• AS/NZS 61000.3.2:1998

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electromagnetic compatibility (EMC) Limits - Limits for harmonic current emissions (equipment input current less than or equal to 16 A per phase)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  05-05-1998

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 61000.3.2:1998 ELECTROMAGNETIC COMPATIBILITY (EMC) - LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURR
    4 - PREFACE
    6 - CONTENTS
    9 - 1 Scope
    9 - 2 Normative references
    10 - 3 Definitions
    10 - 3.1 portable tool:
    10 - 3.2 lamp:
    10 - 3.3 self-ballasted lamp:
    10 - 3.4 luminaire:
    10 - 3.5 semi-luminaire:
    10 - 3.6 ballast:
    10 - 3.7 step-down converter for lighting equipment:
    11 - 3.8 lighting unit:
    11 - 3.9 reference lamp:
    11 - 3.10 reference ballast:
    11 - 3.11 input current:
    11 - 3.12 circuit power factor:
    11 - 3.13 active power:
    11 - 3.14 balanced three-phase equipment:
    11 - 3.15 professional equipment:
    11 - 4 General
    11 - 5 Classification of equipment
    14 - 6 General requirements
    14 - 6.1 Control methods
    14 - 6.2 Harmonic current measurement
    14 - 6.2.1 Steady state
    15 - 6.2.2 Transitory state
    15 - 6.3 Equipment in a rack or case
    15 - 7 Harmonic current limits
    15 - 7.1 Limits for Class A equipment
    15 - 7.2 Limits for Class B equipment
    15 - 7.3 Limits for Class C equipment
    15 - 7.3.1 Lighting equipment
    15 - 7.3.2 Dimming devices
    16 - 7.4 Limits for Class D equipment
    18 - Annex A - Measurement circuit and supply source
    18 - A.1 Test circuit
    18 - A.2 Supply source
    21 - Annex B - Requirements for measurement equipment
    21 - B.1 General
    21 - B.2 Requirements common to all instrumentation
    21 - B.3 Requirements for frequency-domain instrumentation
    22 - B.4 Requirements for time-domain instrumentation using Discrete-Fourier-Transform (DFT)
    23 - B.5 Requirements for time-domain instrumentation using a system other than DFT (for example, digital filtering)
    24 - Annex C - Type test conditions
    24 - C.1 General test conditions
    24 - C.2 Test conditions for television (TV) receivers
    25 - C.3 Test conditions for audio amplifiers
    25 - C.4 Test conditions for video-cassette recorders
    25 - C.5Test conditions for lighting equipment
    26 - C.6 Test conditions for independent and built-in incandescent lamp dimmers
    26 - C.7 Test conditions for vacuum cleaners
    26 - C.8 Test conditions for washing machines
    27 - C.9 Test conditions for microwave ovens
    27 - C.10 Test conditions for information technology equipment (ITE)
    27 - C.11 Test conditions for induction hobs
    27 - C.12 Test conditions for other equipment
    28 - APPENDIX ZZ - VARIATIONS TO IEC 61000-3-2:1995 FOR APPLICATION IN AUSTRALIA AND NEW ZEALAND

    Abstract - (Show below) - (Hide below)

    Specifies the harmonic requirements for equipment with a current input less than or equal to 16 A intended for connection to an electrical network. This Standard is technically equivalent to and has been reproduced from IEC 61000-3-2:1995.

    Scope - (Show below) - (Hide below)

    This Standard specifies the energy labelling requirements for non-ducted room airconditioners of the vapour compression typeintended for household and similar use up to a rated cooling capacity of 7.5 kW. It covers only those units with a single refrigeration circuit with one evaporator and one condenser such as unitary systems(window/wall) and single split systems. It does not cover multiple split systems, ducted systems or evaporative coolers. This Standard does not specify electrical safety requirements. This Standard specifies the following values for cooling,and where applicable, heating: (a) Rated power.(b) Rated capacity.(c) Energy efficiency ratio (EER).(d) Coefficient of performance (COP).(e) Comparative energy consumption (CEC) for 500 hours.(f) Energy efficiency value (EEV).(g) Star rating. (h) Some of the requirements for energy label validity.(i) The performance criteria for energy labelling approval.(j) A pro-forma application form. (k) Printing requirements for room airconditioner appliance energy labels.

    General Product Information - (Show below) - (Hide below)

    Committee EL-034
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes

    History - (Show below) - (Hide below)

    Under Revision See DR 02030 CP First published in Australia as AS 2279.1-1979.Second edition 1991.Jointly revised and redesignated AS/NZS 61000.3.2:1998. First published in Australia as AS 2279.1-1979. Second edition 1991. Jointly revised and redesignated AS/NZS 61000.3.2:1998.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1127.6-1990 Sound system equipment - Amplifiers
    AS/NZS 3250:1995 Approval and test specification - Mains operated electronic and related equipment for household and similar general use
    AS 1852.131-1988 International electrotechnical vocabulary - Electric and magnetic circuits
    AS/NZS 3350.2.7:1995 Safety of household and similar electrical appliances Particular requirements - Washing machines
    AS 1173.1-1979 Recommended methods of measurement on receivers for television broadcast transmissions - General considerations - Electrical measurements other than those at audio-frequencies

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 61000.3.6:2001 Electromagnetic compatibility (EMC) Limits - Assessment of emission limits for distorting loads in MV and HV power systems (IEC 61000-3-6:1996, MOD)
    AS/NZS 60923:1998 Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements (Reconfirmed 2013)
    AS 60146.1.1-2002 Semiconductor converters General requirements and line commutated converters - Specifications of basic requirements
    AS/NZS 61000.4.7:1999 Electromagnetic compatibility (EMC) Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
    AS/NZS 60929:2000 Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
    AS/NZS 3947.2:2002 Low-voltage switchgear and controlgear Circuit-breakers
    AS 1418.1-2002 Cranes, hoists and winches General requirements
    AS/NZS 3947.4.2:2000 Low-voltage switchgear and controlgear Contactors and motor-starters - A.C. semiconductor motor controllers and starters
    AS 61800.3-2001 Adjustable speed electrical power drive systems - EMC product standard including specific test methods
    AS/NZS 61000.3.5:1998 Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 16 A
    AS/NZS 61558.1:2000 Safety of power transformers, power supply units and similar General requirements and tests (IEC 61558-1 Ed 1.1, MOD)
    AS/NZS 3947.4.3:2000 Low-voltage switchgear and controlgear Contactors and motor-starters - A.C. semiconductor controllers and contactors for non-motor loads
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective