• Shopping Cart
    There are no items in your cart

AS/NZS 3004.2:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical installations - Marinas and recreational boats Recreational boats installations

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

19-11-2008

Superseded date

21-04-2025

Superseded by

AS/NZS 3004.2:2014

€110.01
Excluding VAT
Summarise this standard

1 - AS/NZS 3004.2:2008 ELECTRICAL INSTALLATIONS-MARINAS AND RECREATIONAL BOATS - RECREATIONAL BOATS INSTALLATIONS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
8 - 1.2 APPLICATION
9 - SECTION 2 REFERENCED DOCUMENTS
12 - SECTION 3 DEFINITIONS
12 - 3.1 GENERAL
12 - 3.1.1 Safety voltage
12 - 3.1.2 Essential services
13 - 3.1.3 Boat’s earth
13 - 3.1.4 Engine negative terminal
13 - 3.2 d.c. SYSTEMS OF DISTRIBUTION
13 - 3.2.1 Two-wire d.c. system
13 - 3.2.2 Three-wire d.c. system
13 - 3.3 a.c. SYSTEMS OF DISTRIBUTION
13 - 3.3.1 Single-phase two-wire a.c. system
13 - 3.3.2 Single-phase three-wire a.c. system
13 - 3.3.3 Three-phase three-wire system
13 - 3.3.4 Three-phase four-wire system
13 - 3.3.5 Three-phase five-wire system
13 - 3.4 PROTECTION
13 - 3.4.1 Circuit-breaker
14 - 3.4.2 Equipotential bond
14 - 3.4.3 Final subcircuit
14 - 3.4.4 Fuse
14 - 3.4.5 Low-voltage switchgear and controlgear
14 - 3.4.6 Neutral (neutral conductor or mid-wire)
14 - 3.4.7 Overcurrent protection device
14 - 3.4.8 Protective earthing conductor
14 - 3.4.9 Residual current device (RCD)
14 - 3.4.10 Sheath
15 - 3.5 EQUIPMENT
15 - 3.5.1 Accessible, readily
15 - 3.5.2 Battery
15 - 3.5.3 Cable trunking
15 - 3.5.4 Captive-spade terminal
15 - 3.5.5 Certified safe for explosive gas atmospheres type equipment
15 - 3.5.6 Galvanic isolator
15 - 3.5.7 Generator
16 - 3.5.8 Ignition protection
16 - 3.5.9 Shore power inlet
16 - 3.5.10 Transformer
17 - SECTION 4 GENERAL REQUIREMENTS
17 - 4.1 RATINGS
17 - 4.2 AMBIENT AIR AND COOLING WATER TEMPERATURE
17 - 4.3 INCLINATION OF BOAT
18 - 4.4 VOLTAGE AND FREQUENCY VARIATIONS
18 - 4.4.1 General
18 - 4.4.2 d.c. systems
18 - 4.4.3 a.c. systems
18 - 4.4.4 Adverse effects and its interference
19 - 4.5 ELECTRICAL POWER SOURCES
19 - 4.5.1 General
19 - 4.5.2 d.c. systems supplied from batteries
19 - 4.5.3 d.c. generator
20 - 4.5.4 a.c. systems
21 - 4.5.5 a.c. generator
21 - 4.5.6 Measuring instruments
22 - 4.6 EQUIPMENT
22 - 4.6.1 Transformers
22 - 4.6.2 Converters
23 - 4.6.3 Inverters and inverter/chargers
24 - 4.6.4 Galvanic isolator
24 - 4.7 EQUIPMENT CONSTRUCTION
24 - 4.7.1 General requirement
24 - 4.7.2 General degree of protection of equipment and enclosures
25 - 4.7.3 Protection from dripping water
25 - 4.7.4 Cable entry
25 - 4.7.5 Identification
25 - 4.7.6 Segregation of d.c and a.c. systems and systems of different voltages
26 - 4.7.7 Busbars
26 - 4.7.8 Switches and controls
26 - 4.7.9 Final subcircuits
26 - 4.8 PLUGS AND SOCKET-OUTLETS
26 - 4.8.1 a.c. system
27 - 4.8.2 Mixed a.c and d.c. systems
27 - 4.8.3 Installation in special locations
27 - 4.9 BATTERY INSTALLATION
27 - 4.9.1 General arrangements
27 - 4.9.2 Ventilation
