• AS/NZS 4284:2008

    Current The latest, up-to-date edition.

    Testing of building facades

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  28-04-2008

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 4284:2008 TESTING OF BUILDING FACADES
    4 - PREFACE
    6 - CONTENTS
    7 - 1 SCOPE
    7 - 2 REFERENCED DOCUMENTS
    7 - 3 DEFINITIONS
    7 - 3.1 BMU
    7 - 3.2 Framing members
    7 - 3.3 Specifier
    7 - 3.4 Test facility
    8 - 3.5 Uncontrolled water
    8 - 4 NOTATION
    8 - 5 PRINCIPLE
    8 - 6 APPARATUS
    9 - 7 SAMPLE PREPARATION
    9 - 7.1 Test sample
    9 - 7.2 Drawings
    10 - 8 PROCEDURE
    10 - 8.1 Test sequence
    10 - 8.1.1 General
    10 - 8.1.2 Variation of test sequence or retesting
    10 - 8.2 Preliminary tests
    10 - 8.2.1 General
    10 - 8.2.2 Static pressure
    10 - 8.2.3 Water
    10 - 8.3 Structural test at serviceability limit state
    10 - 8.3.1 Structural-test pressures
    11 - 8.3.2 Location of the displacement transducers
    11 - 8.3.3 Pressure loading sequence
    12 - 8.3.4 Displacement measurement of spandrel panels
    13 - 8.3.5 Calculation of deflection/span ratio
    13 - 8.3.6 Calculation of successive member displacement
    13 - 8.3.7 Calculation of maximum displacement
    13 - 8.4 Air infiltration test
    13 - 8.4.1 Test pressure
    14 - 8.4.2 Procedure
    14 - 8.5 Water penetration test by static pressure
    14 - 8.5.1 Test pressure
    14 - 8.5.2 Procedure
    14 - 8.6 Water penetration test by cyclic pressure
    14 - 8.6.1 Test pressure
    15 - 8.6.2 Procedure
    15 - 8.7 BMU restraint test
    15 - 8.7.1 Test load
    15 - 8.7.2 Procedure
    15 - 8.8 Structural test at ultimate limit state
    15 - 8.8.1 Test pressures
    16 - 8.8.2 Procedure
    16 - 8.8.3 Spandrel panel
    16 - 8.9 Seismic test
    16 - 8.9.1 Test displacement
    16 - 8.9.2 Procedure
    16 - 8.10 Seal degradation test
    17 - 9 PERFORMANCE REQUIREMENTS
    17 - 9.1 General
    17 - 9.2 Structural test at serviceability limit state
    17 - 9.2.1 Deflection/span ratios
    17 - 9.2.2 Successive member displacement
    17 - 9.2.3 Maximum displacement
    17 - 9.3 Air infiltration test
    17 - 9.4 Water penetration test
    17 - 9.5 Seismic test at serviceability limit state displacement
    17 - 9.6 BMU restraint test
    18 - 9.7 Structural test at ultimate limit state
    18 - 9.8 Seismic test at ultimate limit state displacement
    18 - 9.9 Seal degradation test
    18 - 10 TEST REPORT
    18 - 10.1 Preliminary test report
    18 - 10.2 Official test report
    20 - APPENDIX A - INFORMATION TO BE SUPPLIED BY SPECIFIER
    23 - APPENDIX B - SAMPLE PREPARATION
    23 - B1 INTRODUCTION
    23 - B2 TEST SAMPLE
    25 - B3 REQUIREMENTS
    26 - B4 INCLINED GLAZING
    27 - APPENDIX C - STRENGTH TEST AT ULTIMATE LIMIT STATE LOADING
    32 - APPENDIX D - AIR INFILTRATION TESTING
    34 - APPENDIX E - WATER PENETRATION TESTING
    36 - APPENDIX F - SEISMIC TESTING

    Abstract - (Show below) - (Hide below)

    Sets out methods of testing building facades for environmental loading including water penetration and air infiltration as well as structural tests. Optional tests include seismic testing, seal degradation and building maintenance unit (BMU) restraint.

    Scope - (Show below) - (Hide below)

    This Standard sets out a method for determining the performance of a representative building facade under simulated conditions of loading. This Standard may be applied to all types of facades including low- and high-rise, commercial, industrial and residential buildings. Tests include displacement of the facade or prototype, water penetration and structural integrity at ultimate limit state as well as optional tests, including BMU restraint, seismic loading and seal degradation. This test method is applicable to prototype testing in a test facility and on-site testing.

    General Product Information - (Show below) - (Hide below)

    Committee BD-080
    Document Type Standard
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as Joint Standard AS/NZS 4284:1995.Second edition 2008. First published as AS/NZS4284:1995. Second edition 2008.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1170.4-2007 Structural design actions Earthquake actions in Australia (Reconfirmed 2018)
    AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
    AS/NZS 1170.0:2002 Structural design actions General principles
    AS 4211.3-1996 Gas recovery or combined recovery and recycling equipment Fluorocarbon refrigerants from commercial/domestic refrigeration and airconditioning systems
    AS 1170.4 SUPP 1-1993 Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads - Commentary (Supplement to AS 1170.4-1993)
    AS/NZS 1170.2:2002 Structural design actions Wind actions
    AS 4211.1-1996 Gas recovery or combined recovery and recycling equipment Fluorocarbon refrigerants from automotive airconditioning systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective