• AS/NZS 1660.5.6:2005

    AvailableSuperseded An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

    Test methods for electric cables, cords and conductors Fire tests - Test for vertical flame propagation for a single insulated wire or cable

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  04-05-2005

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Specifies a method of test for the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical cable under fire conditions.

    Scope - (Show below) - (Hide below)

    This Standard specifies the test apparatus and procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. It also specifies a test procedure for assessment of falling flaming droplets/particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions.

    History - (Show below) - (Hide below)

    First published in Australia as part of AS 1660.4-1974.Revised and designated in part as AS 1660.4-1986.Revised and redesignated in part as AS 1660.5.6-1993.Jointly revised and designated AS/NZS 1660.5.6:1998.Second edition 2005. Originated in Australia as part of AS 1660.4-1974. Jointly revised and designated as AS/NZS 1660.5.6:1998. Second edition 2005.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 60695.4-2006 Fire hazard testing - Terminology concerning fire tests for electrotechnical products
    AS/NZS 60695.11.2:2004 Fire hazard testing Test flames - 1 kW nominal pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
    AS/NZS 60695.4:2002 Fire hazard testing Terminology concerning fire tests (IEC 60695-4:1993, IDT)
    AS/NZS 4695.2.40:1996 Fire hazard testing of electrotechnical products Test methods - Diffusion type and premixed flame test methods

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/ACIF S008-2006 Requirements for customer cabling products
    AS/NZS 4507:2006 Cables - Classification of characteristics when exposed to fire
    AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
    AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017)
    AS/NZS 1995:2003 Welding cables (Reconfirmed 2017)
    AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
    AS/NZS 60840:2006 Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements
    AS/NZS 1972:2006 Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020)
    AS/NZS 60702.1:2005 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables
    AS/NZS 3155:1995 Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV
    AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
    AS/NZS 3191:2003 Electric flexible cords
    AS 3158-2004 Electric cables - Glass fibre insulated - For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2016)
    AS/NZS 1802:2018 Electric cables - Reeling and trailing - For underground coal mining
    AS 60092.376-2005 Electrical installations in ships - Cables for control and instrumentation circuits 150/250 V (300 V)
    AS/NZS 2276.1:2004 Cables for traffic signal installations Multicore power cables (Reconfirmed 2017)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective