• AS/NZS 1530.7:1998

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Methods for fire tests on building materials, components and structures Smoke control door and shutter assemblies - Ambient and medium temperature leakage test procedure

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  27-04-2023

    Language(s):  English

    Published date:  05-11-1998

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 1530.7:1998 METHODS FOR FIRE TESTS ON BUILDING MATERIALS, COMPONENTS AND STRUCTURES - SMOKE CONTROL DOOR AND SHUTTER ASSE
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1 SCOPE AND GENERAL
    6 - 1.1 SCOPE
    6 - 1.2 APPLICATION
    6 - 1.3 OBJECTIVES
    6 - 1.4 REFERENCED DOCUMENTS
    6 - 1.5 DEFINITIONS
    6 - 1.5.1 Door and shutter assembly
    6 - 1.5.2 Smoke control door
    6 - 1.5.3 Ambient temperature
    6 - 1.5.4 Medium temperature
    6 - 1.5.5 Leakage rate
    7 - 1.5.6 Pressure difference
    7 - 1.5.7 Test specimen
    7 - 1.5.8 Associated construction
    7 - 1.5.9 Supporting construction
    7 - 1.6 SYMBOLS
    8 - SECTION 2 TEST METHOD
    8 - 2.1 SCOPE OF SECTION
    8 - 2.2 TEST APPARATUS
    8 - 2.3 INSTRUMENTATION
    8 - 2.3.1 Differential pressure
    8 - 2.3.2 Air temperature
    8 - 2.3.3 Airflow
    8 - 2.4 TEST SPECIMEN
    8 - 2.4.1 Number
    9 - 2.4.2 Size
    9 - 2.4.3 Construction
    9 - 2.4.4 Conditioning
    9 - 2.4.5 Pre-test analysis
    9 - 2.5 TEST PROCEDURE
    9 - 2.5.1 Setting-up procedure
    10 - 2.5.2 Air leakage test
    10 - 2.6 OBSERVATIONS
    10 - 2.6.1 Deformation
    11 - SECTION 3 REPORTING OF RESULTS
    11 - 3.1 EXPRESSION OF RESULTS
    11 - 3.1.1 General
    11 - 3.1.2 Measured values
    11 - 3.1.3 Standard conditions
    13 - 3.2 TEST REPORT
    14 - APPENDIX A - TEST PRINCIPLE
    15 - APPENDIX B - TEST APPARATUS
    15 - B1 TEST APPARATUS
    15 - B2 TEST CHAMBER

    Abstract - (Show below) - (Hide below)

    Sets out test procedures for a method of test for determining the smoke leakage through doors and shutters. This Standard is based on but not equivalent to ISO/CD 5925-1.

    Scope - (Show below) - (Hide below)

    This Standard sets out a method to measure the leakage of cold and warm smoke from one side of a door assembly to the other under the specified test conditions. The test can be applied to door and shutter assemblies of different types intended for purposes of controlling the passage of smoke in case of fire and of providing fire resistance.

    General Product Information - (Show below) - (Hide below)

    Committee FP-018
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS/NZS 1530.7:1998.

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
    AS 1905.2-2005 Components for the protection of openings in fire-resistant walls Fire-resistant roller shutters (Reconfirmed 2016)
    AS 1905.1-2005 Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
    AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
    AS 4072.1-2005 Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints (Reconfirmed 2016)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective