• AS/NZS 3200.2.21:1994

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Approval and test specification - Medical electrical equipment - Particular requirements for safety - Infant radiant warmers

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-10-2017

    Language(s): 

    Published date:  01-01-1994

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 3200.2.21:1994 APPROVAL AND TEST SPECIFICATION - MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - INFA
    4 - PREFACE
    5 - CONTENTS
    7 - SECTION ONE - GENERAL
    7 - 1 Scope and object
    8 - 2 Terminology and definitions
    10 - 3 General requirements
    11 - 4 General requirements for tests
    11 - 6 Identification, marking and documents
    13 - SECTION TWO - ENVIRONMENTAL CONDITIONS
    13 - 10 Environmental conditions
    13 - SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
    13 - 20 Dielectric strength
    14 - SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
    14 - 21 Mechanical strength
    14 - 24 Stability in NORMAL USE
    15 - SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION
    15 - 33* Infra-red radiation
    15 - 36 ELECTROMAGNETIC COMPATIBILITY
    15 - SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
    15 - SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS
    15 - 42 Excessive temperature
    17 - 43 Fire prevention
    18 - 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
    18 - 46 Human errors
    19 - 49 Interruption of the power supply
    19 - SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
    19 - 50 Accuracy of operating data
    21 - SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS
    21 - SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
    21 - 54 General
    21 - 56 Components and general assembly
    24 - SECTION 101 - ADDITIONAL REQUIREMENTS
    24 - 101 Alarms
    24 - 102 Sound pressure level
    25 - 103 Concentration of carbon dioxide
    28 - Appendices/Annexes
    28 - Appendix L - References – Publications mentioned in this standard
    29 - APPENDIX ZZ - VARIATIONS TO IEC 601-2-21 FOR APPLICATION IN AUSTRALIA AND NEW ZEALAND
    30 - Annex AA - General guidance and rationale
    36 - Annex BB - BIBLIOGRAPHY

    Abstract - (Show below) - (Hide below)

    Applies to infant warmers using a radiant heating source. The device is intended to maintain the thermal balance of an infant patient by direct radiation of energy in the infra-red region of the electromagnetic spectrum. This Standard is to be read in conjunction with AS 3200.1.0-1990. It is identical with and reproduced from IEC 601-2-21:1994.

    Scope - (Show below) - (Hide below)

    Addition:This Particular Standard applies to INFANT RADIANT WARMERS as defined in 2.2.101.

    General Product Information - (Show below) - (Hide below)

    Committee HE-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Under Revision

    History - (Show below) - (Hide below)

    Amendment 1 to AS/NZS 3200.2.21:1994 see DR 97237 First published as Joint Standard AS/NZS 3200.2.21:1994.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 3200.1.0-1998 Medical electrical equipment General requirements for safety - Parent Standard
    AS 1259.1-1990 Acoustics - Sound level meters Non-integrating

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 60335.2.90:2006 Household and Similar Electrical Appliances - Safety Particular requirements for commercial microwave ovens
    AS/NZS 60745.1:2009 Hand-held motor-operated electric tools-Safety General requirements (IEC 60745-1 Ed 4, MOD) (Reconfirmed 2020)
    AS 4774.2-2002 Work in compressed air and hyperbaric facilities - Hyperbaric oxygen facilities
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective