AS/NZS 4695.2.41:1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire hazard testing of electrotechnical products Test methods - 1 kW nominal premixed test flame and guidance

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS/NZS 60695.11.2:2004

Language(s)

English

Published date

05-05-1996

€32.89
Excluding VAT

1 - AS/NZS 4695.2.41:1996 FIRE HAZARD TESTING OF ELECTROTECHNICAL PRODUCTS - TEST METHODS - 1 kW NOMINAL PREMIXED TEST FLAME AND
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
7 - 1 Scope
7 - 2 Normative references
7 - 3 Definition
8 - 4 Requirements
8 - 5 Production and confirmation of the test flame
8 - 5.1 Production
8 - 5.2 Confirmation
8 - 5.2.1 Principle
8 - 5.2.2 Procedure
9 - 5.2.3 Calculate the mean time in seconds as the result .
9 - 5.2.4 The flame is confirmed and may be used for test purposes if the result is within the range 45 s ± 5 s.
9 - 5.3 Apparatus
9 - 5.3.1 Burner
9 - 5.3.2 Flowmeters
9 - 5.3.3 Manometers
9 - 5.3.4 Control valves
9 - 5.3.5 Copper block
9 - 5.3.6 Thermocouple
10 - 5.3.7 Temperature time indicating/recording and timing devices
10 - 5.3.8 Means of measuring the ambient air temperature and pressure are also required.
10 - 5.3.9 Fuel gas-propane with a purity > 98 %.
10 - 5.3.10 Air-essentially free of oil and water.
10 - 6 Recommended arrangements for use of the test flame
10 - 7 Classification and designation
19 - Annex A - Exampl e of test arrangements
20 - Amendment 1
21 - ANNEX ZA - VARIATIONS BETWEEN THIS STANDARD AND IEC 695-2-4/1:1991

Gives detailed requirements for the production of a 1 kW nominal, propane-based premixed test flame, its approximate overall height being 175 mm. This Standard is technically equivalent to and reproduced from IEC 695-2-4/1:1991.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 0371 2
Pages
13
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This section of IEC 695-2 gives the detailed requirements for the production of the 1 kW nominal, propane based pre-mixed type test flame. The approximate overall flame height is 175 mm.This section should be used in conjunction with IEC 695-2-4/0 and the other guidance publications in IEC 695.

Standards Relationship
IEC 60695-2-4/1:1991 Identical

First published as AS/NZS 4695.2.41:1996.

AS/NZS 4695.2.40:1996 Fire hazard testing of electrotechnical products Test methods - Diffusion type and premixed flame test methods

AS/NZS 4695.2.40:1996 Fire hazard testing of electrotechnical products Test methods - Diffusion type and premixed flame test methods
AS/NZS 2053.5:2001 Conduits and fittings for electrical installations Corrugated conduits and fittings of insulating material (Reconfirmed 2016)
AS/NZS 2053.1:2001 Conduits and fittings for electrical installations General requirements (Reconfirmed 2016)
AS/NZS 2053.6:2001 Conduits and fittings for electrical installations Profile-wall, smooth-bore conduits and fittings of insulating material (Reconfirmed 2016)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.