• AS 7240.10-2007

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Fire detection and alarm systems Point-type flame detectors

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  02-03-2023

    Language(s):  English

    Published date:  18-04-2007

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 7240.10-2007 Fire detection and alarm systems Part 10: Point-type flame detectors
    4 - PREFACE
    6 - CONTENTS
    7 - INTRODUCTION
    9 - 1 Scope
    9 - 2 Normative references
    10 - 3 Terms and definitions
    11 - 4 General requirements
    11 - 4.1 Compliance
    11 - 4.2 Classification
    11 - 4.3 Individual alarm indication
    11 - 4.4 Connection of ancillary devices
    11 - 4.5 Monitoring of detachable detectors
    11 - 4.6 Manufacturer's adjustments
    12 - 4.7 On- site sensitivity adjustment
    12 - 4.8 Marking
    13 - 4.9 Data
    13 - 4.10 Requirements for software- controlled detectors
    13 - 4.10.1 General
    13 - 4.10.2 Software documentation
    14 - 4.10.3 Software design
    14 - 4.10.4 Storage of programs and data
    14 - 5 Tests
    14 - 5.1 General
    14 - 5.1.1 Atmospheric conditions for tests
    15 - 5.1.2 Operating conditions for tests
    15 - 5.1.3 Mounting arrangements
    15 - 5.1.4 Tolerances
    15 - 5.1.5 Determination of response point
    16 - 5.1.6 Test procedure
    16 - 5.1.7 Reduced functional tests
    16 - 5.1.8 Provision for tests
    17 - 5.1.9 Test schedule
    18 - 5.1.10 Test report
    18 - 5.2 Reproducibility
    18 - 5.2.1 Object of test
    18 - 5.2.2 Test procedure
    19 - 5.2.3 Requirements
    19 - 5.2.4 Object of test
    19 - 5.3 Repeatability
    19 - 5.3.1 Object of test
    19 - 5.3.2 Test procedure
    19 - 5.3.3 Requirements
    19 - 5.4 Directional dependence
    19 - 5.4.1 Object of test
    19 - 5.4.2 Test procedure
    20 - 5.4.3 Requirements
    20 - 5.5 Fire sensitivity
    20 - 5.5.1 Object of test
    21 - 5.5.2 Test procedure
    22 - 5.5.3 Classification
    23 - 5.5.4 Requirements
    23 - 5.6 Dazzling ( operational)
    23 - 5.6.1 Object of test
    24 - 5.6.2 Test procedure and apparatus
    24 - 5.6.3 Requirements
    24 - 5.7 Dry heat ( operational)
    24 - 5.7.1 Object of test
    25 - 5.7.2 Test procedure and apparatus
    25 - 5.7.3 Requirements
    25 - 5.8 Cold ( operational)
    25 - 5.8.1 Object of test
    25 - 5.8.2 Test procedure
    26 - 5.8.3 Requirements
    26 - 5.9 Damp heat, cyclic ( operational)
    26 - 5.9.1 Object of test
    26 - 5.9.2 Test procedure
    27 - 5.9.3 Requirements
    27 - 5.10 Damp heat, steady state ( endurance)
    27 - 5.10.1 Object of test
    27 - 5.10.2 Test procedure
    28 - 5.10.3 Requirements
    28 - 5.11 Sulfur dioxide ( SO2) corrosion ( endurance)
    28 - 5.11.1 Object of test
    28 - 5.11.2 Test procedure
    28 - 5.11.3 Requirements
    29 - 5.12 Shock ( operational)
    29 - 5.12.1 Object of test
    29 - 5.12.2 Test procedure and apparatus
    29 - 5.12.3 Requirements
    29 - 5.13 Impact ( operational)
    29 - 5.13.1 Object of test
    30 - 5.13.2 Test procedure
    30 - 5.13.3 Requirements
    30 - 5.14 Vibration, sinusoidal ( operational)
    30 - 5.14.1 Object of test
    30 - 5.14.2 Test procedure
    31 - 5.14.3 Requirements
    31 - 5.15 Vibration, sinusoidal ( endurance)
    31 - 5.15.1 Object of test
    32 - 5.15.2 Test procedure
    32 - 5.15.3 Requirements
    32 - 5.16 Variation of supply parameters ( operational)
    32 - 5.16.1 Object of test
    32 - 5.16.2 Test procedure
    33 - 5.16.3 Requirements
    33 - 5.17 Electromagnetic compatibility ( EMC) immunity tests ( operational)
    33 - 5.17.1
    33 - 5.17.2
    33 - 6 Test report
    34 - Annex A (normative) Marine test requirements
    51 - Annex B (normative) Apparatus for response point determination
    54 - Annex C (normative) Liquid (heptane) fire (TF5)
    55 - Annex D (normative) Liquid (methylated spirit) fire (TF6)
    56 - Annex E (normative) Apparatus for dazzling test
    57 - Annex F (normative) Apparatus for impact test
    59 - Annex G (informative) Example of methane burner

    Abstract - (Show below) - (Hide below)

    Specifies the requirements, methods of test and performance criteria for point-type, resettable flame detectors that operate using radiation from a flame for use in fire detection systems installed in buildings.

    General Product Information - (Show below) - (Hide below)

    Committee FP-002
    Document Type Standard
    Publisher Standards Australia
    Revision Of
    Status Superseded
    Superseded By
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS 7240.10-2007.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 60068.2.78-2003 Environmental testing Tests - Test Cab: Damp heat, steady state (Reconfirmed 2018)
    AS 60068.2.27-2003 Environmental testing Tests - Test Ea and guidance: Shock
    AS 60068.1-2003 Environmental testing General and guidance (Reconfirmed 2018)
    AS 60068.2.52-2003 Environmental testing Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
    AS 60068.2.6-2003 Environmental testing Tests - Test Fc: Vibration (sinusoidal) (Reconfirmed 2018)
    AS/NZS 61000.4.4:2006 Electromagnetic compatibility (EMC) Testing and measurement techniques - Electrical fast transient/burst immunity test
    AS/NZS 61000.4.5:2006 Electromagnetic compatibility (EMC) Testing and measurement techniques - Surge immunity test
    AS 60068.2.42-2004 Environmental testing Tests - Test Kc: Sulphur dioxide test for contacts and connections (Reconfirmed 2018)
    AS 60068.2.10-2003 Environmental testing Tests - Test J and guidance: Mould growth
    AS 60068.2.30-2003 Environmental testing Tests - Test Db and guidance: Damp heat, cyclic (12 + 12-hour cycle)
    AS 60068.2.1-2003 Environmental testing Tests - Test A: Cold (Reconfirmed 2018)
    AS/NZS 61000.4.2:2002 Electromagnetic compatibility (EMC) Testing and measurement techniques - Electrostatic discharge immunity test

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 7240.20-2012 Fire detection and alarm systems Aspirating smoke detectors (Reconfirmed 2023)
    AS 7240.1-2007 Fire detection and alarm systems - General and definitions
    AS 4825-2011 Tunnel fire safety
    AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications