• AS/NZS 61241.1.1:1999

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electrical apparatus for use in the presence of combustible dust Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  01-08-2017

    Language(s):  English

    Published date:  05-12-1999

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 61241.1.1:1999 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - ELECTRICAL APPARATUS PROTECTED BY...
    4 - PREFACE
    5 - CONTENTS
    6 - INTRODUCTION
    7 - 1 Scope
    7 - 2 Normative references
    9 - 3 Definitions
    9 - 3.1 dust
    9 - 3.2 combustible dust
    9 - 3.3 conductive dust
    9 - 3.4 explosive dust atmosphere
    9 - 3.5 minimum ignition temperature of a dust layer
    9 - 3.6 minimum ignition temperature of a dust cloud
    10 - 3.7 dust ignition protection (DIP)
    10 - 3.8 dust-tight enclosure
    10 - 3.9 dust-protected enclosure
    10 - 3.10 maximum surface temperature
    10 - 3.11 maximum permissible surface temperature
    10 - 3.12 zones
    10 - 3.13 zone 20
    10 - 3.14 zone 21
    10 - 3.15 zone 22
    10 - 4 Construction
    11 - 5 Enclosure materials
    11 - 5.1 Non-metallic enclosures and non-metallic parts of enclosures
    12 - 5.2 Enclosures containing light metals
    12 - 6 Fasteners
    13 - 7 Interlocking devices
    13 - 8 Bushings
    13 - 9 Materials used for cementing
    13 - 10 Connection facilities and terminal compartments
    13 - 11 Connection facilities for earthing or bonding conductors
    14 - 12 Cable and conduit entries
    16 - 13 Supplementary requirements for electrical apparatus for practice B for use in zone 20 or 21
    16 - 13.1 Joints
    17 - 13.2 Operating rods, spindles or shafts
    18 - 13.3 Clearance of bolts
    18 - 14 Rotating electrical machines
    18 - 14.1
    19 - 14.2
    19 - 14.3
    19 - 14.4Construction and mounting of the ventilating systems
    19 - 14.5Clearances for the ventilating system for use in zone 20 or 21
    19 - 14.6 Materials for external fans and fanhoods for use in zone 20 or 21
    19 - 15 Switchgear
    20 - 16 Fuses
    20 - 17 Plugs and sockets
    20 - 18 Luminaires
    21 - 19 Caplights, caplamps and handlamps
    21 - 20 Verification and tests
    21 - 20.1 General
    22 - 20.2 Verification of documents
    22 - 20.3 Compliance of prototype or sample with documents
    23 - 20.4 Type tests
    23 - 20.4.1 General
    23 - 20.4.2 Mechanical tests
    25 - 20.4.3 Tests for dust exclusion by enclosures
    26 - 20.4.4 Torque test for bushings in enclosures for use in zone 20 or 21
    27 - 20.4.5 Thermal tests
    28 - 20.4.6 Thermal shock test
    28 - 20.4.7 Tests of non-metallic enclosures or of non-metallic parts of enclosures for use in zone 20 or 21
    30 - 21 Routine verifications and tests
    30 - 22 Manufacturer's responsibility
    30 - 23 Verifications and tests on modified or repaired electrical apparatus
    30 - 24 Clamping tests of non-armoured and braided cables
    30 - 24.1 Cable entries with clamping by the sealing ring
    31 - 24.2 Cable entries with clamping by filling compound
    31 - 24.3 Cable entries with clamping by means of a clamping device
    32 - 24.4 Tensile test
    32 - 24.5 Mechanical strength
    32 - 25 Clamping tests of armoured cables
    32 - 25.1 Clamping tests where the armourings are clamped by a device within the gland
    32 - 25.1.1 General
    33 - 25.1.2 Tensile test
    33 - 25.1.3 Mechanical strength
    33 - 25.2 Clamping tests where the armourings are not clamped by a device within the gland
    33 - 26 Marking
    33 - 26.1 General
    33 - 26.2 Markings
    33 - 26.2.1 Marking of all electrical apparatus
    33 - 26.2.2 Supplementary marking of apparatus for practice A
    34 - 26.2.3 Supplementary marking of apparatus for practice B
    35 - 27 Examples of marking
    35 - 27.1 Practice A
    35 - 27.1.1 Marking for zone 21
    35 - 27.1.2 Marking for zone 22
    35 - 27.2 Practice B
    35 - 27.2.1 Marking for zone 21
    35 - 27.2.2 Marking for zone 22

    Abstract - (Show below) - (Hide below)

    Specifies requirements for the design, construction and testing of electrical apparatus for use in areas where combustible dusts are or may be present, in quantities which could lead to a fire or explosion hazard. It is identical to and has been reproduced from IEC 61241-1-1:1999.

    Scope - (Show below) - (Hide below)

    This part of AS/NZS 61241 is applicable to electrical apparatus protected by enclosures and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. It specifies requirements for design, construction and testing of electrical apparatus.NOTE AS/NZS 61241.1.2 gives guidance on the selection, installation and maintenance of the apparatus. Apparatus within the scope of this standard may also be subject to additional requirements in other standards for example, IEC 60079-0.The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and other surfaces which could be in contact with dust and on the restriction of dust ingress into the enclosure by the use of "dust-tight" or "dust-protected" enclosures.The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures.Where the apparatus has to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional methods of protection may be necessary. The method used is not to adversely affect the integrity of the enclosure.The principles of this standard may also be followed when combustible fibres or flyings cause a hazard.This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances.This standard is not applicable to electrical apparatus intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by fire damp and/or combustible dust. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust.This standard does not include other types of protection and is only applicable to protection by enclosures and surface temperature limitation.

    General Product Information - (Show below) - (Hide below)

    Committee EL-014
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS C358-1965.Revised and redesignated as AS 2236-1979.Second edition 1982.Third edition 1985.Fourth edition 1994.Jointly revised and redesignated as AS/NZS 61241-1-1:1999. First published as AS C358-1965. Revised and redesignated as AS 2236-1979. Second edition 1982. Third edition 1985. Fourth edition 1994. Jointly revised and redesignated as AS/NZS 61241-1-1:1999.

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 61241.14:2005 Electrical apparatus for use in the presence of combustible dust Selection and installation (IEC 61241-14, Ed.1.0(2004) MOD)
    AS 1735.1-2001 Lifts, escalators and moving walks - General requirements
    AS/NZS 61241.4:2002 Electrical apparatus for use in the presence of combustible dust Type of protection 'pD'
    AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance - General requirements
    AS/NZS 4783.2:2002 Performance of electrical lighting equipment - Ballasts for fluorescent lamps Energy labelling and minimum energy performance standards requirements (Reconfirmed 2013)
    HB 13-2000 Electrical equipment for hazardous areas
    AS 1735.1-2003 Lifts, escalators and moving walks General requirements
    AS/NZS 61241.1.2:2000 Electrical apparatus for use in the presence of combustible dust Electrical apparatus protected by enclosures and surface temperature limitation - Selection, installation and maintenance
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective