• AS 4777.3-2002

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Grid connection of energy systems via inverters - Grid protection requirements

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  01-01-2002

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 4777.3-2002 GRID CONNECTION OF ENERGY SYSTEMS VIA INVERTERS - GRID PROTECTION REQUIREMENTS
    4 - PREFACE
    5 - CONTENTS
    6 - 1 SCOPE
    6 - 2 APPLICATION
    6 - 3 NORMATIVE REFERENCES
    7 - 4 DEFINITIONS
    7 - 4.1 Active anti-islanding protection
    7 - 4.2 Electricity distribution network
    7 - 4.3 Grid
    7 - 4.4 Inverter
    7 - 4.5 Inverter energy system
    7 - 4.6 Islanding
    7 - 4.7 Nominal grid voltage
    7 - 4.8 Passive anti-islanding protection
    7 - 4.9 Electro-mechanical switch
    8 - 4.10 Uninterruptible power supply (UPS) system
    8 - 5 GENERAL AND SAFETY REQUIREMENTS
    8 - 5.1 Electrical safety
    8 - 5.2 Connection to low-voltage distribution network
    8 - 5.3 EMC
    8 - 5.4 Voltage flicker
    8 - 5.5 Impulse protection
    8 - 5.6 Data logging and communications devices
    8 - 6 GRID PROTECTION REQUIREMENTS
    8 - 6.1 General
    9 - 6.2 Disconnection device
    9 - 6.3 Voltage and frequency limits (passive anti-islanding protection)
    9 - 6.4 Limits for sustained operation
    9 - 6.5 Active anti-islanding protection
    10 - 6.6 Reconnection procedure
    10 - 6.7 Security of protection settings
    10 - 6.8 Compliance with grid protection requirements
    11 - APPENDIX A - LIMITS FOR SUSTAINED OPERATION
    12 - APPENDIX B - GRID PROTECTION DEVICE TESTS
    12 - B1 GENERAL
    12 - B2 UNDER- AND OVER-VOLTAGE TRIP SETTINGS AND RECONNECTION TEST
    12 - B2.1 Tests
    13 - B2.2 Criteria for acceptance
    13 - B3 UNDER- AND OVER-FREQUENCY TRIP SETTINGS AND RECONNECTION TEST
    13 - B3.1 Tests
    14 - B3.2 Criteria for acceptance
    14 - B4 GRID TRIP TEST
    14 - B4.1 General
    16 - B4.2 Grid trip test under load condition (a)
    16 - B4.3 Grid trip test under load condition (b)
    17 - B4.4 Grid trip test under load condition (c)

    Abstract - (Show below) - (Hide below)

    Specifies grid protection requirements for inverter energy systems with ratings up to 10 kVA for single-phase units, or 30 kVA for three-phase units, and intended for connection to the low-voltage electricity distribution network (grid).

    Scope - (Show below) - (Hide below)

    This Standard specifies the requirements for grid protection devices intended to be used in inverter energy systems, with ratings up to 10 kVA for single-phase units, or up to 30 kVA for three-phase units, and for the injection of electric power through an electrical installation to the electricity distribution network.NOTES: 1 Although this Standard does not apply to larger systems, similar principles can be used for the grid protection of such systems.2 These devices do not replace devices used for protection and/or isolation as required in AS/NZS 3000.

    General Product Information - (Show below) - (Hide below)

    Committee EL-042
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS 4777.3-2002.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS/NZS 61000.3.3:1998 Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16 A
    AS 60038-2000 Standard voltages
    AS/NZS 60950:2000 Safety of information technology equipment (IEC 60950:1999, MOD)
    AS/NZS 61000.3.5:1998 Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 16 A
    AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 4777.2-2002 Grid connection of energy systems via inverters - Inverter requirements
    AS 4777.1-2002 Grid connection of energy systems via inverters - Installation requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective