• AS/NZS 60265.1:2001

    Current The latest, up-to-date edition.

    High-voltage switches Switches for rated voltages above 1 kV and less than 52 kV (IEC 60265-1:1998, MOD) (Reconfirmed 2016)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  17-10-2001

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Applies to three-phase a.c. switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from 16 2/3 Hz up to and including 60 Hz. Is also applicable to the operating devices of these switches and to their auxiliary equipment. It is intended to be read in conjunction with AS/NZS 2650. This Standard is technically equivalent to and contains the full content of IEC 60265:1998 and its Corrigendum:2000.

    Scope - (Show below) - (Hide below)

    This Part of IEC 60265 is applicable to three-phase, alternating current switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from16 2/3 Hz up to and including 60 Hz.This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.Switch-disconnectors are also covered by IEC 60129.General principles and provisions of this standard may also be applicable to single pole switches intended for application in single-phase systems. The requirements for dielectric tests and making and breaking tests should be in accordance with the requirements of the specific application.NOTE 1 –Except where special clarification is required, the term “switch” is used to refer to all kinds of switches and switch-disconnectors within the scope of this standard.NOTE 2 –Earthing switches are not covered by this standard. Earthing switches forming an integral Part of a switch are covered by IEC 60129.NOTE 3 –This standard is not applicable to switching devices attached as an accessory to a high-voltage fuse assembly or its mounting and operated by opening and closing the fuse assembly.

    General Product Information - (Show below) - (Hide below)

    Committee EL-007
    Document Type Standard
    Product Note Reconfirmed 29/07/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 29/07/2016
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS C339-1967.Revised and redesignated as AS 1025-1971.Second edition 1979.Revised and redesignated as AS 1025.1-1984.Jointly revised and redesignated AS/NZS 60265.1:2001.Reconfirmed 2016. First published as AS C339-1967. Revised and redesignated as AS 1025-1971. Second edition 1979. Revised and redesignated as AS 1025.1-1984. Jointly revised and redesignated AS/NZS 60265.1:2001.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 2024-1991 High voltage a.c. switchgear and controlgear - Switch-fuse combinations
    AS 4372-1996 High-voltage alternating current circuit-breakers - Inductive load switching
    AS 1306-1985 High voltage a.c. switchgear and controlgear - Disconnectors (isolators) and earthing switches
    AS 2006-1986 High voltage a.c. switchgear and controlgear - Circuit breakers for rated voltages above 1000 V
    AS 1824.1-1995 Insulation co-ordination Definitions, principles and rules
    AS/NZS 2650:2000 Common specifications for high-voltage switchgear and controlgear standards

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 62271.200-2005 High-voltage switchgear and controlgear A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-200, Ed. 1 (2003) MOD)
    AS 62271.102-2005 High voltage switchgear and controlgear Alternating current disconnectors and earthing switches (IEC 62271-102, Ed.1.0(2003) MOD)
    AS 62271.201-2008 High-voltage switchgear and controlgear AC insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective