• AS/NZS 1802:1995

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electric cables - Reeling and trailing - For underground coal mining purposes

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-05-2018

    Language(s):  English

    Published date:  01-01-1995

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 1802:1995 ELECTRIC CABLES - REELING AND TRAILING - FOR UNDERGROUND COAL MINING PURPOSES
    4 - PREFACE
    5 - CONTENTS
    7 - FOREWORD
    8 - 1 SCOPE
    8 - 2 REFERENCED DOCUMENTS
    8 - 3 DEFINITIONS
    8 - 3.1 Approximate value
    8 - 3.2 Bunch
    8 - 3.3 Composite screen
    8 - 3.4 Conductor covering
    8 - 3.5 Conductor screen
    9 - 3.6 Cradle separator
    9 - 3.7 Direction of lay
    9 - 3.8 Earth conductor
    9 - 3.9 Fictitious diameter
    9 - 3.10 Insulation screen
    9 - 3.11 Length of lay
    9 - 3.12 Maximum conductor temperature
    9 - 3.13 Multiple-stranded conductor
    9 - 3.14 Pilot/control core
    9 - 3.15 Pitch circle diameter
    9 - 3.16 Power core
    9 - 3.17 Reeling and trailing cable
    9 - 3.18 Routine tests
    10 - 3.19 Special tests
    10 - 3.20 Strand
    10 - 3.21 Type tests
    10 - 4 VOLTAGE DESIGNATION
    10 - 5 DESIGNATION AND APPLICATION
    11 - 6 MAXIMUM CONDUCTOR TEMPERATURES
    12 - 7 POWER, EARTH AND PILOT CONDUCTORS (other than central pilot/ control cores and composite earth screens)
    12 - 7.1 General
    13 - 7.2 Joints
    13 - 7.3 Direction of lay
    13 - 7.4 Length of lay of bunches for interstitial conductors (Types 240, 241, 245, 260, 275, 280A and 280B only)
    13 - 7.5 Resistance of earth and interstitial pilot conductors
    14 - 8 CENTRAL PILOT/ CONTROL CORES (Types 209, 210, 241, 245, 275, 280A and 280B only)
    14 - 8.1 Conductor material and resistance
    14 - 8.2 Extensibility of pilot conductor
    14 - 8.3 Central pilot/ control cores
    14 - 8.4 Joints in central pilot/control conductor
    14 - 8.5 Material and radial thickness of covering
    14 - 8.6 Location
    14 - 9 CONDUCTOR SCREEN
    14 - 9.1 General
    14 - 9.2 Material
    15 - 9.3 Application
    15 - 9.4 Thickness
    15 - 9.5 Removal from conductor
    15 - 9.6 Tests
    15 - 9.7 Criteria
    15 - 10 INSULATION OR COVERING ON CONDUCTORS (other than earth conductors)
    15 - 10.1 Material
    15 - 10.2 Application
    15 - 10.3 Thickness
    15 - 10.4 Tests
    15 - 10.5 Criteria
    17 - 11 TAPE OVER INSULATION OR COVERING, OTHER THAN SEMI-CONDUCTIVE TAPE (Types 209, 210, 240 and 260 only)
    17 - 11.1 Material
    17 - 11.2 Application
    17 - 12 INSULATION SCREEN (non-metallic and composite)
    17 - 12.1 General
    17 - 12.2 Semiconductive elastomer screen
    17 - 12.3 Textile reinforced semiconductive tape screen (Types 209, 240 and 260 only)
    18 - 12.4 Textile reinforced semiconductive tape screen (Type 280B only)
    18 - 12.5 Composite screen (Types 209, 210, 240 and 260 only)
    19 - 13 IDENTIFICATION OF CORES
    19 - 13.1 General
    19 - 13.2 Identification method
    19 - 13.3 Identification and rotational sequence
    20 - 14 CRADLE SEPARATORS
    20 - 14.1 Material
    21 - 14.2 Freedom to move and provision for cradle separator fingers
    21 - 15 SEMICONDUCTIVE ELASTOMER COVERING FOR INTERSTITIAL EARTH CONDUCTORS (Types 241, 245, 275, 280A and 280B only)
    21 - 15.1 Material
    21 - 15.2 Application
    21 - 15.3 Thickness
    21 - 16 LAYING UP OF CORES (other than Type 217)
    21 - 17 SEMICONDUCTIVE ELASTOMER SCREEN FOR CORE ASSEMBLY (Types 241, 245, 275, 280A and 280B only)
    21 - 17.1 Material
    21 - 17.2 Application
    21 - 17.3 Thickness
    22 - 18 REINFORCEMENT FOR CORE ASSEMBLY (Types 217, 241, 245, 275, 280A and 280B only)
    22 - 18.1 Type 217
    22 - 18.2 Types 241, 245, 275, 280A and 280B
    22 - 19 INNER SHEATH (Type 260 only)
    22 - 19.1 Material
    22 - 19.2 Application
    22 - 19.3 Thickness
    23 - 19.4 Tests
    23 - 19.5 Criteria
    23 - 20 PLIABLE ARMOUR (Type 260 only)
    23 - 20.1 Material
    23 - 20.2 Application
    23 - 21 OUTER SHEATH (all cables)
    23 - 21.1 Material
    23 - 21.2 Colour
    23 - 21.3 Application
    23 - 21.4 Thickness
    24 - 21.5 Tests
    24 - 21.6 Criteria
    24 - 22 OPTIONAL OUTER SHEATH REINFORCEMENT (Types 209, 240 and 260 only)
    24 - 22.1 Material
    24 - 22.2 Application
    24 - 22.3 Location of reinforcement
    24 - 23 CONSTRUCTION AND DIMENSIONS (All cables)
    24 - 23.1 Construction
    24 - 23.2 Nominal overall dimensions
    24 - 23.3 Tolerance
    26 - 24 JOINTS IN COMPLETED CABLE LENGTHS
    26 - 25 TESTS
    26 - 25.1 Testing- General requirements
    29 - 25.2 Thickness of insulation, covering and sheath
    30 - 25.3 Tests on semiconductive screens
    32 - 25.4 High voltage a. c. test for 5 min on power cores and covered pilot conductors
    32 - 25.5 Needle penetration test
    34 - 25.6 Test for combustion propagation
    34 - 26 FIGURES OF CONSTRUCTION AND TABLES OF DIMENSIONS
    53 - 27 MARKING (all cables)
    53 - 27.1 Internal
    53 - 27.2 External
    54 - 27.3 Marking of cable drums
    55 - APPENDIX A - INFORMATION REQUIRED WITH ENQUIRY AND ORDER FOR REELING AND TRAILING CABLES
    56 - APPENDIX B - DETERMINATION OF SHEATH THICKNESS AND PLIABLE ARMOUR STRAND SIZE USING FICTITIOUS CALCULATION METHOD
    56 - B1 GENERAL
    56 - B2 METHOD
    56 - B2.1 Outer sheath
    57 - B2.2 Inner sheath and armour (Type 260 only)
    58 - APPENDIX C - MEASUREMENT OF VOLUME RESISTIVITY
    58 - C1 SCOPE
    58 - C2 PROCEDURE
    58 - C3 CALCULATION
    59 - APPENDIX D - NOTES ON DETERMINATION OF NOMINAL OVERALL DIMENSIONS OF CABLE
    59 - D1 SCOPE
    59 - D2 CALCULATED DIAMETERS OF TYPES 209, 210, 240, 241, 245, 260, 275, 280A AND 280B
    59 - D2.1 Calculated power core diameter
    59 - D2.2 Calculated diameter of the laid-up core assembly
    59 - D2.3 Nominal overall diameter
    59 - D3 CALCULATED DIAMETER OF TYPE 217
    59 - D3.1 Calculated power core diameter
    59 - D3.2 Calculated dimensions of core assembly
    59 - D3.3 Nominal overall dimensions

