• Shopping Cart
    There are no items in your cart

AS/NZS 3200.2.25:1993

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Approval and test specification - Medical electrical equipment Particular requirements for safety - Electrocardiographs

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-07-2024

Language(s)

English

Published date

20-12-1993

€65.33
Excluding VAT

1 - AS/NZS 3200.2.25:1993 APPROVAL AND TEST SPECIFICATION-MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY-ELECTROC
4 - PREFACE
7 - SECTION ONE - GENERAL
7 - 1 Scope and object
7 - 1.1 Scope
7 - 1.2 Object
7 - 1.3 Particular Standards
8 - 2 Terminology and definitions
9 - 4 General requirements for tests
10 - 5 Classification
10 - 6 Identification, marking and documents
11 - SECTION TWO - ENVIRONMENTAL CONDITIONS
11 - 10 Environmental conditions
11 - SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
11 - 17 Separation
12 - 19 Continuous leakage currents and patient auxiliary currents
13 - 20 Dielectric strength
13 - SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
13 - SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION
13 - 34 Ultraviolet radiation
13 - SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
13 - SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS
14 - 42 Excessive temperatures
14 - 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
14 - SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
14 - 51 Protection against hazardous output
17 - SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS
17 - SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
18 - 57 Mains parts, components and layout
24 - APPENDIX DD - Symbols on marking
25 - APPENDIX ZZ - VARIATIONS TO IEC 601-2-25 FOR APPLICATION IN AUSTRALIA AND NEW ZEALAND
27 - Annex AA - General guidance and rationale
27 - Use with defibrillator
27 - Rationale for defibrillator test voltages
28 - Summary
28 - Specific requirement
29 - Guidance and rationale for particular subclauses

Specifies the particular safety requirements for electrocardiographs intended for the production of detachable electrocardiographs for diagnostic purposes. It also applies to vector-cardiographs and equipment for stress testing. This Standard is to be read in conjunction with AS 3200.1.0-1990, and is technically equivalent to IEC 601-2-25:1993.

Committee
HE-003
DocumentType
Standard
ISBN
0 7262 8535 8
Pages
27
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This clause of the General Standard applies except as follows: 1.1* Scope Addition:This Particular International Standard specifies the particular safety requirements for ELECTROCARDIOGRAPHS as defined in 2.102, intended for the production of detachable ELECTROCARDIOGRAMS for diagnostic purposes. It also applies to vector-cardiographs and EQUIPMENT for stress testing.This Particular Standard covers minimum safety requirements.Special requirements concerning use in ambulances, phono-cardiographs, cardiographic monitors, polygraphs, telemetering, special tests (for example, His bundle electrocardiographs), etc. are not covered by this Particular Standard.EQUIPMENT with microelectrodes used directly in the fibres of the heart muscle is also excluded.

Standards Relationship
IEC 60601-2-25:1993 Identical

First published as AS 3201.3-1971.
Second edition 1974.
Revised and redesignated AS 3203-1981.
Jointly revised and redesignated as Joint Standard AS/NZS 3200.2.25:1993.

AS/NZS 2500:1995 Guide to the safe use of electricity in patient care
AS/NZS 60335.2.90:2006 Household and Similar Electrical Appliances - Safety Particular requirements for commercial microwave ovens
AS/NZS 60745.1:2009 Hand-held motor-operated electric tools-Safety General requirements (IEC 60745-1 Ed 4, MOD) (Reconfirmed 2020)
AS 4774.2-2002 Work in compressed air and hyperbaric facilities - Hyperbaric oxygen facilities
AS/NZS 2500:2004 Guide to the safe use of electricity in patient care

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.