    23 - A3.3 Type testing (TT)
    23 - A4 TESTING
    23 - A4.1 General
    23 - A4.2 Type testing sampling
    23 - A4.3 Retesting
    23 - A4.4 Pattern approval
    23 - A4.5 Acceptability of tests
    26 - APPENDIX B - PURCHASING GUIDELINES
    26 - B1 GENERAL
    26 - B2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
    26 - B3 CERTIFICATES
    27 - APPENDIX C - METROLOGICAL REQUIREMENTS
    27 - C1 SCOPE
    27 - C2 METER DESIGNATION AND PERMANENT FLOW RATE (Q3)
    27 - C3 MEASURING RANGE
    27 - C4 RELATIONSHIP BETWEEN PERMANENT FLOW RATE (Q3 ) AND OVERLOAD FLOW RATE (Q4)
    28 - C5 RELATIONSHIP BETWEEN TRANSITIONAL FLOW RATE (Q2) AND MINIMUM FLOW RATE (Q1)
    28 - C6 REFERENCE FLOW RATE
    28 - C7 MAXIMUM PERMISSIBLE ERROR
    28 - C7.1 Sign of the error
    28 - C7.2 Relative error (ε)
    28 - C7.3 Temperature and pressure variations MPE requirements
    28 - C7.4 Water meters with separate calculator and measurement transducer
    28 - C7.5 Zero flow totalization
    29 - APPENDIX D - TECHNICAL DATA
    29 - D1 SCOPE
    29 - D2 TECHNICAL DATA
    31 - APPENDIX E - ULTRAVIOLET LIGHT EXPOSURE TEST
    31 - E1 SCOPE
    31 - E2 PRINCIPLE
    31 - E3 APPARATUS
    31 - E4 PROCEDURE
    32 - E5 REPORT
    33 - APPENDIX F - TORQUE RESISTANCE OF THREADED END CONNECTIONS TEST
    33 - F1 SCOPE
    33 - F2 PRINCIPLE
    33 - F3 APPARATUS
    33 - F4 PROCEDURE
    34 - F5 REPORT
    35 - APPENDIX G - WATERTIGHTNESS TEST
    35 - G1 SCOPE
    35 - G2 PRINCIPLE
    35 - G3 APPARATUS
    35 - G4 PROCEDURE
    36 - G5 REPORT
    37 - APPENDIX H - NON-REVERSING DEVICE LEAKAGE TEST
    37 - H1 SCOPE
    37 - H2 PRINCIPLE
    37 - H3 APPARATUS
    37 - H4 PROCEDURE
    37 - H5 CALCULATION
    38 - H6 REPORT
    39 - APPENDIX I - REVERSE FLOW TEST
    39 - I1 SCOPE
    39 - I2 PRINCIPLE
    39 - I3 APPARATUS
    39 - I4 PROCEDURE
    40 - I5 REPORT
    41 - APPENDIX J - PRESSURE LOSS TEST
    41 - J1 SCOPE
    41 - J2 PRINCIPLE
    41 - J3 APPARATUS
    42 - J4 PROCEDURE
    43 - J5 CALCULATIONS
    43 - J6 REPORT
    44 - APPENDIX K - ERROR OF MEASUREMENT TEST
    44 - K1 SCOPE
    44 - K2 PRINCIPLE
    44 - K3 APPARATUS
    44 - K3.2 Sampling
    45 - K3.3 Errors (of indication)
    45 - K4 PROCEDURE
    46 - K5 REPORT
    49 - APPENDIX L - ENDURANCE TEST
    49 - L1 SCOPE
    49 - L2 PRINCIPLE
    49 - L3 ENDURANCE CRITERIA
    49 - L4 APPARATUS
    50 - L5 PROCEDURE
    50 - L5.1 Meters with nominal flow rate (Q3) equal to or less than 16 kL/h
    51 - L5.2 Meters with nominal flow rate (Q3) greater than 16 kL/h
    51 - L6 CALCULATION
    51 - L7 REPORT
    53 - APPENDIX M - APPARATUS FOR TEST RIGS
    53 - M1 SCOPE
    53 - M2 CALIBRATED REFERENCE DEVICE
    53 - M2.1 General
    54 - M2.2 Uncertainties in the test methods
    54 - M3 DRINKING WATER SUPPLY
    54 - M4 TEMPERATURE INDICATOR
    54 - M5 TIMING DEVICE
    55 - M6 PRESSURE INDICATOR
    55 - M7 DIFFERENTIAL PRESSURE INDICATOR
    55 - M8 FLOW RATE INDICATOR
    55 - M9 PRESSURE TAPPINGS

