AS/NZS 1660.5.5:2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Test methods for electric cables, cords and conductors Fire tests - Circuit integrity
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
23-02-2023
English
01-01-2005
Specifies the apparatus, procedures and performance requirements to be used for testing cables required to maintain circuit integrity when subjected to fire under specified conditions.
Committee |
EL-003
|
DocumentType |
Standard
|
ISBN |
0 7337 6669 2
|
Pages |
38
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies the test apparatus, the test procedure and the performance requirements to be used for testing cables of rated voltages up to 0.6/1.0kV, data cables and optical cables which are required to maintain circuit integrity when subject to fire alone. The test condition is based upon a flame with a controlled heat output corresponding to a temperature of a least 750°C.It also covers testing of cables of rated voltages up to 0.6/1.0kV when subject to fire and mechanical shock where the test condition is based upon a flame with a controlled heat output corresponding to a temperature of a nominal 850°C. This method is intended for use when testing cables of greater than 20mm overall diameter.
First published as AS/NZS 1660.5.5:1998.
Second edition 2005.
AS 60269.3.1-2005 | Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses |
AS/NZS 4507:2006 | Cables - Classification of characteristics when exposed to fire |
AS/NZS 60702.1:2005 | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables |
AS/NZS 3155:1995 | Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV |
AS 60092.376-2005 | Electrical installations in ships - Cables for control and instrumentation circuits 150/250 V (300 V) |
AS 60092.350-2005 | Electrical installations in ships Shipboard power cables - General construction and test requirements |
AS 60092.353-2005 | Electrical installations in ships Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1 kV and 3 kV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.