• AS/NZS 5000.1:2003

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  28-11-2003

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 5000.1:2003 ELECTRIC CABLES-POLYMERIC INSULATED - FOR WORKING VOLTAGES UP TO AND INCLUDING 0.6/1 (1.2) KV
    4 - PREFACE
    5 - CONTENTS
    6 - 1 SCOPE
    6 - 2 REFERENCED DOCUMENTS
    7 - 3 DEFINITIONS
    7 - 3.1 Aerial cables
    7 - 3.2 Approximate value
    7 - 3.3 Core (of a cable)
    7 - 3.4 Direction of lay
    7 - 3.5 Fictitious values
    7 - 3.6 Fixed cable
    7 - 3.7 Flexible cable
    7 - 3.8 Multicore cable
    7 - 3.9 Non-hygroscopic material
    7 - 3.10 Pitch circle diameter
    7 - 3.11 Routine tests
    7 - 3.12 Sample tests
    8 - 3.13 Shall
    8 - 3.14 Should
    8 - 3.15 Type tests
    8 - 3.16 Voltage designation
    8 - 3.17 Wavelength or length of lay
    8 - 4 VOLTAGE DESIGNATION
    8 - 5 CONDUCTORS
    9 - 6 INSULATION
    9 - 6.1 Material
    9 - 6.1.1 General
    9 - 6.1.2 Aerial cables or fixed cables used in outdoor applications
    9 - 6.2 Application
    9 - 6.3 Thickness
    10 - 6.4 Core identification
    10 - 6.4.1 Restricted colours
    10 - 6.4.2 Method
    11 - 6.4.3 Colours
    11 - 6.4.4 Figures and words
    11 - 7 ASSEMBLY OF CORES
    11 - 7.1 Flat cables
    11 - 7.2 Circular cables
    11 - 7.2.1 Lay-up of cores
    11 - 7.2.2 Fillers, barrier tapes and binders
    12 - 8 BEDDING (OPTIONAL)
    12 - 8.1 General
    12 - 8.2 Material
    12 - 8.3 Application
    12 - 8.3.1 Taped bedding
    12 - 8.3.2 Extruded bedding
    12 - 8.4 Thickness
    12 - 8.4.1 General
    12 - 8.4.2 Reduced thickness taped bedding under a metallic screen or concentric conductor
    13 - 9 METALLIC LAYERS (OPTIONAL)
    13 - 10 SEPARATION LAYER (OPTIONAL)
    13 - 10.1 General
    13 - 10.2 Material and application
    13 - 10.3 Thickness
    14 - 11 ARMOUR (OPTIONAL)
    14 - 11.1 Material
    14 - 11.2 Dimensions of wire and tape
    14 - 11.3 Application
    14 - 11.3.1 General
    14 - 11.3.2 Wire armour
    15 - 11.3.3 Tape armour
    15 - 11.4 Further protection
    15 - 12 METALLIC SHEATH (OPTIONAL)
    15 - 12.1 Material
    15 - 12.2 Application
    15 - 12.3 Thickness
    15 - 12.4 Further protection
    15 - 13 NON-METALLIC SHEATH (OPTIONAL)
    15 - 13.1 General
    16 - 13.2 Material
    16 - 13.3 Application
    16 - 13.4 Thickness
    16 - 13.4.1 Average thickness
    17 - 13.4.2 Minimum thickness
    17 - 13.4.3 Thickness of combined layer
    17 - 14 NON-METALLIC BRAID (OPTIONAL)
    17 - 14.1 Material and application
    18 - 14.2 Thickness
    18 - 15 FURTHER PROTECTION (OPTIONAL)
    18 - 16 MARKING
    18 - 16.1 Information to be marked
    18 - 16.2 Means of marking
    19 - 16.3 Marking of packaging
    19 - 17 TESTS
    22 - APPENDIX A - PURCHASING GUIDELINES
    22 - A1 GENERAL
    22 - A2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
    23 - APPENDIX B - THE FICTITIOUS CALCULATION METHOD FOR THE DETERMINATION OF THE DIMENSIONS OF PROTECTIVE COVERINGS
    23 - B1 INTRODUCTION
    23 - B2 GENERAL
    23 - B3 METHOD
    23 - B3.1 Conductors
    24 - B3.2 Cores
    24 - B3.3 Diameter over laid-up cores
    26 - B3.4 Bedding
    27 - B3.5 Metallic screen or concentric conductor
    27 - B3.6 Metallic sheath
    27 - B3.7 Separation layer
    27 - B3.8 Armour
    28 - B3.9 Non-metallic sheath

    Abstract - (Show below) - (Hide below)

    Specifies the construction, dimensions and test requirements for cables insulated with polymeric materials intended for use in electrical installations at working voltages up to and including 0.6/1 (1.2) kV. It does not apply to polymeric insulated cables for special installations for which there are separate Australian/New Zealand Standards, e.g. flexible lift control cables, neutral screened cables, welding cables, flexible cords and aerial bundled cables.

    Scope - (Show below) - (Hide below)

    This Standard specifies construction, dimensions and tests for single and multicore cables insulated with polymeric materials intended for use in electrical installations at working voltages up to and including 0.6/1 (1.2) kV. It does not apply to polymeric insulated cables for special installations and service conditions or for which there are separate Australian/New Zealand Standards, e.g. flexible lift control cables, neutral screened cables, welding cables, flexible cords and aerial bundled cables. NOTES: 1 Purchasing guidelines are contained in Appendix A. 2 AS/NZS 3008.1 should be referenced to assist correct cable size selection for the intended application and installation.

    General Product Information - (Show below) - (Hide below)

    Committee EL-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published in Australia as part of AS C50-1928.Second edition 1939 (being endorsement of BS 7-1939 with amendments).AS C116 first published 1941.AS C130 first published 1941.AS (E)C502 first published 1943.AS C50-1939, AS C116-1941, AS C130-1941 and AS (E)C502-1943 revised, amalgamated and designated AS C116-1950.AS C147 first published 1950.Third edition AS C116-1955.Second edition AS C147-1955.AS C178 first published 1966.Fourth edition AS C116-1967.Third edition AS C147-1967.Fourth edition 1969.Fourth edition AS C116-1970.AS C189 first published 1971.Fifth edition AS C147-1972.Sixth edition AS C116-1972.Revised and redesignated in part as AS 3116-1974.AS C189-1971 and part of AS C147-1972 revised, amalgamated and redesignated AS 3147-1974.AS C178-1966 revised and redesignated in part as AS 3178-1975.AS C189-1971 withdrawn 1976.AS C147-1972 withdrawn 1976.Second edition AS 3147-1976.Second edition AS 3116-1976.AS 3198 first published 1977.Second edition AS 3178-1978.Third edition AS 3116-1981.Third edition AS 3147-1981.Fourth edition 1988.Fourth edition AS 3116-1990.Second edition AS 3198-1990.Third edition AS 3178-1991.Fifth edition AS 3147-1992.First published in New Zealand as NZS/AS 3198-1990.NZS/AS 3116 first published 1990. NZS/AS 3198-1990 jointly revised and designated as AS/NZS 3198:1996.NZS/AS 3116-1990 jointly revised and designated as AS/NZS 3116:1996.AS 3147-1992, AS/NZS 3116:1996 and AS/NZS 3198:1996 jointly revised, amalgamated and redesignated AS/NZS 5000.1:1999.AS 3178-1991 and AS/NZS 5000.1:1999 jointly revised, amalgamated and redesignated AS/NZS 5000.1:2003. First published in Australia in part as AS 4802.3-1991. AS 4802.3 Supplement 1 first published 1991. AS 4802.3 Supplement 2 first published 1992. First published in New Zealand as NZS/ISO/IEC 8802-3:1990. AS 4802.3-1991, AS 4802.3 Supplement 1-1991, AS 4802.3 Supplement 2-1992 and NZS/ISO/IEC 8802-3:1990, jointly revised, amalgamated and designated as Joint Standard AS/NZS 4802.3:1994.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
    AS/NZS 1660.2.2:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to elastomeric, XLPE and XLPVC materials (Reconfirmed 2017)
    AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
    AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
    AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors
    AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
    AS/NZS 1660.2.3:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to PVC and halogen free thermoplastic materials (Reconfirmed 2017)
    AS/NZS 4507:1998 Cables - Fire performance
    AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
    AS/NZS 1660.3:1998 Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017)
    AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
    AS/NZS 2893:2002 Electric cables - Lead and lead alloy sheaths - Composition
    AS/NZS 1660.1:1998 Test methods for electric cables, cords and conductors Conductors and metallic components (Reconfirmed 2017)
    AS/NZS 3863:2002 Galvanized mild steel wire for armouring of cables
    AS 2706-1984 Numerical values - Rounding and interpretation of limiting values
    AS/NZS 1660.5.6:1998 Test methods for electric cables, cords and conductors Fire tests - Test for combustion propagation
    AS/NZS 1660.2.1:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application (Reconfirmed 2017)

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3015:2004 Electrical installations - Extra-low voltage d.c. power supplies and service earthing within public telecommunications networks
    AS 2402.1.1-2005 Traction batteries - Lead-acid Vented cells - Requirements (Reconfirmed 2021)
    AS 2832.1-2004 Cathodic protection of metals Pipes and cables
    AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
    AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
    AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance - General requirements
    AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
    AS/NZS 1768(INT):2003 Lightning protection
    AS 2402.2.1-2005 Traction batteries - Lead-acid Valve-regulated cells - Requirements (Reconfirmed 2021)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective