• Shopping Cart
    There are no items in your cart

AS/NZS 3823.2:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Performance of household electrical appliances - Room airconditioners - Energy labelling requirements

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-05-2024

Superseded by

AS/NZS 3823.2:2001

Language(s)

English

Published date

01-01-2000

€77.79
Excluding VAT

1 - AS/NZS 3823.2:2000 PERFORMANCE OF HOUSEHOLD ELECTRICAL APPLIANCES-ROOM AIRCONDITIONERS - ENERGY LABELLING REQUIREMENTS
4 - PREFACE
6 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 OBJECTIVE
8 - 1.4 REFERENCED DOCUMENTS
8 - 1.5 DEFINITIONS
8 - 1.5.1 Check test
8 - 1.5.2 Comparative energy consumption (CEC)
8 - 1.5.3 Star Rating Index (SRI)
8 - 1.5.4 Family of models
8 - 1.5.5 Rated capacity
8 - 1.5.6 Rated power
9 - 1.5.7 Star rating
9 - 1.5.8 Statements of intention
9 - 1.6 MEASURED QUANTITIES
9 - 1.7 ROUNDING
10 - SECTION 2 CALCULATIONS FOR THE ENERGY LABEL
10 - 2.1 SCOPE
10 - 2.2 GENERAL
10 - 2.3 NUMBER OF TESTS AND PROCESSING OF DATA
10 - 2.3.1 Number of units required
10 - 2.3.2 Number of tests per unit
10 - 2.3.3 Verification of rated values
10 - 2.4 COMPARATIVE ENERGY CONSUMPTION (CEC)
11 - 2.5 STAR RATING INDEX (SRI)
11 - 2.5.1 General
11 - 2.5.2 SRI cooling
11 - 2.5.3 SRI heating
11 - 2.6 STAR RATING
11 - 2.7 EXAMPLE OF ENERGY EFFICIENCY CALCULATIONS
11 - 2.8 ENERGY LABEL VALIDITY
13 - SECTION 3 PERFORMANCE CRITERION
13 - 3.1 GENERAL
13 - 3.2 MAXIMUM COOLING TEST
14 - SECTION 4 APPLICATION AND TEST RESULT FORMATS
14 - 4.1 APPLICATION FOR REGISTRATION
14 - 4.1.1 General
14 - 4.1.2 Registration
14 - 4.1.3 Test report
14 - 4.1.4 Transitional period
14 - 4.2 HOLDING OF RECORDS
14 - 4.2.1 General
14 - 4.2.2 Data
14 - 4.2.3 Test report
14 - 4.2.4 Availability
15 - SECTION 5 PRINTING AND PLACEMENT OF ENERGY LABELS
15 - 5.1 PLACEMENT
15 - 5.2 MATERIAL AND SHAPE
15 - 5.3 COLOURS
15 - 5.3.1 Cooling only label
15 - 5.3.2 Heating and cooling label
15 - 5.3.3 Heating only label
15 - 5.3.4 Electric heating
16 - 5.4 LABEL REQUIREMENTS
16 - 5.5 SAMPLE LABELS
22 - APPENDIX A - EXAMPLE OF ENERGY EFFICIENCY CALCULATIONS
22 - A1 GENERAL
22 - A2 TEST RESULTS, AVERAGES AND RATED VALUES
22 - TABLE A1
22 - COOLING TEST RESULTS
22 - TABLE A2
22 - HEATING TEST RESULTS
23 - TABLE A3
23 - VERIFICATION OF RATED COOLING SPECIFICATIONS-(PROPORTION OF RATED RESULT)
23 - TABLE A4
23 - VERIFICATION OF RATED HEATING SPECIFICATIONS-(PROPORTION OF RATED RESULT)
23 - A3 CALCULATION OF ENERGY LABEL VALUES
23 - A3.1 Calculation of comparative energy consumption (CEC)
24 - A3. 2 Calculation of Star Rating Index (SRI)
25 - APPENDIX B - FORMAT OF APPLICATION FOR REGISTRATION OF ROOM AIRCONDITIONER FOR ENERGY EFFICIENCY
31 - APPENDIX C - ENERGY LABEL DIMENSIONS
34 - APPENDIX D - CALCULATION OF STAR RATING ACCORDING TO THE PREVIOUS SCALE
34 - D1 SCOPE
34 - D2 DETERMINATION OF STAR RATING
34 - D3 EXAMPLE CALCULATION

Specifies the energy labellingy requirements for non-ducted room airconditioners of the vapour compression type intended for household and similar use, up to a rated cooling capacity of 7.5 kw. It covers only those units with a single refrigeration circuit with one evaporator and one condenser such as unitary systems (window/wall) and single split systems. It does not cover multiple split systems, ducted systems or evaporative coolers. This Standard does not specify electical safety requirements.

Committee
EL-015
DocumentType
Standard
ISBN
0 7337 3305 0
Pages
28
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard specifies the energy labelling requirements for non-ducted room airconditioners of the vapour compression type intended for household and similar use, up to a rated cooling capacity of 7.5 kW. It covers only those units with a single refrigeration circuit with one evaporator and one condenser such as unitary systems (window/wall) and single split systems. It does not cover multi-split systems, ducted systems or evaporative coolers. This Standard does not specify electrical safety requirements.NOTE:The energy labelling of all single phase systems including non-ducted, multi-split and ducted systems is under consideration.This Standard specifies the following values for cooling and heating, as applicable:(a) Rated power.(b) Rated capacity.(c) Energy efficiency ratio (EER) for cooling. (d) Coefficient of performance (COP) for heating. (e) Comparative energy consumption (CEC).(f) Star Rating Index (SRI).(g) Star rating.(h) Some of the requirements for energy label validity.(i) The performance criteria for energy labelling validity.(j) Test report format.(k) Printing requirements for room airconditioner appliance energy labels.

First published AS/NZS 3823.2:1998.
Second edition 2000.

AS/NZS 3823.1.1:1998 Performance of electrical appliances - Airconditioners and heat pumps Non-ducted airconditioners and heat pumps - Testing and rating for performance
AS 2706-1984 Numerical values - Rounding and interpretation of limiting values
AS 1861.1-1988 Air-conditioning units - Methods of assessing and rating performance Refrigerated room air-conditioners

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.