• AS 4086.1-1993

    Current The latest, up-to-date edition.

    Secondary batteries for use with stand-alone power systems General requirements (Reconfirmed 2022)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  15-03-1993

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 4086.1:1993 SECONDARY BATTERIES FOR USE WITH STAND-ALONE POWER SYSTEMS - GENERAL REQUIREMENTS
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1 - SCOPE AND GENERAL
    6 - 1.1 SCOPE
    6 - 1.2 REFERENCED DOCUMENTS
    6 - 1.3 DEFINITIONS
    7 - 1.4 INFORMATION TO BE PROVIDED BY THE MANUFACTURER
    7 - 1.5 MARKING
    7 - 1.5.1 Cell and monobloc marking
    7 - 1.5.2 Polarity marking
    7 - 1.5.2.1 General
    7 - 1.5.2.2 Symbols
    8 - 1.5.2.3 Coloured discs
    9 - SECTION 2 - FUNCTIONAL CHARACTERISTICS AND REQUIREMENTS
    9 - 2.1 CAPACITY
    9 - 2.1.1 General
    9 - 2.1.2 120 hour rate
    9 - 2.1.3 10 hour rate
    9 - 2.2 CYCLE LIFE
    9 - 2.2.1 General
    9 - 2.2.2 Measurement
    9 - 2.3 RESISTANCE TO OVERCHARGE
    9 - 2.3.1 General
    9 - 2.3.2 Measurement
    9 - 2.4 CHARGE RETENTION
    9 - 2.4.1 General
    9 - 2.4.2 Measurement
    9 - 2.5 CHARGE-DISCHARGE EFFICIENCY
    9 - 2.5.1 General
    9 - 2.5.2 Requirement
    9 - 2.6 CAPACITY RECOVERY FOLLOWING OVER- DISCHARGE
    9 - 2.6.1 General
    9 - 2.6.2 Requirement
    10 - 2.7 MECHANICAL ENDURANCE
    10 - 2.8 INTERNAL RESISTANCE
    10 - 2.9 ELECTROLYTE LEVEL INDICATION
    11 - SECTION 3 - TEST CONDITIONS
    11 - 3.1 ACCURACY OF MEASURING INSTRUMENTS
    11 - 3.1.1 Voltmeters
    11 - 3.1.2 Ammeters
    11 - 3.1.3 Thermometers
    11 - 3.2 PREPARATION OF TEST BATTERIES
    11 - 3.3 TEST SEQUENCE
    12 - APPENDIX A - CAPACITY TEST METHOD (120 HOUR DISCHARGE RATE)
    12 - A1 APPARATUS
    12 - A2 PROCEDURE
    12 - A3 REPORTING OF RESULTS
    13 - APPENDIX B - CAPACITY TEST METHOD (10 HOUR DISCHARGE RATE)
    13 - B1 APPARATUS
    13 - B2 PROCEDURE
    13 - B3 REPORTING OF RESULTS
    14 - APPENDIX C - CYCLE LIFE TEST METHOD
    14 - C1 APPARATUS
    14 - C2 PROCEDURE
    14 - C3 REPORTING OF RESULTS
    15 - APPENDIX D - OVERCHARGE RESISTANCE TEST METHOD
    15 - D1 APPARATUS
    15 - D2 PROCEDURE
    15 - D3 CALCULATION
    15 - D4 REPORTING OF RESULTS
    16 - APPENDIX E - CHARGE RETENTION TEST METHOD
    16 - E1 APPARATUS
    16 - E2 PROCEDURE
    16 - E3 CALCULATION
    16 - E4 REPORTING OF RESULTS
    17 - APPENDIX F - CHARGE-DISCHARGE EFFICIENCY TEST METHOD
    17 - F1 APPARATUS
    17 - F2 PROCEDURE
    17 - F2.1 Test battery
    17 - F2.2 Capacity at the 10 h rate
    17 - F2.3 Capacity at the 120 h rate
    17 - F2.4 Efficiency at 90% state of charge
    18 - F2.5 Efficiency at 80% state of charge
    18 - F3 CALCULATION
    18 - F4 REPORTING OF RESULTS
    19 - APPENDIX G - CAPACITY RECOVERY TEST METHOD
    19 - G1 APPARATUS
    19 - G2 PROCEDURE
    19 - G3 CALCULATION
    19 - G3 REPORTING OF RESULTS
    20 - APPENDIX H - MECHANICAL ENDURANCE TEST METHODS
    20 - H1 THERMAL CYCLING TEST
    20 - H1.1 Procedure
    20 - H2 BUMP TEST
    20 - H2.1 Procedure
    20 - H3 DROP TEST
    20 - H3.1 Procedure
    20 - H4 VIBRATION TEST
    20 - H4.1 Procedure
    20 - H3 REPORTING OF RESULTS
    21 - APPENDIX I - INTERNAL RESISTANCE TEST METHOD
    21 - I1 PROCEDURE
    21 - I2 CALCULATION
    21 - I3 REPORTING OF RESULTS

    Abstract - (Show below) - (Hide below)

    Specifies requirements for secondary batteries for use with power systems not connected to the distribution system of an electricity supply authority. Covers both performance and safety requirements and provides test methods.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements for secondary batteries for use with stand-alone power systems.Stand-alone power systems are those that are not connected to the power distribution system of an electricity supply authority. Stand-alone systems are supplied with power from one or a combination of the following sources: a photovoltaic array, a wind generator, a water generator or a diesel generator. This Standard specifies requirements for all types of batteries including lead-acid and nickel-cadmium and covers both vented and sealed cells. The Standard includes tests designed to verify the capacity, efficiency and life of batteries (see Appendices A to I).

    General Product Information - (Show below) - (Hide below)

    Committee EL/5
    Document Type Standard
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS 4086.1-1993.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1099.2.31-1990 Basic environmental testing procedures for electrotechnology Tests - Test Ec - Drop and topple, primarily for equipment
    AS 1099.2.6-1988 Basic environmental testing procedures for electrotechnology Tests - Test Fc - Vibration (sinusoidal)
    AS 2700-1996 Colour Standards for general purposes - Swatches
    AS 1104-1978 Informative symbols for use on electrical and electronic equipment
    AS 1042-1973 Direct-acting indicating electrical measuring instruments and their accessories
    AS 1099.2.29-1990 Basic environmental testing procedures for electrotechnology Tests - Test Eb - Bump and guidance

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 4029.1-1994 Stationary batteries - Lead-acid Vented type (based on and including the full text of IEC 896-1)
    AS 5156-2010 Electronic speed limit signs
    AS/NZS 2201.1:2007 Intruder alarm systems Client’s premises - Design, installation, commissioning and maintenance
    AS/NZS 4509.2:2010 Stand-alone power systems System design (Reconfirmed 2017)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective