• There are no items in your cart

AS/NZS 60695.11.4:2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire hazard testing Test flames - 50 W flames - Apparatus and confirmational test methods (IEC 60695-11-4:2000, IDT)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Language(s)

English

Published date

01-01-2001

1 - AS/NZS 60695.11.4:2001 FIRE HAZARD TESTING - TEST FLAMES-50 W FLAMES-APPARATUS AND CONFIRMATIONAL TEST METHODS
4 - CONTENTS
7 - PREFACE
8 - INTRODUCTION
9 - 1 Scope
9 - 2 Normative references
10 - 3 Definition
10 - 3.1 standardized 50 W nominal test flame
10 - 4 Method A
10 - 4.1 Requirements
11 - 4.2 Apparatus and fuel
11 - 4.2.1 Burner
11 - 4.2.2 Flowmeter
11 - 4.2.3 Manometer
11 - 4.2.4 Control valve
11 - 4.2.5 Copper block
11 - 4.2.6 Thermocouple
11 - 4.2.7 Temperature/time indicating/recording devices
11 - 4.2.8
12 - 4.2.9
12 - 4.2.10 Laboratory fumehood/chamber
12 - 4.3 Production of test flame
12 - 4.4 Confirmation of the test flame
12 - 4.4.1 Principle
12 - 4.4.2 Procedure
13 - 4.4.3 Verification
13 - 5 Method B
13 - 5.1 Requirements
14 - 5.2 Apparatus and fuel
14 - 5.2.1 Burner
14 - 5.2.2 Flowmeters
14 - 5.2.3 Manometer
14 - 5.2.4 Control valves
14 - 5.2.5 Copper block
14 - 5.2.6 Thermocouple
15 - 5.2.7 Temperature/time indicating/recording devices
15 - 5.2.8
15 - 5.2.9
15 - 5.2.10
15 - 5.2.11 Laboratory fumehood/chamber
15 - 5.3 Production of test flame
15 - 5.4 Confirmation of the test flame
15 - 5.4.1 Principle
15 - 5.4.2 Procedure
16 - 5.4.3 Verification
16 - 6 Method C
16 - 6.1 Requirements
17 - 6.2 Apparatus and fuel
17 - 6.2.1 Burner
17 - 6.2.2 Flowmeters
17 - 6.2.3 Manometers
17 - 6.2.4 Control valves
17 - 6.2.5 Copper block
18 - 6.2.6 Thermocouple
18 - 6.2.7 Temperature/time indicating/recording devices
18 - 6.2.8
18 - 6.2.9
18 - 6.2.10
18 - 6.2.11 Laboratory fumehood/chamber
18 - 6.3 Production of test flame
19 - 6.4 Confirmation of the test flame
19 - 6.4.1 Principle
19 - 6.4.2 Procedure
19 - 6.4.3 Verification
19 - 7 Classification and designation
22 - Annex A - Test arrangements according to method A
26 - Annex B - Test arrangements according to method B
32 - Annex C - Test arrangements according to method C
41 - Annex D - Recommended arrangements for the use of the test flame
42 - Annex E - Clearance gauge
43 - Annex F - Examples of test arrangements for tests on equipment
44 - Annex G - Examples of test arrangements for tests on bar specimens
45 - Bibliography

This technical specification provides detailed requirements for the production of a 50 W nominal, pre-mixed type test flame, with an overall height of approximately 20 mm. Identical to and reproduced from IEC 60695-11-4:2000.

This technical specification provides detailed requirements for the production of a 50 W nominal, pre-mixed type test flame, with an overall height of approximately 20 mm.Three methods, A, B and C, are given: flame A is produced by methane; flames B and C are capable of being produced with either methane or propane.One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 4419 2
Pages
37
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC TS 60695-11-4:2000 Identical

First published as AS/NZS 60695.1.1:2001.

View more information
€84.63
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.