AS/NZS 4695.2.10:1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire hazard testing of electrotechnical products Test methods - Glow-wire test methods - General
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
05-04-1996
Specifies a glow-wire test to simulate the effect of thermal stresses which may be produced by heat sources such as glowing elements or overloaded resistors, for short periods, in order to assess the fire hazard by a simulation technique. The test described in This Standard is applicable, in the first place, to electrotechnical equipment, its subassemblies and components, but may also be applied to solid electrical insulating materials or other solid combustible materials. This Standard is technically equivalent to and reproduced from IEC 695-2-1/0:1994.
Committee |
EL-002
|
DocumentType |
Standard
|
ISBN |
0 7337 0361 5
|
Pages |
9
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This method of test indicates the relative resistance of solid electrical insulating materials to tracking for voltages up to 600 V when the surface is exposed under electric stress to water with the addition of contaminants.Tracking may occur during this test when voltage is applied between a defined electrode arrangement on the surface of a material and drops of electrolyte are applied between them at defined intervals of time. The number of drops needed to cause failure increases with the reduction of the applied voltage and, below a critical value, tracking ceases to occur.Materials which do not track at the highest test voltage may erode differently. The depth of erosion can be measured. Some materials may ignite during the test.Notes 1. - The grading of materials reached by this method may possibly differ from that obtained by other testing methods for assessing tracking resistance, for example tests based on the use of high voltage, low-current discharges. This test method provides good resolution between materials with relatively poor tracking resistance. It lacks resolution for materials normally required for outdoor use for which the test method in IEC Publication 587: Test Method for Evaluating Resistance to Tracking and Erosion of Electrical Insulating Materials Used under Severe Ambient Conditions, should be used.2 . - The test results as such cannot be used directly for the evaluation of safe creepage distances when designing electrical apparatus.
Standards | Relationship |
IEC 60695-2-1/0:1994 | Identical |
First published in Australia as part of AS 2420-1980.
Second edition 1983.
Third edition 1987.
First published in New Zealand as part of AS 2420-1987.
Jointly revised and redesignated in part as AS/NZS 4695.2.10:1996.
AS/NZS 4695.4:1996 | Fire hazard testing of electrotechnical products Terminology concerning fire tests |
AS/NZS 3100:1997 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 60928:2000 | Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - General and safety requirements (IEC 60928:1995 MOD) |
AS/NZS 61058.1:2008 | Switches for appliances General requirements (IEC 61058-1, Ed. 3.1 (2000), MOD) |
AS/NZS 4695.2.11:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire end-product test and guidance |
AS/NZS 60922:1998 | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements |
AS/NZS 61558.2.6:2001 | Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD) |
AS/NZS 3350.1:2000 | Safety of household and similar electrical appliances General requirements (IEC 60335-1:1994 MOD) |
AS/NZS 61535.1(INT):2001 | Installation couplers General requirements |
AS/NZS 3131:2001 | Approval and test specification - Plugs and socket-outlets for stationary appliances |
AS/NZS 61009.1:1999 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules |
AS/NZS 61058.1:2002 | Switches for appliances General requirements (IEC 61058.1:2000 MOD) |
AS/NZS 3439.2:2002 | Low-voltage switchgear and controlgear assemblies Particular requirements for busbar trunking systems (busways) |
AS/NZS 4695.829:1996 | Fire hazard testing of electrotechnical products Methods of test for the determination of the ignitability of solid electrical insulating materials when exposed to electrically heated wire sources |
AS/NZS 60269.1:2000 | Low-voltage fuses General requirements |
AS/NZS 61046:2001 | Auxiliaries for lamps - D.C. or A.C. supplied electronic step-down convertors for filament lamps - General and safety requirements (IEC 61046:1993, MOD) |
AS/NZS 61558.1:2000 | |
AS/NZS 4695.2.12:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire flammability test on materials |
AS/NZS 4695.2.13:1996 | Fire hazard testing electrotechnical products Test methods - Glow-wire ignitability test on materials |
AS/NZS 3947.1:2001 | Low-voltage switchgear and controlgear General rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.