• Shopping Cart
    There are no items in your cart

AS/NZS 3823.1.1:2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Performance of electrical appliances - Airconditioners and heat pumps Non-ducted airconditioners and heat pumps - Testing and rating for performance (ISO 5151:2010, MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-05-2012

Superseded date

19-02-2026

Superseded by

AS/NZS ISO 5151:2023

€136.55
Excluding VAT

Adopts ISO1515:2010 to establish test methods for determining the capacity and efficiency ratings of non-ducted, air-cooled airconditioners and non-ducted air-to-air heat pumps. Residential, commercial and industrial single-package and split-system airconditioners and heat pumps are included.

Committee
EL-056
DocumentType
Standard
ISBN
978 1 74342 104 8
Pages
76
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This International Standard specifies the standard conditions for capacity and efficiency ratings of non-ducted air-cooled air conditioners and non-ducted air to air heat pumps. This International Standard is applicable to ducted units rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa.This International Standard also specifies the test methods for determining the capacity and efficiency ratings.Residential, commercial and industrial single-package and split-system air conditioners and heat pumps are included. The equipment (taken to mean non-ducted air conditioners or non-ducted heat pumps, as well as ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa) shall be factory-made, electrically driven and use mechanical compression. This International Standard is applicable to equipment utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller. It isapplicable to equipment utilizing single, multiple and variable capacity components.This International Standard is not applicable to the rating and testing of the following:a) water-source heat pumps or water cooled air conditioners;b) multi-split-system air conditioners and air-to-air heat pumps (see ISO 15042 for the testing of suchequipment);c) mobile (windowless) units having a condenser exhaust duct;d) individual assemblies not constituting a complete refrigeration system;e) equipment using the absorption refrigeration cycle;f) ducted equipment except for those specified in this clause (see ISO 13253 for the testing of suchequipment).This International Standard does not cover the determination of seasonal efficiencies which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

Originated in Australia as AS B210-1966.
Previous and first New Zealand edition AS/NZS 3823.1.1:1998.
Second edition 2012.

AS/NZS 3823.1.2:2012 Performance of electrical appliances - Airconditioners and heat pumps Ducted airconditioners and air-to-air heat pumps - Testing and rating for performance (ISO 13253:2011, MOD)
AS/NZS 3823.2:2013 Performance of electrical appliances - Air conditioners and heat pumps Energy labelling and minimum energy performance standards (MEPS) requirements
AS/NZS 3823.1.4:2012 Performance of electrical appliances - Airconditioners and heat pumps Multiple split-system airconditioners and air-to-air heat pumps - Testing and rating for performance (ISO 15042:2011, MOD)

€136.55
Excluding VAT