AS/NZS 4865.1:2008

Current

Current

The latest, up-to-date edition.

Performance of commercial ice makers and ice storage bins Test methods for ice makers - Environmental performance (Reconfirmed 2024)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

15-09-2008

€32.89
Excluding VAT

1 - AS/NZS 4865.1:2008 PERFORMANCE OF COMMERCIAL ICE MAKERS AND ICE STORAGE BINS - TEST METHODS FOR ICE MAKERS-ENVIRONMENTAL...
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 NORMATIVE REFERENCES
6 - 3 DEFINITIONS
6 - 3.1 Automatic commercial ice maker
6 - 3.2 Batch-type ice maker
6 - 3.3 Continuous-type ice maker
7 - 3.4 Modular-type ice maker
7 - 3.5 Self-contained ice maker
7 - 3.6 Shall
7 - 3.7 Should
7 - 3.8 Split-system ice maker-Remote condensing and remote compressor
7 - 3.9 Split-system ice maker-Remote condensing but not remote compressor
7 - 3.10 Purge (also blow-down)
7 - 3.11 Capacity
7 - 3.12 Energy consumption rate
7 - 3.13 Ice harvest rate
7 - 3.14 Ice storage bin
7 - 3.15 Potable water use rate
7 - 3.16 Condenser water use rate
7 - 3.17 Separate storage compartment
7 - 3.18 Standard rating
8 - 3.19 Standard rating conditions
8 - 4 GENERAL CONDITIONS FOR MEASUREMENT
8 - 4.1 General
8 - 4.2 Test room
8 - 4.2.1 Air movement
8 - 4.2.2 Air temperature and relative humidity
8 - 4.2.3 Radiation
8 - 4.3 Water supply
8 - 4.4 Location of unit in test room
8 - 4.5 Power supply
9 - 5 EQUIPMENT AND SET-UP
9 - 5.1 Set-up
9 - 6 ACCURACY OF MEASUREMENT AND INSTRUMENTATION
9 - 6.1 Temperature
9 - 6.2 Electrical energy consumption
9 - 6.3 Time
10 - 6.4 Mass of ice
10 - 7 TEST PROCEDURE
10 - 7.1 Simultaneous tests
10 - 7.2 Stabilization
10 - 7.3 Ice sampling
10 - 7.3.1 Cube ice
10 - 7.3.2 Non-cube ice
10 - 7.4 Recording
10 - 7.5 Capacity test
11 - 7.6 Water consumption test
11 - 7.7 Energy consumption test
11 - 8 CALCULATIONS
11 - 8.1 Capacity of ice-maker
11 - 8.2 Water used in condenser
11 - 8.3 Potable water used in ice-making
11 - 8.4 Daily energy consumption
12 - 9 REPORTING

Specifies methods of measuring the electrical power consumption of water- and air-cooled commercial ice makers connected to a nominal 230V mains electricity supply.

Committee
ME-008
DocumentType
Standard
ISBN
0 7337 8878 5
Pages
7
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies methods of measuring the electrical power consumption of water- and air-cooled commercial ice makers connected to a nominal 230 V mains electricity supply.This Standard applies to batch-type and continuous ice makers that produce ice in irregular shapes, flakes, ribbons or wafers as well as uniformly shaped ice cubes where the finished product does not exceed approximately 100 g in weight.This Standard-(a) specifies methods and procedures for measuring ice-making capacity;(b) specifies methods and procedures for measuring the energy consumption of ice makers; and(c) specifies methods and procedures for measuring the water consumption of ice makers.This Standard does not apply to ice-making devices intended to be incorporated in household appliances.

First published as AS/NZS 4865.1:2008.

AS 2706-2003 Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018)

AS/NZS 4865.3:2008 Performance of commercial ice makers and ice storage bins Minimum energy performance standard (MEPS) requirements (Reconfirmed 2024)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.