• Shopping Cart
    There are no items in your cart

AS 3774 SUPP 1-1997

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Loads on bulk solids containers - Commentary (Supplement 1 to AS 3774-1996)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

03-11-2021

Language(s)

English

Published date

05-12-1997

€32.89
Excluding VAT

1 - AS 3774 Supp1-1997 LOADS ON BULK SOLIDS CONTAINERS-COMMENTARY (SUPPLEMENT 1 TO AS 3774-1996)
4 - PREFACE
5 - CONTENTS
6 - SECTION C4 LOAD CLASSIFICATION, LOAD COMBINATIONS, AND LOAD FACTORS
6 - C4.1 GENERAL
6 - C4.2 LOAD COMBINATIONS
6 - C4.3 LOAD FACTORS
7 - SECTI ON C6 DE TERMINATION OF NORMAL SERVICE LOADS (GROUP B)
7 - C6.1 RELEVANT PROPERTIES OF STORED BULK SOLID
7 - C6.1.1 General
7 - C6.1.2 Unit weight of bulk solid
7 - C6.1.3 Angle of wall friction
7 - C6.1.4 Effective angle of internal friction
7 - C6.1.5 Consistent material properties
8 - C6.2 INITIAL LOADS ON SYMMETRICALLY FILLED CONTAINER WALLS (LOAD TYPE B.2)
8 - C6.2.1 Initial normal pressures on vertical walls
10 - C6.2.2 Initial frictional forces on vertical walls
10 - C6.2.3 Initial forces on container closures
11 - C6.3 LOADS INDUCED BY FLOW DURING SYMMETRICAL DISCHARGES (LOAD TYPE B.3)
11 - C6.3.1 Method of determining symmetrical flow loadings
11 - C6.3.2 Normal pressures on the vertical walls
12 - C6.3.3 Friction on vertical walls
12 - C6.3.4 Vertical loads on container bottoms
12 - C6.3.5 Normal pressures on hoppers
13 - C6.3.6 Frictional tractions on hoppers
13 - C6.4 INITIAL LOADS ON ECCENTRICALLY FILLED CONTAINER WALLS (LOAD TYPE B.2)
13 - C6.4.1 Normal pressures on vertical walls
13 - C6.4.2 Frictional tractions on vertical walls
13 - C6.5 FLOW LOADS ON ECCENTRICALLY DISCHARGED CONTAINER WALLS (LOAD TYPE B. 3)
13 - C6.5.1 General
13 - C6.5.2 Normal pressures on vertical walls
14 - C6.6 LOADS ASSOCIATED WITH GATES AND FEEDERS
14 - C6.6.2 Increased gate and feeder loads due to large drop heights and rapid fill rates
14 - C6.6.3 Horizontal loads on containers due to unattached feeders
14 - C6.7 LIVE LOADS ON PLATFORMS AND ROOFS (LOAD TYPE B.5)
14 - C6.9 FORCES FROM LATERAL RESTRAINTS (LOAD TYPE B.7)
14 - C6.9.1 Loads in lateral restraints
14 - C6.9.2 Loads due to the container being used as a restraint
14 - C6.10 LOADS ON INTERNAL STRUCTURAL ELEMENTS WITHIN THE STORED SOLID (LOAD TYPE B.8)
14 - C6.10.1 General
14 - C6.10.2 Vertical pressures on internal structural elements
14 - C6.10.3 Horizontal pressures on internal structural elements
14 - C6.10.4 Frictional tractions on internal structural elements
14 - C6.10.5 Vertical forces in internal structural elements
15 - REFERENCES
17 - SECTION C7 DETERMINATION OF ENVIRONMENTAL LOADS (GROUP C)
17 - C7.1 WIND LOADS (LOAD TYPE C.1)
17 - C7.1.2 Negative internal air pressure
17 - C7.2 LOADS DUE TO DIFFERENTIAL SETTLEMENT OF FOUNDATIONS (LOAD TYPE C.2)
17 - C7.2.1 Assessment of differential settlements
17 - C7.2.2 Differential settlement under column-supported containers
17 - C7.2.3 Differential settlement under ground-supported containers
17 - C7.3 LOADS DUE TO DIFFERENTIAL TEMPERATURE (LOAD TYPE C.3)
17 - C7.3.1 Assessment of differential temperature
17 - C7.3.2 Temperature decrease in container walls
18 - C7.3.3 Temperature differentials in supporting columns
18 - C7.3.4 Storage of hot bulk solids
18 - C7.4 SEISMIC LOADS (LOAD TYPE C.4)
18 - C7.5 LOADS DUE TO SWELLING OF STORED BULK SOLIDS (LOAD TYPE C.5)
18 - REFERENCES
19 - APPENDIX CC - TESTING TO DETERMINE PROPERTIES OF BULK SOLIDS
20 - APPENDIX CD - PRESSURE CAUSED BY INTERNAL EXPLOSION

Provides background materials from which requirements are derived in AS3774.

Committee
BD/65
DocumentType
Supplement (Main)
ISBN
0 7337 1637 7
Pages
15
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

Originated as AS 3774 Supplement 1-1990.
Second edition 1997.

HB 867-2007 Supplementary information for design of farm structures
AS 3880:2017 Flow properties of coal

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.