28 - 4.10 BATTERY CHARGERS
28 - 4.10.1 General
28 - 4.10.2 Protection against overcharging
28 - 4.10.3 Wind generator and photovoltaic devices
28 - 4.11 INTERNAL COMMUNICATION CIRCUITS
28 - 4.12 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES
29 - 4.13 ELECTRICAL FITTINGS AND CABLES ATTACHED TO STRUCTURES OF ANOTHER METAL
29 - 4.14 NAVIGATION LIGHTS SUPPLY
29 - 4.15 LUMINAIRES
29 - 4.16 ELECTRICAL HEATING AND COOKING APPLIANCES
29 - 4.17 MAGNETIC COMPASSES
30 - SECTION 5 DISTRIBUTION SYSTEMS
30 - 5.1 d.c. DISTRIBUTION SYSTEMS
30 - 5.2 STANDARD a.c. DISTRIBUTION SYSTEMS
30 - 5.2.1 Types of a.c. distribution system
30 - 5.2.2 Earthing the neutral conductor in type TN a.c. systems
31 - 5.2.3 Earthing of non current-carrying parts in a.c. systems
31 - 5.2.4 Protective conductor in a.c. systems
31 - 5.3 EQUIPOTENTIAL BONDING CONDUCTORS
32 - 5.4 BALANCE OF LOADS IN THREE-PHASE a.c. SYSTEMS
32 - 5.5 SHORE CONNECTION ARRANGEMENTS
32 - 5.5.1 General
32 - 5.5.2 Boat connections
34 - 5.5.3 Changeover switch for a boat with its own a.c. power system
34 - 5.5.4 Information and connection instructions
34 - 5.5.5 Supply through an on-shore mounted isolating transformer
35 - 5.5.6 Supply through an on-board isolating transformer or converter
35 - 5.5.7 Supply without an isolating transformer
35 - 5.6 SWITCHBOARD
35 - 5.6.1 General
36 - 5.6.2 For d.c. systems
36 - 5.6.3 For a.c. systems
37 - SECTION 6 PROTECTION AGAINST ELECTRIC SHOCK IN a.c. SYSTEMS WITH VOLTAGE EXCEEDING 50 V
37 - 6.1 PROTECTION AGAINST DIRECT CONTACT
37 - 6.2 AUTOMATIC DISCONNECTION OF SUPPLY TO FINAL SUBCIRCUITS OR EQUIPMENT
37 - 6.3 EARTHED NEUTRAL SYSTEMS
37 - 6.4 NON-NEUTRAL EARTHED SYSTEM (IT TYPE SYSTEM)
38 - 6.5 USE OF CLASS II EQUIPMENT
38 - 6.6 UNACCEPTABLE MEASURES AGAINST ELECTRIC SHOCK
39 - SECTION 7 PROTECTION AGAINST OVERCURRENT
39 - 7.1 GENERAL
39 - 7.2 CHARACTERISTICS OF PROTECTIVE DEVICES
39 - 7.3 d.c. SYSTEM
39 - 7.3.1 Protective devices
40 - 7.3.2 Final subcircuits
40 - 7.4 a.c. SYSTEM
40 - 7.4.1 Protective devices
40 - 7.4.2 Final subcircuits
40 - 7.5 GENERATORS
40 - 7.5.1 Small generators in d.c. systems
40 - 7.5.2 Use of fuses
40 - 7.5.3 Generator circuit-breaker
40 - 7.6 TRANSFORMERS
41 - 7.7 MOTOR PROTECTION
42 - SECTION 8 PROTECTION AGAINST EARTH LEAKAGE CURRENT IN a.c. SYSTEMS
42 - 8.1 GENERAL
42 - 8.2 SELECTION OF DEVICES FOR PROTECTION AGAINST EARTH LEAKAGE
43 - SECTION 9 CABLES
43 - 9.1 SELECTION OF CABLES FOR MARINE ENVIRONMENT
43 - 9.2 CABLE SELECTION AND INSTALLATION
43 - 9.3 PROTECTIVE COVERINGS
43 - 9.3.1 Environmental conditions
43 - 9.3.2 Mechanical strength
43 - 9.3.3 Minimization of thermal effects
43 - 9.4 DETERMINATION OF THE CROSS-SECTIONAL AREAS OF CONDUCTORS
43 - 9.4.1 General requirement
44 - 9.4.2 d.c. system
44 - 9.4.3 a.c. system
44 - 9.4.4 Protective conductor in a.c. system
44 - 9.4.5 Current ratings for continuous service
45 - 9.4.6 Correction factors for different ambient air temperatures
46 - 9.4.7 Correction factors for cable bunching
46 - 9.4.8 Correction factors for non-continuous service
46 - 9.4.9 Parallel connection of cables
47 - 9.4.10 Segregation of circuits
48 - SECTION 10 CABLE AND WIRING INSTALLATION AND TERMINATION
48 - 10.1 EQUIPOTENTIAL BONDS
48 - 10.1.1 Enclosures for electrical equipment in a.c systems
48 - 10.1.2 Earthing of the protective conductor in non-metal boats
48 - 10.2 CABLE TERMINATIONS
49 - 10.3 CABLE AND CONDUCTOR INSTALLATION
49 - 10.3.1 Protection from damage
49 - 10.3.2 Cable and conductor runs
49 - 10.3.3 Cable and conductor support and protection
50 - 10.4 d.c. AND a.c. CABLING AND WIRING SEGREGATION
50 - 10.5 CONDUCTOR IDENTIFICATION
50 - 10.5.1 General
50 - 10.5.2 Equipotential bonding conductors
51 - 10.5.3 d.c. conductor insulation colours
51 - 10.6 LIGHTNING PROTECTION
51 - 10.6.1 General
51 - 10.6.2 Conductors
51 - 10.6.3 Installation
51 - 10.6.4 Interconnection
51 - 10.6.5 Earthing
52 - SECTION 11 VERIFICATION
52 - 11.1 GENERAL
52 - 11.2 EARTHING
52 - 11.3 INSULATION RESISTANCE
52 - 11.3.1 Measurements
52 - 11.3.2 Switchboards, panel boards and distribution boards
53 - 11.3.3 Lighting and power circuits
53 - 11.3.4 Generators and motors
53 - 11.3.5 Transformers
53 - 11.4 SWITCHGEAR AND CONTROLGEAR
53 - 11.5 VOLTAGE DROP
53 - 11.6 INTERNAL COMMUNICATION CIRCUITS
53 - 11.7 LIGHTING, HEATING AND GALLEY EQUIPMENT
54 - APPENDIX A - RECREATIONAL BOATS OVER 24 METRES AND LARGER VESSELS OPERATIONAL IN OFFSHORE WATERS
54 - A1 GENERAL
54 - A2 ESSENTIAL SERVICES
54 - A3 BATTERY CAPACITIES
54 - A4 EARTHING
54 - A4.1 General
55 - A4.2 Earthed neutral systems (TN type systems)
55 - A4.3 Non-earthed system (IT type system)
55 - A5 SEGREGATION OF CIRCUITS
55 - A6 BATTERY CHARGER PROTECTION
55 - A7 PROTECTION AGAINST OVERCURRENT AND FAULT CURRENT-SPECIAL APPLICATIONS
55 - A8 NAVIGATION LIGHT SUPPLY
55 - A9 RADIO AND NAVIGATION EQUIPMENT
55 - A10 NAVIGATION, CONTROL, INSTRUMENTATION AND COMMUNICATION SYSTEMS
56 - A11 ELECTRIC AND ELECTRO-HYDRAULIC STEERING GEAR
56 - A12 ELECTROMAGNETIC COMPATIBILITY
57 - APPENDIX B - SHORE SIDE ARRANGEMENTS
57 - B1 SHORE POWER SUPPLY ARRANGEMENTS
57 - B1.1 General
57 - B1.2 Instructions
59 - B2 EXAMPLES OF GENERAL ARRANGEMENTS FOR ELECTRICITY SUPPLY TO A BOAT (FUNCTIONAL SWITCHES NOT SHOWN)
59 - B2.1 Connection to single-phase mains supply
59 - B2.2 Connection to three-phase mains supply
60 - B2.3 Single-phase on-shore mounted isolating transformer (hull and metal parts bonded)
60 - B2.4 Supply through an on-board isolating transformer
61 - APPENDIX C - PERIODIC TESTING
61 - C1 REPORTING OF ELECTRICALLY UNSAFE INSTALLATIONS
61 - C2 PREVIOUS RECORDS
61 - C3 VERIFICATION REQUIREMENTS
61 - C4 DANGER TO PERSONS OR LIVESTOCK
61 - C5 ADEQUACY OF OVERCURRENT PROTECTIVE DEVICES
61 - C6 INSTRUMENTS
62 - C7 QUALIFICATION
62 - C8 FREQUENCY OF PERIODIC VERIFICATION
62 - C9 REPORTING OF PERIODIC VERIFICATION
63 - C10 VERIFICATION BY BASIC VISUAL INSPECTION
63 - C10.1 General
63 - C10.2 Inspection requirements
66 - C11 VERIFICATION BY TESTING
66 - C11.1 General
66 - C11.2 Testing requirements
69 - APPENDIX D - RECREATIONAL BOATS WARRANT OF ELECTRICAL FITNESS CERTIFICATION FORM-NEW ZEALAND ONLY

