Excluding VAT

1 - AS/NZS 4805.1:2001 ACCESSORIES FOR ELECTRIC CABLES -TEST REQUIREMENTS - POWER CABLES WITH EXTRUDED INSULATION FOR RATED VOLTA
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.3.1 Bolted-type separable connector
7 - 1.3.2 Branch joint
7 - 1.3.3 Connector
7 - 1.3.4 Deadbreak connector
7 - 1.3.5 Indoor termination
7 - 1.3.6 Loadbreak connector
7 - 1.3.7 Outdoor termination
7 - 1.3.8 Plug-in type separable connector
8 - 1.3.9 Range-taking accessory
8 - 1.3.10 Screened separable connector
8 - 1.3.11 Separable connector
8 - 1.3.12 Shrouded termination
8 - 1.3.13 Straight joint
8 - 1.3.14 Stop-end
8 - 1.3.15 Terminal box
8 - 1.3.16 Termination
8 - 1.3.17 Transition joint
8 - 1.3.18 Unscreened separable connector
8 - 1.4 VOLTAGE DESIGNATIONS AND TEMPERATURE RATING
8 - 1.4.1 Rated voltages
8 - 1.4.2 Rated temperature
9 - SECTION 2 ASSEMBLY OF ACCESSORIES TO BE TESTED
9 - 2.1 IDENTIFICATION
9 - 2.1.1 Cables
9 - 2.1.2 Connectors
9 - 2.1.3 Accessories
9 - 2.2 INSTALLATION AND CONNECTIONS
9 - 2.2.1 Cable conductor size
9 - 2.2.2 Assembly instructions
9 - 2.2.3 Condition of accessories
10 - 2.2.4 Connection of separable connectors
10 - 2.2.5 Lug or bushing sizes
10 - 2.2.6 Unscreened separable connectors
10 - 2.2.7 Branch joints
10 - 2.2.8 Recording
11 - SECTION 3 RANGE OF APPROVAL
11 - 3.1 CONDUCTOR SIZE
11 - 3.1.1 Terminations, joints and stop-ends
11 - 3.1.2 Separable connectors
11 - 3.2 CONDUCTOR MATERIAL
11 - 3.3 FORM OF CONDUCTOR
11 - 3.4 INSULATION MATERIAL
12 - 3.5 INSULATION SCREEN
12 - 3.6 NUMBER OF CORES
13 - SECTION 4 TESTS
13 - 4.1 CATEGORY OF TESTS
13 - 4.2 TEST METHODS
13 - 4.3 TEST ARRANGEMENTS
13 - 4.4 TEST SEQUENCES
13 - 4.5 TEST RESULTS
14 - 4.5.1 Accessory failure
14 - 4.5.2 Cable failure
34 - APPENDIX A - IDENTIFICATION OF TEST CABLE

Specifies the type test requirements on accessories for power cables with extruded insulation and with rated voltages from 1.9/3.3(3.6) kV up to and including 19/33(36) kV, based on IEC 60502-4. Accessories covered are indoor and outdoor terminations, straight joints, branch joints, transition joints and stop-ends, and screened or unscreened plug-in or bolted type separable connectors.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 4032 4
Pages
29
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies the requirements for type testing of accessories for power cables with rated voltages from 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV, complying with AS/NZS 1429.1 or IEC 60502-2.The accessories covered by this Standard are listed below:(a) Indoor and outdoor terminations of all designs, including terminal boxes.(b) Straight joints, branch joints, transition joints and stop-ends of all designs, suitable for use underground or in air.(c) Screened or unscreened plug-in type or bolted-type separable connectors.NOTE: Joints connecting cables with extruded insulation to paper-insulated cables are not included. The requirements for these accessories are dealt with in AS/NZS 4805.2.Accessories for particular cables, such as unscreened aerial, submarine or ship cables, are not included.Approval to this Standard is obtained by carrying out the appropriate tests as specified in Clause 3.1. By agreement with the purchaser, accessories which the manufacturer can demonstrate to have provided satisfactory service experience do not need to be type tested.It is not necessary to repeat these tests, once successfully completed, unless changes are made in the materials, design or manufacturing process which might affect the performance characteristics.Test methods are included in IEC 61442.

First published as AS/NZS 4805.1:2001.

AS/NZS 1429.1:2000 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.