    Abstract - (Show below) - (Hide below)

    Specifies the application, materials, construction, dimensions and tests for elastomer insulated and sheathed reeling and trailing electric cables, for use in underground coal mines.

    Scope - (Show below) - (Hide below)

    This Standard specifies elastomer-insulated, elastomer-sheathed reeling and trailing electric cables for use in underground coal mines. An essential feature of this Standard is the requirement that cables used for alternating current supply be electrically symmetrical.This Standard is intended to apply only to cables of the types provided for in the tables of construction and dimensions. It is not intended, however, that the use of other types or sizes of cables should be precluded, and regulatory authorities may give approval to new types as they are developed. Appropriate requirements for new types and sizes will eventually be included in this Standard as the need arises.This Standard also provides the basis of requirements for other sizes in the range of materials covered here.

    General Product Information - (Show below) - (Hide below)

    Committee EL-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    Under Revision see DR 02505 First published in Australia as AS C81-1941.Second edition 1950.Redated 1952.Third edition 1967.Fourth edition 1973.Revised and redesignated AS 1802-1976.AS C81-1973 withdrawn 1978.AS 1802-1976 revised in part and designated AS 1802-1985.Third edition 1992. Originated in New Zealand as NZS/AS 1802-1992. Jointly revised and designated AS/NZS 1802:1995. First published in Australia as AS C81-1941. Second edition 1950. Redated 1952. Third edition 1967. Fourth edition 1973. Revised and redesignated AS 1802-1976. AS C81-1973 withdrawn 1978. AS 1802-1976 revised in part and designated AS 1802-1985. Third edition 1992. Originated in New Zealand as NZS/AS 1802-1992. Jointly revised and designated AS/NZS 1802:1995.

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
    AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
    AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
    HB 13-2000 Electrical equipment for hazardous areas
    AS/NZS 1747:2003 Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories (Reconfirmed 2020)
    AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
    AS/NZS 4871.1:2002 Electrical equipment for coal mines, for use underground General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective