• AS 4747.2-2013

    Current The latest, up-to-date edition.

    Meters for non-urban water supply Technical requirements for closed conduit meters fully charged

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  21-02-2013

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Sets out requirements for water meters for use in non-urban applications. It primarily covers metering for irrigation water; however, it is intended that it be used for non-urban water applications other than applications covered by AS3565.1.

    Scope - (Show below) - (Hide below)

    This Standard sets out requirements for water meters for use in non-urban applications. It primarily covers metering for irrigation water; however, it is intended that it be used for non-urban water applications other than applications covered by AS 3565.1.Two types of meters are covered in this Standard, as follows:(a)A ‘self-contained unit’—a meter that defines its own geometry, is able to be pattern-approved as a complete water meter, calibrated upon assembly and supplied by a single supplier.(b)A ‘modular metering system’—a device or group of instruments (which may be supplied as a pattern-approved metering system,) that does not define the installation geometry and requires configuration after installation.NOTES: 1The requirements for these types of meters to demonstrate compliance with this Standard, and hence with the National Framework are described in Section 4 and illustrated in Figure 4.1.2Purchasing guidelines are given in Appendix A.This Standard applies to meters that are—(i)self-contained or modular and capable of continuously determining, within the accuracy limits, the volume of water that has flowed through them; and(ii)continuously updating the volume on a cumulative basis.NOTE: In this Standard a meter installation is considered to include—(a)the meter, its indicating device and all ancillary equipment; and(b)the upstream and downstream pipe or emplacement that may have a material effect on the meter unit.This Standard applies to meters that operate under the following conditions:(A)Closed conduit under full flow.(B)Pressure ranges minimum 0.03 MPa to a value specified by the manufacturer. As a minimum, insertion or clamp-on meters will need to have the same working pressure range as the pipes they are designed to operate in.(C)Working water temperature range of 0.1°C to 30°C. The maximum admissible temperature is 50°C, which is the limiting condition for the meter.(D)Ambient air temperature range of ?5°C to 55°C.(E)Ambient humidity range of 0% to 100% except for remote indicating devices where the range is 0% to 93%.

    General Product Information - (Show below) - (Hide below)

    Committee CE-024
    Document Type Standard
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as ATS 4747.2—2008.Revised and redesignated as AS 4747.2—2013. First published as ATS 4747.2-2008. Revised and redesignated as AS 4747.2-2013.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1722.2-1992 Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017)
    AS 4747.5-2013 Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged
    AS 1565-1996 Copper and copper alloys - Ingots and castings (Reconfirmed 2020)
    ATS 4747.1-2008 Meters for non-urban water supply Glossary of terms
    AS 2345-2006 Dezincification resistance of copper alloys
    AS 4747.6-2013 Meters for non-urban water supply Installation and commissioning of open channel meters
    AS 3778.1-2009 Measurement of water flow in open channels Hydrometric determinations - Vocabulary and symbols
    AS 4747.8-2013 Meters for non-urban water supply In-service compliance for non-urban water meters
    AS 4747.3-2013 Meters for non-urban water supply Technical requirements for open channel meters
    AS 4747.1-2013 Meters for non-urban water supply Glossary of terms
    AS 2129-2000 Flanges for pipes, valves and fittings (Reconfirmed 2016)
    AS/NZS 1567:1997 Copper and copper alloys - Wrought rods, bars and sections (Reconfirmed 2021)
    AS 4087:2011 Metallic flanges for waterworks purposes
    AS 2738-2000 Copper and copper alloys - Compositions and designations of refinery products, wrought products, ingots and castings (Reconfirmed 2018)
    AS 3558.5-1999 Methods of testing plastics and composite materials sanitary plumbing fixtures Determination of degradation by ultraviolet light (Reconfirmed 2016)

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 4747.6-2013 Meters for non-urban water supply Installation and commissioning of open channel meters
    AS 4747.1-2013 Meters for non-urban water supply Glossary of terms
    AS 4747.8-2013 Meters for non-urban water supply In-service compliance for non-urban water meters
    AS 4747.3-2013 Meters for non-urban water supply Technical requirements for open channel meters
    AS 4747.5-2013 Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective