• AS/NZS 3008.1.1:2017

    Current The latest, up-to-date edition.

    Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  02-02-2017

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    AS NZS 3008.1.1 2017 sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.

    Scope - (Show below) - (Hide below)

    This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.NOTE: Although the Standard specifically applies to a.c. installations, it may also be applied to d.c. installations.Four criteria are given for cable selection, as follows:(a) Current carrying capacity.(b) Voltage drop.(c) Short-circuit temperature rise.(d) Economic optimization.This Standard provides sustained current-carrying capacities and voltage drop values for those types of electrical cable and installation practices in common use in Australia. A significant amount of explanatory material is also provided on the application of rating factors that arise from the particular installation conditions of a single circuit or groups of circuits. Also, provided in Section 5 is information on cable selection based on short-circuit temperature limits.NOTE: A number of worked examples on cable selection are included in Appendix A.This Standard does not take into account the effects that may occur owing to temperature rise at the terminals of equipment and reference is necessary to AS/NZS 3000 and the individual equipment Standards.NOTE: For ease of reference, an index of the Tables included in this Standard is provided in Appendix B.

    General Product Information - (Show below) - (Hide below)

    Committee EL-001
    Document Type Standard
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    Originated in Australia as AS 3008.1—1984.Originated in New Zealand as AS/NZS 3008.1.1:1998.Previous edition 2009.This edition 2017. Originated in Australia as AS 3008.1-1984. Originated in New Zealand as AS/NZS 3008.1.1:1998. Previous edition 2009. This edition 2017.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 3008.1.2:2010 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
    AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
    AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS/NZS 60702.1:2005 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables
    AS/NZS 4026:2008 Electric cables - For underground residential distribution systems
    AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017)
    AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
    AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
    AS/NZS 5000.3:2003 Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017)
    AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
    AS 1531-1991 Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)
    AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors
    AS 3158-2004 Electric cables - Glass fibre insulated - For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2016)
    AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
    AS 1746-1991 Conductors - Bare overhead - Hard-drawn copper

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3003:2018 Electrical installations - Patient areas
    AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
    AS/NZS 3008.1.2:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
    AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective