AS/NZS IEC 60331.1:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Tests for electric cables under fire conditions - Circuit integrity Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
21-01-2021
English
01-05-2017
Adopts IEC60331-1:2009 to specify the performance requirements and test method for low voltage power cables of rated voltage up to and including 0.6/1.0kV and control cables with a rated voltage under fire conditions.
Committee |
EL-003
|
DevelopmentNote |
Under Revision by DR AS/NZS IEC 60331.1:2020.
|
DocumentType |
Standard
|
ISBN |
978-1-76035-730-6
|
Pages |
18
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This part of IEC 60331 specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. It is intended for use when testing cables of greater than 20 mm overall diameter.NOTE 1 Cables of smaller diameter should be tested using the apparatus, procedure and requirements of IEC 60331-2.This standard describes the means of test specimen preparation, the continuity checking arrangements, the electrical testing procedure, the method of burning the cables and the method of shock production, and gives requirements for evaluating test results.NOTE 2 Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure may be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 3,3 kV, provided that suitable fuses are used.Annex A provides the method of verification of the burner and control system used for the test.Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this standard.
Standards | Relationship |
IEC 60331-1:2009 | Identical |
Originated as part of AS/NZS 1660.5.5:1998;Previous edition AS/NZS 1660.5.5:2005;Jointly revised in part and redesignated as AS/NZS IEC 60331.1:2017.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.