AS/NZS 3111:2009
Current
The latest, up-to-date edition.
Approval and test specification - Miniature overcurrent circuit-breakers (Reconfirmed 2020)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
21-01-2009
Specifies essential safety requirements for approval and test purposes for miniature overcurrent circuit-breakers. It is intended to be read in conjunction with AS/NZS3100.
Committee |
EL-004
|
DocumentType |
Standard
|
ISBN |
0 7337 8993 5
|
Pages |
16
|
ProductNote |
Reconfirmed 18/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 18/09/2020 |
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes | |
UnderRevision |
This Standard applies to miniature overcurrent air-break circuit-breakers, referred to hereinafter as ‘circuit-breaker(s)’, having the following characteristics: (a) Intended for the prevention of continued overloading of electrical circuit wiring. (b) Having current ratings up to, and including, 125 A. (c) Having current breaking capacities up to, and including, 10 kA. (d) Intended for use at low voltage. A circuit-breaker intended only for the protection of electrical equipment as distinct from circuit wiring, and that is appropriately marked as such, is not within the scope of this Standard. NOTES:1 Voltages and currents referred to in this Standard relate to alternating currents except where otherwise specified and values quoted are r.m.s. values.2 Attention is drawn to AS/NZS 60947.2, which covers circuit-breakers having breaking capacities above 3 kA.
First published as AS C111-1938.
Revised and redesignated as AS 3111 in 1974.
Fourth edition 1994.
Revised and redesignated as AS/NZS 3111:2009.
Reissued incorporating Amendment No. 1 (October 2011).
Reissued incorporating Amendment No. 2 (June 2015).
AS/NZS 3121:2002 | Approval and test specification - Insulating mouldings (Reconfirmed 2020) |
AS/NZS 60898.1:2004 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. operation (IEC 60898-1, Ed. 1.2 (2003) MOD) |
AS/NZS 3190:2002 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 60947.2-2005 | Low-voltage switchgear and controlgear - Circuit-breakers |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 3012:2010 | Electrical installations - Construction and demolition sites |
AS/NZS 3003:2018 | Electrical installations - Patient areas |
AS/NZS 3105:2012 | Approval and test specification - Electrical portable outlet devices |
AS/NZS 3003:2011 | Electrical installations - Patient areas |
AS/NZS 3190:2009 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 2676.2:2020 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings Sealed cells |
AS/NZS 3105:2014 | Approval and test specification - Electrical portable outlet devices |
AS 2676.1:2020 | Installation, maintenance, testing and replacement of secondary batteries in buildings Vented cells |
AS/NZS 3190:2016 | Approval and test specification - Residual current devices (current operated earth-leakage devices) |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3190:2011 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.