• Shopping Cart
    There are no items in your cart

AS/NZS 1802:1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric cables - Reeling and trailing - For underground coal mining purposes

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-05-2018

Superseded by

AS/NZS 1802:2003

Language(s)

English

Published date

01-01-1995

€92.72
Excluding VAT

1 - AS/NZS 1802:1995 ELECTRIC CABLES - REELING AND TRAILING - FOR UNDERGROUND COAL MINING PURPOSES
4 - PREFACE
5 - CONTENTS
7 - FOREWORD
8 - 1 SCOPE
8 - 2 REFERENCED DOCUMENTS
8 - 3 DEFINITIONS
8 - 3.1 Approximate value
8 - 3.2 Bunch
8 - 3.3 Composite screen
8 - 3.4 Conductor covering
8 - 3.5 Conductor screen
9 - 3.6 Cradle separator
9 - 3.7 Direction of lay
9 - 3.8 Earth conductor
9 - 3.9 Fictitious diameter
9 - 3.10 Insulation screen
9 - 3.11 Length of lay
9 - 3.12 Maximum conductor temperature
9 - 3.13 Multiple-stranded conductor
9 - 3.14 Pilot/control core
9 - 3.15 Pitch circle diameter
9 - 3.16 Power core
9 - 3.17 Reeling and trailing cable
9 - 3.18 Routine tests
10 - 3.19 Special tests
10 - 3.20 Strand
10 - 3.21 Type tests
10 - 4 VOLTAGE DESIGNATION
10 - 5 DESIGNATION AND APPLICATION
11 - 6 MAXIMUM CONDUCTOR TEMPERATURES
12 - 7 POWER, EARTH AND PILOT CONDUCTORS (other than central pilot/ control cores and composite earth screens)
12 - 7.1 General
13 - 7.2 Joints
13 - 7.3 Direction of lay
13 - 7.4 Length of lay of bunches for interstitial conductors (Types 240, 241, 245, 260, 275, 280A and 280B only)
13 - 7.5 Resistance of earth and interstitial pilot conductors
14 - 8 CENTRAL PILOT/ CONTROL CORES (Types 209, 210, 241, 245, 275, 280A and 280B only)
14 - 8.1 Conductor material and resistance
14 - 8.2 Extensibility of pilot conductor
14 - 8.3 Central pilot/ control cores
14 - 8.4 Joints in central pilot/control conductor
14 - 8.5 Material and radial thickness of covering
14 - 8.6 Location
14 - 9 CONDUCTOR SCREEN
14 - 9.1 General
14 - 9.2 Material
15 - 9.3 Application
15 - 9.4 Thickness
15 - 9.5 Removal from conductor
15 - 9.6 Tests
15 - 9.7 Criteria
15 - 10 INSULATION OR COVERING ON CONDUCTORS (other than earth conductors)
15 - 10.1 Material
15 - 10.2 Application
15 - 10.3 Thickness
15 - 10.4 Tests
15 - 10.5 Criteria
17 - 11 TAPE OVER INSULATION OR COVERING, OTHER THAN SEMI-CONDUCTIVE TAPE (Types 209, 210, 240 and 260 only)
17 - 11.1 Material
17 - 11.2 Application
17 - 12 INSULATION SCREEN (non-metallic and composite)
17 - 12.1 General
17 - 12.2 Semiconductive elastomer screen
17 - 12.3 Textile reinforced semiconductive tape screen (Types 209, 240 and 260 only)
18 - 12.4 Textile reinforced semiconductive tape screen (Type 280B only)
18 - 12.5 Composite screen (Types 209, 210, 240 and 260 only)
19 - 13 IDENTIFICATION OF CORES
19 - 13.1 General
19 - 13.2 Identification method
19 - 13.3 Identification and rotational sequence
20 - 14 CRADLE SEPARATORS
20 - 14.1 Material
21 - 14.2 Freedom to move and provision for cradle separator fingers
21 - 15 SEMICONDUCTIVE ELASTOMER COVERING FOR INTERSTITIAL EARTH CONDUCTORS (Types 241, 245, 275, 280A and 280B only)
21 - 15.1 Material
21 - 15.2 Application
21 - 15.3 Thickness
21 - 16 LAYING UP OF CORES (other than Type 217)
21 - 17 SEMICONDUCTIVE ELASTOMER SCREEN FOR CORE ASSEMBLY (Types 241, 245, 275, 280A and 280B only)
21 - 17.1 Material
21 - 17.2 Application
21 - 17.3 Thickness
22 - 18 REINFORCEMENT FOR CORE ASSEMBLY (Types 217, 241, 245, 275, 280A and 280B only)
22 - 18.1 Type 217
22 - 18.2 Types 241, 245, 275, 280A and 280B
22 - 19 INNER SHEATH (Type 260 only)
22 - 19.1 Material
22 - 19.2 Application
22 - 19.3 Thickness
23 - 19.4 Tests
23 - 19.5 Criteria
23 - 20 PLIABLE ARMOUR (Type 260 only)
23 - 20.1 Material
23 - 20.2 Application
23 - 21 OUTER SHEATH (all cables)
23 - 21.1 Material
23 - 21.2 Colour
23 - 21.3 Application
23 - 21.4 Thickness
24 - 21.5 Tests
24 - 21.6 Criteria
24 - 22 OPTIONAL OUTER SHEATH REINFORCEMENT (Types 209, 240 and 260 only)
24 - 22.1 Material
24 - 22.2 Application
24 - 22.3 Location of reinforcement
24 - 23 CONSTRUCTION AND DIMENSIONS (All cables)
24 - 23.1 Construction
24 - 23.2 Nominal overall dimensions
24 - 23.3 Tolerance
26 - 24 JOINTS IN COMPLETED CABLE LENGTHS
26 - 25 TESTS
26 - 25.1 Testing- General requirements
29 - 25.2 Thickness of insulation, covering and sheath
30 - 25.3 Tests on semiconductive screens
32 - 25.4 High voltage a. c. test for 5 min on power cores and covered pilot conductors
32 - 25.5 Needle penetration test
34 - 25.6 Test for combustion propagation
34 - 26 FIGURES OF CONSTRUCTION AND TABLES OF DIMENSIONS
53 - 27 MARKING (all cables)
53 - 27.1 Internal
53 - 27.2 External
54 - 27.3 Marking of cable drums
55 - APPENDIX A - INFORMATION REQUIRED WITH ENQUIRY AND ORDER FOR REELING AND TRAILING CABLES
56 - APPENDIX B - DETERMINATION OF SHEATH THICKNESS AND PLIABLE ARMOUR STRAND SIZE USING FICTITIOUS CALCULATION METHOD
56 - B1 GENERAL
56 - B2 METHOD
56 - B2.1 Outer sheath
57 - B2.2 Inner sheath and armour (Type 260 only)
58 - APPENDIX C - MEASUREMENT OF VOLUME RESISTIVITY
58 - C1 SCOPE
58 - C2 PROCEDURE
58 - C3 CALCULATION
59 - APPENDIX D - NOTES ON DETERMINATION OF NOMINAL OVERALL DIMENSIONS OF CABLE
59 - D1 SCOPE
59 - D2 CALCULATED DIAMETERS OF TYPES 209, 210, 240, 241, 245, 260, 275, 280A AND 280B
59 - D2.1 Calculated power core diameter
59 - D2.2 Calculated diameter of the laid-up core assembly
59 - D2.3 Nominal overall diameter
59 - D3 CALCULATED DIAMETER OF TYPE 217
59 - D3.1 Calculated power core diameter
59 - D3.2 Calculated dimensions of core assembly
59 - D3.3 Nominal overall dimensions

Specifies the application, materials, construction, dimensions and tests for elastomer insulated and sheathed reeling and trailing electric cables, for use in underground coal mines.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 0162 0
Pages
54
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies elastomer-insulated, elastomer-sheathed reeling and trailing electric cables for use in underground coal mines. An essential feature of this Standard is the requirement that cables used for alternating current supply be electrically symmetrical.This Standard is intended to apply only to cables of the types provided for in the tables of construction and dimensions. It is not intended, however, that the use of other types or sizes of cables should be precluded, and regulatory authorities may give approval to new types as they are developed. Appropriate requirements for new types and sizes will eventually be included in this Standard as the need arises.This Standard also provides the basis of requirements for other sizes in the range of materials covered here.

First published in Australia as AS C81-1941.
Second edition 1950.
Redated 1952.
Third edition 1967.
Fourth edition 1973.
Revised and redesignated AS 1802-1976.
AS C81-1973 withdrawn 1978.
AS 1802-1976 revised in part and designated AS 1802-1985.
Third edition 1992.
Originated in New Zealand as NZS/AS 1802-1992.
Jointly revised and designated AS/NZS 1802:1995.

AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
HB 13-2000 Electrical equipment for hazardous areas
AS/NZS 1747:2003 Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories (Reconfirmed 2020)
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables (Reconfirmed 2017)
AS/NZS 4871.1:2002 Electrical equipment for coal mines, for use underground General requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.