AS 4032.1-2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Water supply - Valves for the control of hot water supply temperatures Thermostatic mixing valves - Materials design and performance requirements
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-2002
Specifies requirements for the design, construction, testing and performance of thermostatic mixing valves of nominal sizes not larger than DN 32, for use with hot water at a supply temperature not exceeding 90 degrees Celsius, and hot and cold water with continuous working pressures not exceeding 1400 kPa.
Committee |
WS-026
|
DocumentType |
Standard
|
ISBN |
0 7337 4192 4
|
Pages |
34
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for the design, construction, testing and performanceof thermostatic mixing valves of nominal sizes not larger than DN 32, for use with hotwater at a supply temperature not exceeding 90C, and hot and cold water with continuousworking pressures not exceeding 1400 kPa.The principal element of the testing procedures is that the thermostatic mixing valve undertest does not permit the discharge of water from the outlet with a temperature more than2C in excess of the nominated discharge temperature. Discharges of water with atemperature in excess of 2C, which comply with the cumulative time/temperature factorsgiven in Table 4.1, are acceptable.NOTE: Manufacturers may negotiate with the certifying body on hot water supply temperaturesup to 99C, or hot and cold water continuous working pressures greater than 1400 kPa or both, if considered desirable, to assess temperature stability of the mixed water (see Clauses 1.7 and 5.2).
First published as AS 4032-1992.
Second edition 1995.
Third eidition 1998.
Revised and redesignated as AS 4032.1-2002.
AS 4032.1-2005 | Water supply - Valves for the control of heated water supply temperatures Thermostatic mixing valves - Materials design and performance requirements |
AS/NZS 3500.4:2003 | Plumbing and drainage Heated water services |
MP 52-2005 | Manual of authorization procedures for plumbing and drainage products |
AS 4032.3-2004 | Water supply - Valves for the control of heated water supply temperatures Requirements for field-testing, maintenance or replacement of thermostatic mixing valves, tempering valves and end-of-line temperature control devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.