AS/NZS 3008.1.1:2017
Current
The latest, up-to-date edition.
Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
02-02-2017
AS NZS 3008.1.1 2017 sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.
Committee |
EL-001
|
DocumentType |
Standard
|
ISBN |
978 1 76035 658 3
|
Pages |
139
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.NOTE: Although the Standard specifically applies to a.c. installations, it may also be applied to d.c. installations.Four criteria are given for cable selection, as follows:(a) Current carrying capacity.(b) Voltage drop.(c) Short-circuit temperature rise.(d) Economic optimization.This Standard provides sustained current-carrying capacities and voltage drop values for those types of electrical cable and installation practices in common use in Australia. A significant amount of explanatory material is also provided on the application of rating factors that arise from the particular installation conditions of a single circuit or groups of circuits. Also, provided in Section 5 is information on cable selection based on short-circuit temperature limits.NOTE: A number of worked examples on cable selection are included in Appendix A.This Standard does not take into account the effects that may occur owing to temperature rise at the terminals of equipment and reference is necessary to AS/NZS 3000 and the individual equipment Standards.NOTE: For ease of reference, an index of the Tables included in this Standard is provided in Appendix B.
Originated in Australia as AS 3008.1-1984.
Originated in New Zealand as AS/NZS 3008.1.1:1998.
Previous edition 2009.
This edition 2017.
AS/NZS 3008.1.2:2010 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
AS/NZS 4961:2003 | Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 60702.1:2005 | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables |
AS/NZS 4026:2008 | Electric cables - For underground residential distribution systems |
AS/NZS 5000.2:2006 | Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017) |
AS/NZS 3191:2008 | Electric flexible cords (Reconfirmed 2019) |
AS/NZS 3560.1:2000 | Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021) |
AS/NZS 5000.3:2003 | Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017) |
AS/NZS 1125:2001 | Conductors in insulated electric cables and flexible cords (Reconfirmed 2017) |
AS 1531-1991 | Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016) |
AS/NZS 3560.2:2003 | Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors |
AS 3158-2004 | Electric cables - Glass fibre insulated - For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2016) |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
AS 1746-1991 | Conductors - Bare overhead - Hard-drawn copper |
AS/NZS 3003:2018 | Electrical installations - Patient areas |
AS/NZS 5139:2019 | Electrical installations - Safety of battery systems for use with power conversion equipment |
AS/NZS 3008.1.2:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.