    Abstract - (Show below) - (Hide below)

    This Standard specifies requirements for water meters for use in cold water systems to measure the volume of cold drinking water or Type A or B recycled water using certain types of meters.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements for water meters for use in cold water systems to measure the volume of cold drinking water or Type A or B recycled water using the following types of meters: (a) Volumetric, not exceeding 63 kL/h.(b) Multi-jet, not exceeding 63 kL/h.(c) Single-jet meters, not exceeding 63 kL/h. (d) Helical vane meters with permanent flow rates not exceeding 250 kL/h. The operating conditions of the meters being—(i) working temperature ranges of 0.3°C to 30°C; and(ii) operating pressures not exceeding 1400 kPa. This Standard is applicable to meters that are self-contained and capable of continuously determining, within the accuracy limits of the class, the volume of cold drinking water that has flowed through them, and that are continuously indicating the volume on a cumulative basis. Means for demonstrating compliance with this Standard is given in Appendix A NOTE: Purchasing guidelines are given in Appendix B.

    General Product Information - (Show below) - (Hide below)

    Committee WS-024
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS 3565-1988.Revised and redesignated AS 3565.1-1994.Second edition 1993.Third edition 2004. First published as AS 3565-1988. Revised and redesignated AS 3565.1-1994. Second edition 1993. Third edition 2004. First published as AS 3565-1988. Revised and redesignated AS 3565.1-1994. Second edition 1993. Third edition 2004.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 4020:2005 Testing of products for use in contact with drinking water
    AS 1349-1986 Bourdon tube pressure and vacuum gauges (Reconfirmed 2018)
    AS/NZS ISO 9002:1994 Quality systems - Model for quality assurance in production, installation and servicing
    AS/NZS 3500.1:2003 Plumbing and drainage Water services
    AS 4087-2004 Metallic flanges for waterworks purposes
    AS 2345-1992 Dezincification resistance of copper alloys
    AS 2345-2006 Dezincification resistance of copper alloys
    AS 1722.2-1992 Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017)
    AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
    AS/NZS 4020:2002 Testing of products for use in contact with drinking water
    AS 4087-1996 Metallic flanges for waterworks purposes
    AS 3558.5-1999 Methods of testing plastics and composite materials sanitary plumbing fixtures Determination of degradation by ultraviolet light (Reconfirmed 2016)

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 3565.5-2004 Meters for water supply - Water meters with two integral single check valves
    AS 5200.000-2006 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products (Reconfirmed 2018)
    AS 3565.4-2007 Meters for cold and heated drinking and non-drinking water supplies In-service compliance testing (Reconfirmed 2019)
    AS/NZS 2845.1:2010 Water supply - Backflow prevention devices Materials, design and performance requirements
    MP 52-2005 Manual of authorization procedures for plumbing and drainage products
    AS 3565.2-2004 Meters for water supply - Combination meters
    AS 5200.000-2005 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products
    ATS 4747.2-2008 Meters for non-urban water supply Specification for closed conduit meters fully charged
    AS/NZS 2845.1:1998 Water supply - Backflow prevention devices Materials, design and performance requirements
    ATS 4747.3-2008 Meters for non-urban water supply - Specifications for open channel meters
    AS 3565.3-2004 Meters for water supply - Water meters with integral dual check valves
    ATS 5200.030-2007 Technical Specification for plumbing and drainage products Solenoid valves
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective