AS/NZS IEC 60332.3.21:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Tests on electric cables under fire conditions, Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
21-08-2023
English
30-06-2017
The objective of this Standard is to specify method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. This Standard specifies Category A F/R and relates only to power cables of conductor cross-sectional area greater than 35 mm2 installed on the test ladder in a spaced configuration on the front and rear to achieve a nominal total volume of non-metallic material of 7 l/m of test sample.
Committee |
EL-003
|
DevelopmentNote |
Under Revision by DR AS/NZS IEC 60332.3.21:2021.
|
DocumentType |
Standard
|
ISBN |
978 1 76035 828 0
|
Pages |
8
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
The series of International Standards covered by Parts 3-10, 3-21, 3-22, 3-23, 3-24 and 3-25 of IEC 60332 specifies methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.NOTE For the purpose of this standard the term "electric wire or cable" covers all insulated metallic conductor cables used for the conveyance of energy or signals.The test is intended for type approval testing. The requirements for the selection of cables for testing are given in annex A. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable’s ability to limit flame spread.This part of IEC 60332 covers category A F/R and relates only to power cables of conductor cross-sectional area greater than 35 mm² installed on the test ladder in a spaced configuration on the front and rear to achieve a nominal total volume of non-metallic material of 7 l/m of test sample. The flame application time is 40 min. This method of mounting is intended for special cable designs used in particular installations when required in the cable specification. Category A F/R is not intended for general use.A recommended performance requirement is given in annex B.
Standards | Relationship |
IEC 60332-3-21:2000 | Identical |
Originated in Australia as SAA Int 88001-1988.
Jointly revised and designated as AS/NZS 1660.5.1:1998.
Third edition 2005.
AS/NZS 1660.5.1:2005 revised and redesignated, in part, as AS/NZS IEC 60332.3.21:2017.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.