AS/NZS 3823.3:2002

Current

Current

The latest, up-to-date edition.

Performance of electrical appliances - Airconditioners and heat pumps Calculation of performance for minimum energy performance standard (MEPS) requirements

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

27-08-2002

€65.33
Excluding VAT

1 - AS/NZS 3823.3:2002 PERFORMANCE OF ELECTRICAL APPLIANCES-AIRCONDITIONERS AND HEAT PUMPS - CALCULATION OF PERFORMANCE FOR MINIM
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 OBJECTIVE
7 - 1.3 APPLICATION
7 - 1.4 REFERENCED DOCUMENTS
7 - 1.5 DEFINITIONS
7 - 1.6 SIMULATION MODEL
7 - 1.6.1 General
7 - 1.6.2 Measurement of appliance operating conditions
7 - 1.6.3 Matching the modelled refrigerant circuit
8 - 1.6.4 Measured data
8 - 1.6.5 Corrections to compressor performance
9 - SECTION 2 MEASUREMENT OF APPLIANCE CHARACTERISTICS
9 - 2.1 SCOPE
9 - 2.2 TEST CONDITIONS
9 - 2.3 MEASUREMENT OF REFRIGERANT CIRCUIT PRESSURE DROP (OPTIONAL)
9 - 2.3.1 General
9 - 2.3.2 Default pressure drop conditions
9 - 2.4 MEASUREMENT OF REFRIGERANT CIRCUIT SET POINT CONDITIONS (OPTIONAL)
9 - 2.4.1 General
9 - 2.4.2 Default refrigerant circuit set point conditions
10 - 2.5 AIRFLOW RATE THROUGH THE COILS
10 - 2.5.1 Non-ducted appliances
10 - 2.5.2 Ducted appliances
10 - 2.6 COMPRESSOR CHARACTERISTICS
10 - 2.7 ELECTRICAL POWER CONSUMPTION
10 - 2.7.1 Power consumption of compressor
10 - 2.7.2 Power consumption of fans
11 - 2.7.3 Power consumption of other electrical components
11 - 2.8 COIL CHARACTERISTICS
12 - SECTION 3 PERFORMANCE ANALYSIS
12 - 3.1 REQUIRED SIMULATION MODEL FEATURES
12 - 3.2 MODEL CHARACTERISTICS
12 - 3.2.1 General
12 - 3.2.2 Correlation models
13 - 3.2.3 Lumped component models
13 - 3.2.4 Simulation models
13 - 3.2.5 Simulation models with specified refrigerant operating states
14 - APPENDIX A - FORMAT SHEETS FOR RECORDING REFRIGERANT CIRCUIT OPERATING CONDITIONS OR ACCEPTANCE OF DEFAULT CONDITIONS
14 - A1 PRESSURE DROP ACROSS HIGH- AND LOW-PRESSURE SIDES OF THE REFRIGERANT CIRCUIT
14 - A1.1 General
14 - A1.2 Test conditions - Cooling
15 - A1.3 Test results - Cooling
15 - A1.4 Test conditions - Heating (if applicable)
15 - A1.5 Test results - Heating (if applicable)
16 - A1.6 Default pressure drop conditions
16 - A2 REFRIGERANT CIRCUIT SET POINT CONDITIONS
16 - A2.1 General
16 - A2.2 Test conditions - Cooling
17 - A2.3 Test results - Cooling
17 - A2.4 Test conditions - Heating (if applicable)
18 - A2.5 Test results - Heating (if applicable)
18 - A2.6 Default refrigerant circuit set point conditions
19 - APPENDIX B - FORMAT SHEETS FOR APPLIANCE DEFINITION
24 - APPENDIX C - THE OAK RIDGE HEAT PUMP MODEL
26 - APPENDIX D - CALCULATION OF HEAT LOSS/GAIN FROM REFRIGERANT LINES

Specifies procedures for calculating the performance of factory-made residential, commercial and industrial, electrically driven, mechanical compression, single-package and split-system, ducted and non-ducted airconditioners for determining their compliance with minimum energy performance standard (MEPS) requirements specified in AS/NZS3823.2.

Committee
EL-015
DocumentType
Standard
ISBN
0 7337 4663 2
Pages
21
ProductNote
Reconfirmed 23/05/2014.This standard has been reconfirmed in Australia in 2014 and remains current in New Zealand. Reconfirmation Notice 23/05/2014
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies procedures for calculating the performance of factory-made residential, commercial and industrial, electrically-driven, mechanical compression, single-package and split-system, ducted and non-ducted airconditioners and heat pumps employing air- and water-cooled condensers. This Standard covers equipment utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units controlled by a single thermostat/controller. This Standard covers equipment utilizing single, multiple and variable capacity components.NOTE: The method in this Standard includes a combination of measured component performance, equipment operating conditions and a mathematical model to determine the appliance performance.This Standard does not cover single circuit multiple compressor units.This Standard can be used to quantify the following values for cooling and heating:(a) Rated cooling capacity.(b) Rated heating capacity.(c) Energy efficiency ratio (EER).(d) Coefficient of performance (COP).This Standard does not apply to the rating of the following:(i) Water-source heat pumps.(ii) Multi-split airconditioners and heat pumps.(iii) Mobile appliances having a condenser exhaust duct.(iv) Unitary systems where there is a thermal interaction between the evaporator and condenser.

Originated as AS/NZS 3823.3:2001.
Second edition 2002.

AS/NZS 3823.1.1:1998 Performance of electrical appliances - Airconditioners and heat pumps Non-ducted airconditioners and heat pumps - Testing and rating for performance
AS/NZS 3823.2:2001 Performance of electrical appliances - Airconditioners and heat pumps Energy labelling and minimum energy performance standard (MEPS) requirements
AS/NZS 3823.1.2:2001 Performance of electrical appliances - Airconditioners and heat pumps Test methods - Ducted airconditioners and air-to-air heat pumps - Testing and rating for performance

AS/NZS 3823.2:2011 Performance of electrical appliances Air conditioners and heat pumps
AS/NZS 3823.2:2013 Performance of electrical appliances - Air conditioners and heat pumps Energy labelling and minimum energy performance standards (MEPS) requirements
AS/NZS 3823.2:2005 Performance of electrical appliances - Airconditioners and heat pumps Energy labelling and minimum energy performance standard (MEPS) requirements
AS/NZS 3823.2:2003 Performance of electrical appliances - Airconditioners and heat pumps Energy labelling and minimum energy performance standard (MEPS) requirements
AS 4755.3.1-2008 Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for airconditioners
AS/NZS 3823.2:2009 Performance of electrical appliances - Air conditioners and heat pumps Energy labelling and minimum energy performance standard (MEPS) requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.