Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV (Reconfirmed 2020)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
20-09-2024
09-12-2009
Specifies the design and test requirements for explosion-protected three-phase restrained plugs and receptacles incorporating three power contacts, one pilot contact and possibly one or more auxiliary contacts, an earth contact and an earthed phase barrier intended for use with restricted earth-fault systems in mines and quarries with a working voltage up to and including 3.3kV. Provision is also made for restrained back-to-back receptacles, which enable lengths of cable to be coupled together.
Committee |
EL-023
|
DevelopmentNote |
Under Revision by DR AS 1299:2021.
|
DocumentType |
Standard
|
ISBN |
0 7337 9329 0
|
Pages |
41
|
ProductNote |
Reconfirmed 11/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 11/09/2020 |
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies the design and test requirements for explosion-protected three-phase restrained plugs and receptacles incorporating three power contacts, one pilot contact and possibly one or more auxiliary contacts, an earth contact and an earthed phase barrier intended for use with restricted earth-fault systems in mines and quarries with a working voltage up to and including 3.3 kV. Provision is also made for restrained back-to-back receptacles, which enable lengths of cable to be coupled together.Restrained plugs and receptacles constructed to this Standard are not intended to be coupled or uncoupled while the circuit is energized.The Standard covers two types of restrained plugs and receptacles:(a) Type ADesigned according to Figures in this Standard that prescribe the dimensions necessary to interconnect plugs or receptacles from different manufacturers.(b) Type BDesigned to dimensions that are not compatible with Type A plugs or receptacles. Type B plugs or receptacles cannot be plugged into or accept a Type A plug or receptacle under normal operation. Type B plugs and receptacles do not comply with Figures 4.1 to 4.16 but comply with all other requirements of this Standard. Where there is a variation to a particular clause for Type B plugs and receptacles it is specifically stated. The use of transition devices between Type A and Type B systems is permitted.This Standard also deals with some electrical and mechanical requirements, including the provision of earthed phase barriers to protect against interphase faults. It does not specify fully detailed designs.This Standard provides for plug and receptacle discrimination, i.e. an arrangement whereby plugs and receptacles of different rated voltages or currents are physically prevented from being engaged. The requirements of AS/NZS 1747 should be considered in the design of these devices.NOTES:1 The term ‘receptacle’ as used in this Standard is synonymous with the term ‘socket-outlet’ in AS/NZS 3000. The term ‘receptacle’ has been chosen to avoid confusion with the individual sockets within the plug.2 Appendix A lists the information that a user should provide with any enquiry or order.3 Appendix C lists the information which should be supplied by the designer or manufacturer.4 A typical plug and receptacle (quick-release) assembly is shown in Figure 1.1 and a typical restrained back-to-back receptacle is shown in Figure 1.2.
Originated as AS 1299-1989.
Previous edition 1993.
Jointly revised and designated as AS/NZS 1299:2009.
Reissued incorporating Amendment No. 1 (March 2012).
AS/NZS 3008.1.2:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions |
AS 2700-1996 | Colour Standards for general purposes - Swatches |
AS/NZS 60079.7:2006 | Explosive atmospheres Equipment protection by increased safety 'e' |
AS/NZS 1802:2003 | Electric cables - Reeling and trailing - For underground coal mining purposes |
AS/NZS 1747:2003 | Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories (Reconfirmed 2020) |
AS/NZS 2802:2000 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020) |
AS 1856-2004 | Electroplated coatings - Silver |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 1972:2006 | Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020) |
AS 60529-2004 | Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018) |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
AS/NZS 60079.1:2007 | Explosive atmospheres Equipment protection by flameproof enclosures 'd' |
AS/NZS 60079.0:2008 | Explosive atmospheres Equipment - General requirements |
AS/NZS 60079.18:2005 | Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection encapsulation m electrical apparatus |
AS/NZS 3008.1.1:2009 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
SA/SNZ HB 146:2018 | Management of electrical cable in mines and quarries |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS/NZS 2290.1:2014 | Electrical equipment for coal mines - Introduction, inspection and maintenance For hazardous areas |
HB 239:2011 | Guidance on the repair and overhaul of electrical equipment for explosive atmospheres |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.