AS IEC 60601.1.10:2017
Current
The latest, up-to-date edition.
Medical electrical equipment General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
23-06-2017
The objective of this Standard is to improve the environmental impact for the entire range of medical equipment (ME), taking into account all stages of the product life cycle: product specification, design, manufacturing, sales, logistics, installation, use and end of life management.
Committee |
HE-003
|
DocumentType |
Standard
|
ISBN |
978 1 76035 821 1
|
Pages |
32
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS.This collateral standard specifies requirements for the development (analysis, design, VERIFICATION and VALIDATION) of a PHYSIOLOGIC CLOSED-LOOP CONTROLLER (PCLC) as part of a PHYSIOLOGIC CLOSED-LOOP CONTROL SYSTEM (PCLCS) in ME EQUIPMENT and ME SYSTEMS to control a PHYSIOLOGIC VARIABLE.NOTE A PHYSIOLOGIC VARIABLE can be a body chemistry (e.g. electrolytes, blood glucose), a physical property (e.g. PATIENT temperature, electrophysiologic, hemodynamic), or a pharmaceutical concentration.This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks.This collateral standard does not specify:- additional mechanical requirements; or- additional electrical requirements.This collateral standard applies to a closed-loop controller (see Figure 1) that sets the CONTROLLER OUTPUT VARIABLE in order to adjust (i.e., change or maintain) the measured PHYSIOLOGIC VARIABLE by relating it to the REFERENCE VARIABLE.A closed-loop controller that maintains a physical or chemical VARIABLE, using feedback that is not measured from a PATIENT, is outside the scope of this standard.
Standards | Relationship |
IEC 60601-1-10:2007+AMD1:2013 CSV | Identical |
First published as AS IEC 60601.1.10:2017.