• AS/NZS 61347.1:2002

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Lamp controlgear General and safety requirements (IEC 61347-1:2000, MOD)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  20-06-2023

    Language(s):  English

    Published date:  27-08-2002

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Specifies electrical safety requirements for lamp controlgear for use in d.c. supplies up to 250 volt and a.c. supplies up to 1000 V. This Standard is reproduced from IEC 61347-1:2000 and varied to suit Australian/New Zealand conditions.

    Scope - (Show below) - (Hide below)

    This part of AS/NZS 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.This standard also covers lamp controlgear for lamps which are not yet standardized.Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included.Requirements for semi-luminaires are given in AS/NZS 60598.1.In addition to the requirements given in this standard, annex B sets out general and safety requirements applicable to thermally protected lamp controlgear.Annex C sets out additional general and safety requirements as they apply to electronic lamp controlgear with means of protection against overheating.NOTE – Examples of products covered by this Standard are electronic starters, ballasts and electronic converters. Dimmers, iron core transformers (if not covered by 61347.2) are not included in this Standard.

    General Product Information - (Show below) - (Hide below)

    Committee EL-041
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS/NZS 61347.1:2002.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 60598.1:2001 Luminaires General requirements and tests (IEC 60598.1:1996, MOD)
    AS/NZS 60695.2.10:2001 Glowing/hot wire based test methods Glow-wire apparatus and common test procedure
    AS/NZS 60921:2002 Ballasts for tubular fluorescent lamps - Performance requirements (Reconfirmed 2019)
    AS/NZS 4695.2.2:1996 Fire hazard testing of electrotechnical products Test methods - Needle-flame test

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 1158.6:2010 Lighting for roads and public spaces Luminaires
    AS/NZS IEC 61347.2.13:2013 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (IEC 61347-2-13, Ed.1.0 (2006) MOD)
    AS/NZS 60929:2005 A.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements (Reconfirmed 2016)
    AS/NZS 61347.2.5:2002 Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for public transport
    AS/NZS 61347.2.10:2004 Lamp controlgear Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2000 MOD)
    AS/NZS 61347.2.6:2002 Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for aircraft lighting
    AS/NZS 61347.2.2:2004 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2:2000 MOD)
    AS/NZS 4879.2:2010 Performance of transformers and electronic step-down convertors for ELV lamps Minimum Energy Performance Standards (MEPS) requirements (Reconfirmed 2020)
    AS/NZS 4879.2(INT):2008 Performance of transformers and electronic step-down convertors for ELV lamps Minimum Energy Performance Standards (MEPS) requirements
    AS/NZS 60598.2.22:2005 Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD)
    AS/NZS 4879.1:2008 Performance of transformers and electronic step-down convertors for ELV lamps Test method - Energy performance (Reconfirmed 2017)
    AS/NZS 61347.2.9:2004 Lamp controlgear Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) (IEC 61347-2-9:2000 MOD)
    AS/NZS 60925:2005 D.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements (IEC 60925, Ed. 1.2 (2001) MOD)
    AS/NZS 61347.2.11:2003 Lamp controlgear Particular requirements for miscellaneous electronic circuits used with luminaires (IEC 61347-2-11:2001 MOD) (Reconfirmed 2016)
    AS/NZS 61347.2.8:2003 Lamp controlgear Particular requirements for ballasts for fluorescent lamps (IEC 61347-2-8:2000, MOD) (Reconfirmed 2019)
    AS/NZS 61347.2.2:2007 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2, Ed. 1.2 (2006) MOD)
    AS/NZS 61347.2.3:2004 Lamp controlgear Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps (IEC 61347-2-3:2000, MOD)
    AS/NZS 60927:2005 Auxiliaries for lamps - Starting devices (other than glow starters) - Performance requirements (IEC 60927, Ed.2.2 (2004) MOD)
    AS/NZS 1158.6:2004 Lighting for roads and public spaces Luminaires
    AS/NZS 61347.2.1:2002 Lamp controlgear Particular requirements for starting devices (other than glow starters)
    AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
    AS/NZS 61347.2.4:2002 Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for general lighting
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective