• Shopping Cart
    There are no items in your cart

AS/NZS 4965.1:2008

Current

Current

The latest, up-to-date edition.

Performance of close control airconditioners Testing for rating (Reconfirmed 2020)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

14-11-2008

€77.79
Excluding VAT

1 - AS/NZS 4965.1:2008 PERFORMANCE OF CLOSE CONTROL AIRCONDITIONERS - TESTING FOR RATING
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 APPLICATION
6 - 3 REFERENCED DOCUMENTS
6 - 4 DEFINITIONS
7 - 4.1 Close control airconditioner
7 - 4.2 Cooling energy efficiency ratio (EER)
7 - 4.3 Effective power input (PE)
7 - 4.4 Full load operation
7 - 4.5 Gross sensible cooling capacity
7 - 4.6 Gross total cooling capacity
7 - 4.7 Indoor discharge airflow
7 - 4.8 Indoor intake airflow
7 - 4.9 Latent capacity-Room dehumidifying capacity
7 - 4.10 Net sensible cooling capacity
7 - 4.11 Net total cooling capacity
7 - 4.12 Outdoor discharge airflow
7 - 4.13 Outdoor intake airflow
7 - 4.14 Rated frequency(ies)
8 - 4.15 Rated voltage(s)
8 - 4.16 Sensible energy efficiency ratio (EERS)
8 - 4.17 Sensible heat ratio
8 - 4.18 Shall
8 - 4.19 Should
8 - 4.20 Standard air
8 - 5 COOLING TESTS
8 - 5.1 Cooling capacity ratings
8 - 5.1.1 General conditions
8 - 5.1.2 Temperature conditions
8 - 5.1.3 Airflow conditions
9 - 5.1.4 Test conditions
9 - 6 TEST METHODS AND UNCERTAINTY OF MEASUREMENT
9 - 6.1 Test methods
10 - 6.2 Uncertainty of measurement
10 - 6.3 Variations in individual readings
10 - 6.4 Test tolerances
11 - 6.5 Standby power and crankcase heaters
11 - 6.5.1 General
11 - 6.5.2 Off mode
12 - 6.5.3 Passive standby mode
12 - 6.5.4 Delay start mode
12 - 6.5.5 Crankcase heaters
12 - 6.6 Testing airconditioners with variable output compressors
13 - 7 TEST RESULTS
13 - 7.1 Capacity calculations
13 - 7.1.1 General
13 - 7.1.2 Adjustments
13 - 7.2 Data to be recorded
14 - 7.3 Test report
14 - 7.3.1 General information
14 - 7.3.2 Additional information
14 - 7.3.3 Rating test results
16 - 8 PUBLICATION OF RATINGS
16 - 8.1 Standard ratings
16 - 8.2 Other ratings
17 - APPENDIX A - TEST PROCEDURES
17 - A1 GENERAL TEST ROOM REQUIREMENTS
17 - A2 EQUIPMENT INSTALLATION
17 - A3 ELECTRICAL SUPPLY REQUIREMENTS
18 - APPENDIX B - CALORIMETER TEST METHOD
18 - B1 GENERAL
23 - B2 CALIBRATED ROOM-TYPE CALORIMETER
24 - B3 BALANCED AMBIENT ROOM-TYPE CALORIMETER
25 - B4 CALORIMETER AND AUXILIARY EQUIPMENT FOR WATER-COOLED CONDENSER TESTS
26 - APPENDIX C - HEATING AND COOLING CAPACITY CALCULATIONS
26 - C1 COOLING CAPACITY CALCULATIONS (CALORIMETER METHOD)
28 - C2 COOLING CAPACITY CALCULATIONS (AIR-ENTHALPY METHOD)
30 - APPENDIX D - AIRFLOW MEASUREMENT
30 - D1 AIRFLOW DETERMINATION
30 - D2 NOZZLES
31 - D3 APPARATUS FOR ROOM DISCHARGE AIRFLOW MEASUREMENTS
32 - D4 INDOOR-SIDE DISCHARGE AIRFLOW MEASUREMENT
33 - D5 VENTILATION, EXHAUST AND LEAKAGE AIRFLOW MEASUREMENTS
33 - D6 TEST APPARATUS CALIBRATION (AIR-ENTHALPY METHOD)
34 - APPENDIX E - REFRIGERANT ENTHALPY TEST METHOD
34 - E1 GENERAL DESCRIPTION
34 - E2 REFRIGERANT FLOW METHOD
34 - E3 REFRIGERANT TEMPERATURE AND PRESSURE MEASUREMENTS
35 - E4 CALCULATION COOLING CAPACITIES
36 - APPENDIX F - LIST OF SYMBOLS

Specifies the conditions on which the capacity and energy consumption of factory-made close control airconditioners are based and the test methods to be applied for determining the capacity and efficiency ratings.

Committee
EL-015
DocumentType
Standard
ISBN
0 7337 8938 2
Pages
32
ProductNote
Reconfirmed 18/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 18/09/2020
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies the conditions on which the capacity and energy consumption of factory-made close control airconditioners are based and the test methods to be applied to determine the capacity and efficiency ratings. This Standard covers equipment utilizing a single or multiple refrigerated direct expansion (DX) system designed to control and monitor temperature and humidity and may include supplementary conditioning equipment.Appendix A establishes testing procedures. Appendix B describes the test facilities required for the calorimeter method. Appendix C provides formulae for calculating heating and cooling capacities. Appendix D describes methods for measuring airflow. Appendix E describes the refrigerant enthalpy test method. Appendix F lists the symbols used in this Standard.This Standard does not cover the determination of seasonal efficiencies, which may be required in some countries.

First published as AS/NZS 4965.1:2008.

AS/NZS 62301:2005 Household electrical appliances - Measurement of standby power (IEC 62301, Ed. 1.0 (2005) MOD)

AS/NZS 3823.2:2013 Performance of electrical appliances - Air conditioners and heat pumps Energy labelling and minimum energy performance standards (MEPS) requirements
AS/NZS 4965.2:2008 Performance of close control airconditioners Minimum energy performance standard (MEPS) requirements (Reconfirmed 2020)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.