Specifies requirements for electrical installations on small boats (viz boats with a maximum length of 50m).

Committee
EL-001
DocumentType
Standard
ISBN
0 7337 8942 0
Pages
63
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Part of AS/NZS 3004 specifies requirements for the design, construction and installation of electrical systems in recreational boats that have a length of up to 50 m, and are designed for use on inland waters or at sea. It is not intended to apply to small boats equipped with a battery supplying circuits for engine starting and navigation lighting only that are recharged from an inboard or outboard engine driven alternator.NOTES:1 Attention is drawn to the International Regulations for the Preventing of Collisions at Sea, 1972 (COLREG) as amended, which govern specific requirements for navigation lights for boats.2 Attention is drawn to regulations in Australia and New Zealand which govern specific requirements for the safety of electronic and electrical equipment; electromagnetic compatibility requirements; marine safety requirements; energy and water usage; telecommunications and radio communication requirements.3 For high speed boats, attention is drawn to the Australian National Standard for Commercial Vessels (NSCV), Part F: Special vessels, Section 1: Fast craft and the New Zealand Maritime Rules.This Standard applies to the following types of d.c. and a.c. electrical systems, individually or in combination:(a) Direct current systems which operate at a nominal voltage not exceeding 1500 V.NOTE: For example, for many small recreational boats this will be the main electrical system. Alternatively a boat equipped with an a.c. system as its principal electrical system may be also equipped with a d.c. system for navigation and communications equipment supplied from batteries.(b) Single-phase alternating current systems which operate at a nominal voltage not exceeding 1000 V.NOTE: Such a system may be the principal electrical power system of a recreational boat, or a system which may only be energized when connected to a shore supply, a.c. extra-low voltage, safety extra-low voltage etc. circuits may also comprise part of a single-phase a.c. system. A boat may also be equipped with d.c. system(s) as in (a) above.(c) Three-phase alternating current systems which operate at a nominal voltage not exceeding 1000 V.NOTE: Three-phase systems are likely to be the principal electrical power system of a recreational boat’s electrical installation. Such a boat may also be equipped with single-phase a.c. subsystem(s) and d.c. subsystem(s).Recreational boats whose electrical installation complies with the requirements of an international maritime classification society which is recognized by AMSA or New Zealand Maritime can be used to show compliance where appropriate with this Standard.NOTE: Exemptions based on the above paragraph must be supported by appropriate and current certification.

Originated as part of AS 3004-1979.
Previous edition part of AS/NZS 3004:2002.
Jointly revised and redesignated (in part) as AS/NZS 3004.2:2008.

⚠

A newer version of this standard is available.

View Current Edition
€110.01
Excluding VAT