• AS/NZS 4382:1996

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Preparation of function charts for control systems

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  30-06-2017

    Language(s):  English

    Published date:  05-05-1996

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Provides rules and symbols for the preparation of descriptions of the function and behaviour of control systems by establishing an implementation-independent graphical representation. Provides a general process approach to describing control functions and may be applied to non-electrical systems. Method of representation is an industrial application of 'Petri nets'. This Standard is identical with and has been reproduced from IEC 848:1988, including Corrigendum (1990).

    Scope - (Show below) - (Hide below)

    This standard applies to the preparation of descriptions of the function and behaviour of control systems by establishing an implementation-independentgraphical representation. It includes the symbols required as well as rules for their use.This standard has been prepared with a view to electrotechnical applications (especially industrial ones, including electric power generation and distribution), but as it provides a general process orientated way of describing control functions, independent of their technological implementation, no field of application is explicitly excluded. It may also be applied to non-electrIcal systems (for example pneumatic, hydraulic or mechanical) or to parts of systems.The described method of representation should serve as a communication tool between different parties often representing different technological disciplines, involved in the engineering and use of control systems.NOTE - The method of representation described can be considered as an industrial application of "Petri nets" used for the study of the co-ordination of asynchronous events. Compared to "Petri nets", it offers the possibility to start with an overall description of a control system and may, via progressive levels of description, proceed to a description in which all the details of the system are revealed.A mathematical description of the function chart is given in Annex A.

    General Product Information - (Show below) - (Hide below)

    Committee TE-013
    Document Type Standard
    Publisher Standards Australia
    Status Withdrawn
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS/NZS 4382:1996.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1852.351-1978 International electrotechnical vocabulary Automatic control
    AS 2645-1987 Information processing - Documentation symbols and conventions for data, program and system flowcharts, program network charts and systems resources charts

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 4383.1:1996 Preparation of documents used in electrotechnology General requirements
    AS 61850.4-2005 Communication networks and systems in substations - System and project management
    AS IEC 61131.8-2004 Programmable controllers - Guidelines for the application and implementation of programming languages
    AS/NZS 4383.2:1996 Preparation of documents used in electrotechnology Function-oriented diagrams