1 - AS/NZS 4965.1:2008 PERFORMANCE OF CLOSE CONTROL AIRCONDITIONERS - TESTING FOR RATING
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 APPLICATION
6 - 3 REFERENCED DOCUMENTS
6 - 4 DEFINITIONS
7 - 4.1 Close control airconditioner
7 - 4.2 Cooling energy efficiency ratio (EER)
7 - 4.3 Effective power input (PE)
7 - 4.4 Full load operation
7 - 4.5 Gross sensible cooling capacity
7 - 4.6 Gross total cooling capacity
7 - 4.7 Indoor discharge airflow
7 - 4.8 Indoor intake airflow
7 - 4.9 Latent capacity-Room dehumidifying capacity
7 - 4.10 Net sensible cooling capacity
7 - 4.11 Net total cooling capacity
7 - 4.12 Outdoor discharge airflow
7 - 4.13 Outdoor intake airflow
7 - 4.14 Rated frequency(ies)
8 - 4.15 Rated voltage(s)
8 - 4.16 Sensible energy efficiency ratio (EERS)
8 - 4.17 Sensible heat ratio
8 - 4.18 Shall
8 - 4.19 Should
8 - 4.20 Standard air
8 - 5 COOLING TESTS
8 - 5.1 Cooling capacity ratings
8 - 5.1.1 General conditions
8 - 5.1.2 Temperature conditions
8 - 5.1.3 Airflow conditions
9 - 5.1.4 Test conditions
9 - 6 TEST METHODS AND UNCERTAINTY OF MEASUREMENT
9 - 6.1 Test methods
10 - 6.2 Uncertainty of measurement
10 - 6.3 Variations in individual readings
10 - 6.4 Test tolerances
11 - 6.5 Standby power and crankcase heaters
11 - 6.5.1 General
11 - 6.5.2 Off mode
12 - 6.5.3 Passive standby mode
12 - 6.5.4 Delay start mode
12 - 6.5.5 Crankcase heaters
12 - 6.6 Testing airconditioners with variable output compressors
13 - 7 TEST RESULTS
13 - 7.1 Capacity calculations
13 - 7.1.1 General
13 - 7.1.2 Adjustments
13 - 7.2 Data to be recorded
14 - 7.3 Test report
14 - 7.3.1 General information
14 - 7.3.2 Additional information
14 - 7.3.3 Rating test results
16 - 8 PUBLICATION OF RATINGS
16 - 8.1 Standard ratings
16 - 8.2 Other ratings
17 - APPENDIX A - TEST PROCEDURES
17 - A1 GENERAL TEST ROOM REQUIREMENTS
17 - A2 EQUIPMENT INSTALLATION
17 - A3 ELECTRICAL SUPPLY REQUIREMENTS
18 - APPENDIX B - CALORIMETER TEST METHOD
18 - B1 GENERAL
23 - B2 CALIBRATED ROOM-TYPE CALORIMETER
24 - B3 BALANCED AMBIENT ROOM-TYPE CALORIMETER
25 - B4 CALORIMETER AND AUXILIARY EQUIPMENT FOR WATER-COOLED CONDENSER TESTS
26 - APPENDIX C - HEATING AND COOLING CAPACITY CALCULATIONS
26 - C1 COOLING CAPACITY CALCULATIONS (CALORIMETER METHOD)
28 - C2 COOLING CAPACITY CALCULATIONS (AIR-ENTHALPY METHOD)
30 - APPENDIX D - AIRFLOW MEASUREMENT
30 - D1 AIRFLOW DETERMINATION
30 - D2 NOZZLES
31 - D3 APPARATUS FOR ROOM DISCHARGE AIRFLOW MEASUREMENTS
32 - D4 INDOOR-SIDE DISCHARGE AIRFLOW MEASUREMENT
33 - D5 VENTILATION, EXHAUST AND LEAKAGE AIRFLOW MEASUREMENTS
33 - D6 TEST APPARATUS CALIBRATION (AIR-ENTHALPY METHOD)
34 - APPENDIX E - REFRIGERANT ENTHALPY TEST METHOD
34 - E1 GENERAL DESCRIPTION
34 - E2 REFRIGERANT FLOW METHOD
34 - E3 REFRIGERANT TEMPERATURE AND PRESSURE MEASUREMENTS
35 - E4 CALCULATION COOLING CAPACITIES
36 - APPENDIX F - LIST OF SYMBOLS