1 - AS/NZS 3823.2:2001 PERFORMANCE OF ELECTRICAL APPLIANCES-AIRCONDITIONERS AND HEAT PUMPS - ENERGY LABELLING AND MINIMUM ENERGY
4 - PREFACE
7 - CONTENTS
8 - SECTION 1 SCOPE AND GENERAL
8 - 1.1 SCOPE
8 - 1.2 APPLICATION
9 - 1.3 OBJECTIVE
9 - 1.4 REFERENCED DOCUMENTS
9 - 1.5 DEFINITIONS
9 - 1.5.1 Check test
9 - 1.5.2 Comparative energy consumption (CEC)
9 - 1.5.3 Star Rating Index (SRI)
10 - 1.5.4 Family of models
10 - 1.5.5 Rated capacity
10 - 1.5.6 Rated power
10 - 1.5.7 Star rating
10 - 1.5.8 Statements of intention
10 - 1.6 MEASURED QUANTITIES
10 - 1.7 ROUNDING
11 - SECTION 2 CALCULATIONS FOR THE ENERGY LABEL
11 - 2.1 SCOPE
11 - 2.2 GENERAL
11 - 2.3 NUMBER OF TESTS AND PROCESSING OF DATA
11 - 2.3.1 Number of units required
11 - 2.3.2 Number of tests per unit
11 - 2.3.3 Verification of rated values
12 - 2.4 COMPARATIVE ENERGY CONSUMPTION (CEC)
12 - 2.5 STAR RATING INDEX (SRI)
12 - 2.5.1 General
12 - 2.5.2 SRI cooling
12 - 2.5.3 SRI heating
12 - 2.6 STAR RATING
13 - 2.7 EXAMPLE OF ENERGY EFFICIENCY CALCULATIONS
13 - 2.8 ENERGY LABEL VALIDITY
14 - SECTION 3 PERFORMANCE CRITERIA
14 - 3.1 GENERAL
14 - 3.2 MAXIMUM COOLING TEST
14 - 3.3 MINIMUM ENERGY PERFORMANCE STANDARD
14 - 3.4 TEST CONDITIONS FOR DETERMINING MINIMUM ENERGY PERFORMANCE STANDARDS OF THREE PHASE APPLIANCES
15 - 3.5 NUMBER OF TESTS AND PROCESSING OF DATA
15 - 3.6 MINIMUM ENERGY PERFORMANCE STANDARD REQUIREMENTS COMPLIANCE
15 - 3.7 CHECK TESTING
16 - SECTION 4 APPLICATION AND TEST RESULT FORMATS
16 - 4.1 APPLICATION FOR REGISTRATION
16 - 4.1.1 General
16 - 4.1.2 Registration
16 - 4.1.3 Test report
16 - 4.2 HOLDING OF RECORDS
16 - 4.2.1 General
16 - 4.2.2 Data
16 - 4.2.3 Test report
18 - SECTION 5 PRINTING AND PLACEMENT OF ENERGY LABELS
18 - 5.1 PLACEMENT
18 - 5.2 MATERIAL AND SHAPE
18 - 5.3 COLOURS
18 - 5.3.1 Cooling only label
18 - 5.3.2 Heating and cooling label
18 - 5.3.3 Heating only label
18 - 5.3.4 Electric heating
19 - 5.4 LABEL REQUIREMENTS
19 - 5.5 SAMPLE LABELS
25 - APPENDIX A - EXAMPLES OF ENERGY EFFICIENCY CALCULATIONS
25 - A1 GENERAL
25 - A2 TEST RESULTS, AVERAGES AND RATED VALUES
26 - A3 CALCULATION OF ENERGY LABEL VALUES
26 - A3.1 Calculation of comparative energy consumption (CEC)
26 - A3.2 Calculation of Star Rating Index (SRI)
27 - A4 MEPS FOR THREE PHASE PACKAGED AIR CONDITIONERS
28 - APPENDIX B - FORMAT OF APPLICATION FOR REGISTRATION OF AN AIRCONDITIONER FOR ENERGY LABELLING
36 - APPENDIX C - FORMAT OF APPLICATION FOR REGISTRATION OF A THREE PHASE PACKAGED AIRCONDITIONER FOR MEPS
44 - APPENDIX D - FORMAT OF SUMMARY TEST RESULTS FOR AN ENERGY LABELLING AND/OR MEPS APPLICATION WHERE FULL TEST REPORTS...
47 - APPENDIX E - ENERGY LABEL DIMENSIONS
50 - AMENDMENT CONTROL SHEET

Specifies the energy labelling requirements for single-phase ducted and non-ducted airconditioners of the vapour compression type intended for household and similar use. The Standard also specifies minimum energy performance standard (MEPS) requirements for three-phase ducted and non-ducted airconditioners of the vapour compression type intended for household, commercial and similar use, up to a rated cooling capacity of 65 kW. It does not cover multi-split systems or evaporative airconditioners. This Standard does not specify electrical safety requirements.

Committee
EL-015
DocumentType
Standard
ISBN
0 7337 3639 4
Pages
35
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies the energy labelling requirements for single-phase ducted and non-ducted airconditioners of the vapour compression type for household use. The Standard also specifies minimum energy performance standard (MEPS) requirements for three-phase ducted and non-ducted airconditioners of the vapour compression type up to a rated cooling capacity of 65 kW and that fall within the scope of AS/NZS 3823.1.1 or AS/NZS 3823.1.2. It does not cover multi-split systems or evaporative airconditioners. This Standard does not specify electrical safety requirements.NOTE: The energy labelling of single phase multi-split systems and the specification of MEPS for three phase multi-split systems is under consideration.This Standard specifies the following values for cooling and heating, as applicable:(a) Rated power.(b) Rated capacity.(c) Energy efficiency ratio (EER) for cooling. (d) Coefficient of performance (COP) for heating. (e) Comparative energy consumption (CEC).(f) Star Rating Index (SRI). (g) Star rating.(h) Some of the requirements for energy label validity.(i) The performance criteria for energy labelling validity.(j) Test report format.(k) Printing requirements for airconditioner appliance energy labels.(l) Minimum energy performance standard requirements.

First published AS/NZS 3823.2:1998.
Second edition 2000.
Third edition 2001.

AS/NZS 3823.1.1:1998 Performance of electrical appliances - Airconditioners and heat pumps Non-ducted airconditioners and heat pumps - Testing and rating for performance
AS 2706-1984 Numerical values - Rounding and interpretation of limiting values

AS/NZS 3823.3:2001 Performance of electrical appliances - Airconditioners and heat pumps - Calculation of performance for minimum energy performance standard (MEPS) requirements
AS/NZS 3823.3:2002 Performance of electrical appliances - Airconditioners and heat pumps Calculation of performance for minimum energy performance standard (MEPS) requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.