• AS 4118.1.1-1996

    Current The latest, up-to-date edition.

    Fire sprinkler systems Components - Sprinklers and sprayers (Reconfirmed 2013)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  05-06-1996

    Publisher:  Standards Australia

    Add To Cart

    Description - (Show below) - (Hide below)

    This Standard has been reconfirmed. To view or download the Reconfirmation Notice please click here.

    Table of Contents - (Show below) - (Hide below)

    1 - AS 4118.1.1-1996 FIRE SPRINKLER SYSTEMS - COMPONENTS-SPRINKLERS AND SPRAYERS
    4 - PREFACE
    5 - CONTENTS
    7 - SECTION 1 SCOPE AND GENERAL
    7 - 1.1 SCOPE
    7 - 1.2 NEW DESIGNS AND INNOVATIONS
    7 - 1.3 REFERENCED DOCUMENTS
    8 - 1.4 DEFINITIONS
    8 - 1.4.1 Conductivity factor (C)
    8 - 1.4.2 Listed
    8 - 1.4.3 Response time index (RTI)
    8 - 1.4.4 Sprinkler
    8 - 1.4.5 Standard orientation
    8 - 1.4.6 Worst-case orientation
    8 - 1.5 DEEMED TO SATISFY
    9 - 1.6 INTERPRETATION OF SPECIFIED LIMITING VALUES
    10 - SECTION 2 TYPES OF SPRINKLERS
    10 - 2.1 TYPE OF SPRINKLER ACCORDING TO TYPE OF HEAT RESPONSIVE ELEMENT
    10 - 2.1.1 Metallic element sprinkler
    10 - 2.1.2 Frangible glass bulb sprinkler
    10 - 2.2 TYPE OF SPRINKLER ACCORDINGTO WATER DISTRIBUTION
    10 - 2.2.1 Conventional sprinkler
    10 - 2.2.2 Spray-sprinkler
    10 - 2.2.3 Flat spray-sprinkler
    10 - 2.2.4 Sidewall sprinkler
    10 - 2.2.5 Residential sprinkler
    14 - 2.3 TYPE OF SPRINKLER ACCORDINGTO MOUNTING POSITION
    14 - 2.3.1 Upright sprinkler
    14 - 2.3.2 Pendent sprinkler
    14 - 2.3.3 Horizontal sprinkler
    14 - 2.4 SPECIAL TYPES OF SPRINKLER
    14 - 2.4.1 Dry sprinkler
    14 - 2.4.2 Flush sprinkler
    14 - 2.4.3 Recessed sprinkler
    14 - 2.4.4 Concealed sprinkler
    14 - 2.4.5 On- off sprinkler
    14 - 2.4.6 Fast- response sprinkler
    14 - 2.4.7 Residential sprinkler
    14 - 2.4.8 Extended coverage sprinkler
    14 - 2.4.9 Large drop sprinkler
    14 - 2.4.10 Early suppression fast- response
    14 - 2.4.11 Large orifice and extra large orifice
    14 - 2.4.12 Quick response sprinkler
    15 - SECTION 3 REQUIREMENTS
    15 - 3.1 DIMENSIONS
    15 - 3.2 UPGRADING OF SPRINKLER INSTALLATIONS
    15 - 3.3 NOMINAL RELEASE TEMPERATURES
    15 - 3.4 OPERATING TEMPERATURES
    15 - 3.4.1 Metallic element sprinklers
    16 - 3.4.2 Frangible glass bulb sprinklers
    16 - 3.5 WATER FLOW AND DISTRIBUTION
    16 - 3.5.1 Flow constant
    16 - 3.5.2 Water distribution
    16 - 3.6 FUNCTION
    16 - 3.6.1 Release temperatures
    17 - 3.6.2 Deflector strength
    17 - 3.7 STRENGTH OF SPRINKLER BODY
    17 - 3.8 STRENGTH OF RELEASE ELEMENT
    17 - 3.8.1 Frangible glass bulbs
    17 - 3.8.2 Metallic heat- responsive elements
    17 - 3.9 LEAK RESISTANCE
    17 - 3.10 HEAT EXPOSURE
    17 - 3.10.1 Frangible glass bulb sprinklers
    17 - 3.10.2 Uncoated sprinklers
    17 - 3.10.3 Coated sprinklers
    17 - 3.11 THERMAL SHOCK
    17 - 3.12 CORROSION
    17 - 3.12.1 Stress corrosion
    17 - 3.12.2 Sulfur dioxide corrosion
    17 - 3.12.3 Salt spray corrosion
    17 - 3.12.4 Moist air exposure
    18 - 3.13 INTEGRITY OF SPRINKLER COATING
    18 - 3.13.1 Evaporation of wax and bitumen
    18 - 3.13.2 Resistance to low temperatures
    18 - 3.13.3 Resistance to high temperatures
    18 - 3.14 WATER HAMMER
    18 - 3.15 DYNAMIC HEATING
    18 - 3.15.1 RTI determination
    18 - 3.15.2 Post-exposure RTI
    18 - 3.16 RESISTANCE TO HEAT
    18 - 3.17 RESISTANCE TO VIBRATION
    18 - 3.18 RESISTANCE TO IMPACT
    18 - 3.19 CRIB FIRE PERFORMANCE
    19 - 3.20 LATERAL DISCHARGE
    19 - 3.21 30 DAY LEAKAGE RESISTANCE
    19 - 3.22 VACUUM RESISTANCE
    20 - SECTION 4 TEST METHODS
    20 - 4.1 GENERAL
    20 - 4.2 EXAMINATION
    20 - 4.2.1 Preliminary examination
    20 - 4.2.2 Visual examination
    20 - 4.3 DETERMINATION OF SERVICE LOAD
    20 - 4.3.1 Measurements at service load
    20 - 4.3.2 Measurements at twice the service load
    22 - 4.4 LEAK-RESISTANCE TEST
    22 - 4.5 FUNCTIONAL TEST
    22 - 4.5.1 Sprinklers less than 78°C
    22 - 4.5.2 Sprinklers more than 78°C
    22 - 4.5.3 Following pressures
    22 - 4.5.4 Lodgement and test quantity escalation
    22 - 4.5.5 Lodgement
    22 - 4.5.6 Deflector strength
    22 - 4.6 TESTING THE CHARACTERISTICS OF THE HEAT RESPONSIVE ELEMENT
    22 - 4.6.1 Test of static operation behaviour
    23 - 4.6.2 Dynamic heating test
    28 - 4.7 HEAT EXPOSURE TEST
    28 - 4.7.1 Frangible glass bulb sprinklers
    28 - 4.7.2 Uncoated sprinklers
    28 - 4.7.3 Coated sprinklers
    28 - 4.8 THERMAL SHOCKTEST FOR GLASS BULB SPRINKLERS
    29 - 4.9 STRENGTH TEST FOR RELEASE ELEMENTS
    29 - 4.9.1 Frangible glass bulbs
    29 - 4.9.2 Fusible metallic elements
    29 - 4.10 WATER FLOW TEST
    29 - 4.11 WATER DISTRIBUTION TEST
    29 - 4.11.1 Conventional, spray, flat spray and dry sprinklers
    30 - 4.11.2 Sidewall sprinklers
    30 - 4.11.3 Water distribution above and below the deflector
    38 - 4.12 CORROSION TESTS
    38 - 4.12.1 Stress corrosion test with aqueous ammonia solution
    38 - 4.12.2 Sulfur dioxide corrosion test
    39 - 4.12.3 Salt spray corrosion test
    39 - 4.12.4 Sprinklers for moist air exposure
    39 - 4.13 TESTS FOR SPRINKLER COATINGS
    39 - 4.13.1 Evaporation test
    39 - 4.13.2 Low-temperature test
    40 - 4.14 HEAT-RESISTANCE TEST
    40 - 4.15 WATER-HAMMER TEST
    40 - 4.16 VIBRATION TEST
    40 - 4.16.1 Sinusoidal vibration
    40 - 4.16.2 Resonance points
    40 - 4.16.3 Leakage test
    40 - 4.17 IMPACT TEST
    42 - 4.18 CRIB FIRE TEST
    42 - 4.18.1 Apparatus
    44 - 4.18.2 Sprinkler installation
    46 - 4.18.3 Test room
    46 - 4.18.4 Procedure
    46 - 4.18.5 Performance criteria
    46 - 4.19 30 DAY LEAKAGE TEST
    47 - 4.20 VACUUM TEST
    48 - SECTION 5 MARKING
    49 - APPENDIX A - BIBLIOGRAPHY
    50 - APPENDIX B - NOTES ON THE STRENGTH TEST FOR RELEASE ELEMENTS

    Abstract - (Show below) - (Hide below)

    Specifies the performance and testing of metallic element and frangible glass bulb sprinklers and sprayers.

    Scope - (Show below) - (Hide below)

    This Standard specifies the performance and testing of metallic element and frangible glass bulb sprinklers and sprayers, as listed in Table 1.1.NOTE: Sprinklers and sprayers will be referred to throughout this text as sprinklers.Whilst this Standard recognizes that there are sprinklers other than those listed in Table 1.1, the acceptance of these sprinklers is dependent on their documented approval and listing by a recognized authority. Full testing procedures for sprinklers not listed in Table 1.1 are not necessarily included in this Standard.

    General Product Information - (Show below) - (Hide below)

    Committee FP/4
    Document Type Standard
    Product Note Reconfirmed 10-07-2013See also AS 2118-1982
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as part of AS CA16-1939 (endorsement of Seventh Edition of FOC Rules).Second edition 1948 (endorsement of Eighth Edition of FOC Rules).Third edition 1962 (endorsement of Ninth Edition of FOC Rules).Fourth edition 1971 (based on Twenty ninth Edition of FOC Rules).Revised and redesignated in part as AS 2118-1978.Second edition 1982.Revised and redesignated in part as AS 4118.1.1-1996.Reconfirmed 2013. Originated as part of AS CA16-1939 (endorsement of Seventh Edition of FOC Rules). Previous edition AS 2118-1982. Revised and redesignated in part as AS 4118.1.1-1996.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 4041-1998 Pressure piping
    AS 4041-2006 Pressure piping (Reconfirmed 2016)
    AS 2118.1-2006 Automatic fire sprinkler systems General systems
    AS 2706-1984 Numerical values - Rounding and interpretation of limiting values
    AS 2118.1-1995 Automatic fire sprinkler systems - Standard
    AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
    AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
    AS 2706-2003 Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018)

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 2118.3-2010 Automatic fire sprinkler systems Deluge systems
    AS 2118.1:2017 Automatic fire sprinkler systems General systems
    AS 2118.3-1997 Automatic fire sprinkler systems - Deluge
    AS/NZS 3500.1.2:1998 National plumbing and drainage Water supply - Acceptable solutions
    AS 2118.2-2010 Automatic fire sprinkler systems Drencher systems
    HB 147-2000 Sprinklers Simplified
    AS 4041-2006 Pressure piping (Reconfirmed 2016)
    AS 2118.2-1995 Automatic fire sprinkler systems - Wall wetting sprinklers (Drenchers)
    AS 2118.8-1997 Automatic fire sprinkler systems Minor modifications (Reconfirmed 2013)
    AS 2118.6-2012 Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings
    AS 2118.1-1995 Automatic fire sprinkler systems - Standard
    AS 2118.1-2006 Automatic fire sprinkler systems General systems
    AS/NZS 3500.1:2003 Plumbing and drainage Water services
    AS 2118.5-2008 Automatic fire sprinkler systems Home fire sprinkler systems (Reconfirmed 2020)
    ATS 5200.486-2008 Technical Specification for plumbing and drainage products Sprinklers for home applications
    AS 5414-2012 Bushfire water spray systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective