• Shopping Cart
    There are no items in your cart

AS/NZS 1604.4:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Specification for preservative treatment Laminated veneer lumber (LVL)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-07-2024

Published date

15-10-2004

€65.33
Excluding VAT

1 - AS/NZS 1604.4:2004 SPECIFICATION FOR PRESERVATIVE TREATMENT - LAMINATED VENEER LUMBER (LVL)
4 - PREFACE
6 - CONTENTS
7 - FOREWORD
8 - SECTION 1 SCOPE AND GENERAL
8 - 1.1 SCOPE
8 - 1.2 APPLICATION
8 - 1.3 REFERENCED DOCUMENTS
9 - 1.4 DEFINITIONS
9 - 1.4.1 Brand
9 - 1.4.2 Envelope treatment
9 - 1.4.3 Glueline treatment
9 - 1.4.4 Laminated veneer lumber (LVL)
9 - 1.4.5 Hazard class
9 - 1.4.6 Parcel
10 - 1.4.7 Penetration
10 - 1.4.8 Penetration zone
10 - 1.4.9 Preservative
10 - 1.4.10 Preservative number
10 - 1.4.11 Preservative treatment plant number
10 - 1.4.12 Veneer treatment
10 - 1.4.13 Retention
10 - 1.4.14 Treater
10 - 1.5 TIMBER PRESERVATIVES
10 - 1.6 PRODUCT REQUIREMENTS
11 - 1.7 SELECTION OF HAZARD CLASS
13 - 1.8 PRESERVATIVE TREATMENT
13 - 1.8.1 General
13 - 1.8.2 Penetration requirement
13 - 1.8.3 Penetration compliance
14 - 1.8.4 Retention of preservative
14 - 1.8.5 Retention compliance
14 - 1.8.6 Branding
14 - 1.9 USE IN NEW ZEALAND
15 - SECTION 2 HAZARD CLASS H1
15 - 2.1 GENERAL
15 - 2.2 PRESERVATIVE PENETRATION REQUIREMENT
15 - 2.3 PRESERVATIVE RETENTION REQUIREMENT
17 - SECTION 3 HAZARD CLASS H2
17 - 3.1 GENERAL
17 - 3.2 PRESERVATIVE PENETRATION REQUIREMENT
18 - 3.3 PRESERVATIVE RETENTION REQUIREMENT
19 - SECTION 4 HAZARD CLASS H3
19 - 4.1 GENERAL
19 - 4.2 PRESERVATIVE PENETRATION REQUIREMENT
19 - 4.3 PRESERVATIVE RETENTION REQUIREMENT
19 - 4.4 USE OF TBTN AND TBTO
21 - SECTION 5 HAZARD CLASS H4
21 - 5.1 GENERAL
21 - 5.2 PRESERVATIVE PENETRATION REQUIREMENT
22 - 5.3 PRESERVATIVE RETENTION REQUIREMENT
23 - SECTION 6 HAZARD CLASS H5
23 - 6.1 GENERAL
23 - 6.2 PRESERVATIVE PENETRATION REQUIREMENT
23 - 6.3 PRESERVATIVE RETENTION REQUIREMENT
25 - SECTION 7 MARKING
25 - 7.1 LEGIBLE MARKING
25 - 7.2 MARKING INFORMATION
25 - 7.2.1 General-Hazard classes H1 to H5
25 - 7.2.2 Hazard class H3
25 - 7.3 LAYOUT OF BRANDS
26 - 7.4 ADVISORY LABEL-ENVELOPE PENETRATION
26 - 7.5 USE RESTRICTION
26 - 7.6 COMPLIANCE TESTING
27 - APPENDIX A - GUIDE TO HAZARD CLASSIFICATIONS FOR VARIOUS END-USE APPLICATIONS
28 - APPENDIX B - METHOD OF SELECTION AND PREPARATION OF TEST SPECIMEN
28 - B1 SCOPE
28 - B2 SAMPLING PRESERVATIVE-TREATED PRODUCT
28 - B3 PREPARATION OF TEST SAMPLE
28 - B4 PENETRATION DETERMINATION

Provides specification for preservative treatment of laminated veneer lumber (LVL) for protection against decay or insect attack.

Committee
TM-006
DocumentType
Standard
ISBN
0 7337 6303 0
Pages
19
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out a specification for preservative treatment of laminated veneer lumber (LVL). It specifies the bond type, preservative penetration pattern, and the preservative retention requirements suitable for each hazard class (see Table 1).This Standard does not cover grade or seasoning condition.

First published as AS/NZS 1604.4:2002.
Second edition 2004.

AS 5604-2003 Timber - Natural durability ratings
AS 2754.1-1985 Adhesives for timber and timber products - Adhesives for plywood manufacture
AS 1604.1-2000 Specification for preservative treatment Sawn and round timber
AS/NZS 1605:2000 Methods for sampling and analysing timber preservatives and preservative-treated timber
AS/NZS 4357:1995 Structural Laminated Veneer Lumber
AS/NZS 4491:1997 Timber - Glossary of terms in timber-related Standards (Reconfirmed 2016)

AS 1684.3-2010 Residential timber-framed construction Cyclonic areas
AS 1684.4-2010 Residential timber-framed construction Simplified - Non-Cyclonic Areas
AS 1684.2-2010 Residential timber-framed construction Non-cyclonic areas
AS 5069-2006 Timber - Finger joints in non-structural products - Production requirements
AS 5604-2005 Timber - Natural durability ratings (Reconfirmed 2016)
AS 4997-2005 Guidelines for the design of maritime structures
AS 1684.2-2006 Residential timber-framed construction Non-cyclonic areas (SEE IMPORTANT NOTE)
AS/NZS 4357.0:2005 Structural laminated veneer lumber Specifications (Reconfirmed 2016)
AS 5068-2006 Timber - Finger joints in structural products - Production requirements (Reconfirmed 2016)
AS/NZS 1605.1:2006 Methods for sampling and analysing timber preservatives and preservative-treated timber General requirements, sampling, and determination of sapwood and heartwood presence
AS/NZS 1605.2:2006 Methods for sampling and analysing timber preservatives and preservative-treated timber Determination of preservative penetration by spot tests
AS/NZS 1605.4:2006 Methods for sampling and analysing timber preservatives and preservative-treated timber Analysis methods for determination of preservative solution concentration
AS/NZS 1605.3:2006 Methods for sampling and analysing timber preservatives and preservative-treated timber Analysis methods for determination of preservative retention
AS 4285-2007 Skylights
AS 1684.3-2006 Residential timber-framed construction Cyclonic areas
AS 1684.4-2006 Residential timber-framed construction - Simplified Non-cyclonic areas (SEE IMPORTANT NOTE)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.